{"id":{"repo_id":"greece","oai_identifier":"oai:10442/2467"},"canonical_url":"https://search.ndltd.org/etd/greece/oai:10442/2467","repository":{"repo_id":"greece","name":"Greek National Archive of PhD Theses","base_url":"https://phdtheses.ekt.gr/eadd_oai/request"},"display":{"title":"ΣΥΓΚΡΙΤΙΚΗ ΙΣΤΟΛΟΓΙΚΗ ΜΕΛΕΤΗ ΤΗΣ ΒΙΟΣΥΜΒΑΤΟΤΗΤΑΣ ΤΡΙΩΝ ΚΕΡΑΜΙΚΩΝ ΥΛΙΚΩΝ ΕΜΦΥΤΕΥΜΕΝΩΝ ΣΤΟ ΠΕΡΙΟΔΟΝΤΙΟ","abstract":"THE AIM OF THIS STUDY WAS TO INVESTIGATE THE BIOCOMPATIBILITY AND THE SIZE OF THE INDIVIDUAL CRYSTALS CONSISTING THE PARTICLES OF THE BIOCERAMICS SYNTHOGRAFT R, BIOAPATITE R AND MICROSIZED HYDROXYAPATITE IMPLANTED IN INFRABONY PERIODONTAL DEFECTS IN HUMAN, UNDER THE TRANSMISSION ELECTRON MICROSCOPE. BY X-RAY DIFFRACTION STUDIES HAS BEEN VERIFIED THAT SYNTHOGRAFT IS MADE OF B-TRICALCIUM PHOSPHATE AND THE OTHER TWO OF HYDROXYAPATITE. THE THREE BIOMATERIALS TESTED ARE WELL TOLERATED BY THE TISSUES, THEY DO NOT INDUCE INFLAMMATION AND THEY ARE ABSOLUTELY BIOCOMPATIBLE. ALL THREE MATERIALS ARE SURROUNDED BY NEW BONE, BUT MICROSIZED HYDROXYAPATITE IS MORE EFFICIENT FOR BONE FORMATION AND THIS IS PROBABLY ASSOCIATED WITH THE SMALLEST SIZE OF ITS PARTICLE CRYSTALS.","abstract_html":"THE AIM OF THIS STUDY WAS TO INVESTIGATE THE BIOCOMPATIBILITY AND THE SIZE OF THE INDIVIDUAL CRYSTALS CONSISTING THE PARTICLES OF THE BIOCERAMICS SYNTHOGRAFT R, BIOAPATITE R AND MICROSIZED HYDROXYAPATITE IMPLANTED IN INFRABONY PERIODONTAL DEFECTS IN HUMAN, UNDER THE TRANSMISSION ELECTRON MICROSCOPE. BY X-RAY DIFFRACTION STUDIES HAS BEEN VERIFIED THAT SYNTHOGRAFT IS MADE OF B-TRICALCIUM PHOSPHATE AND THE OTHER TWO OF HYDROXYAPATITE. THE THREE BIOMATERIALS TESTED ARE WELL TOLERATED BY THE TISSUES, THEY DO NOT INDUCE INFLAMMATION AND THEY ARE ABSOLUTELY BIOCOMPATIBLE. ALL THREE MATERIALS ARE SURROUNDED BY NEW BONE, BUT MICROSIZED HYDROXYAPATITE IS MORE EFFICIENT FOR BONE FORMATION AND THIS IS PROBABLY ASSOCIATED WITH THE SMALLEST SIZE OF ITS PARTICLE CRYSTALS.","abstract_has_math":false,"creators":["Ζιώρης, Ηλίας"],"institution":"National and Kapodistrian University of Athens","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1992,"date_issued":"1992","date_published":"1992","updated_at":"2026-11-18T20:21:34Z","subjects":["Bioceramics","Biocompatibility","ELECTRONMICROSCOPE","Implants","Periodontium","X-ray diffraction","Βιοσυμβατότητα","Εμφυτεύματα","Ηλεκτρονικό μικροσκόπιο","Κεραμικά υλικά","Περίθλαση ακτίνων Χ","Περιοδόντιο","Ιατρική και Επιστήμες Υγείας","Κλινική Ιατρική","Medical and Health Sciences","Clinical Medicine"],"languages":["gre"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["10.12681/eadd/2467"],"render_values":[{"text":"10.12681/eadd/2467","href":"https://doi.org/10.12681/eadd/2467","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10442/hedi/2467","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/10442/hedi/2467","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://phdtheses.ekt.gr/eadd_oai/request?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3A10442%2F2467","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Ζιώρης, Ηλίας"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1992"]},{"key":"dc:publisher","label":"Institution","values":["National and Kapodistrian University of Athens","Εθνικό και Καποδιστριακό Πανεπιστήμιο Αθηνών (ΕΚΠΑ)"]},{"key":"dc:type","label":"Dc Type","values":["PhD Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Bioceramics","Biocompatibility","ELECTRONMICROSCOPE","Implants","Periodontium","X-ray diffraction","Βιοσυμβατότητα","Εμφυτεύματα","Ηλεκτρονικό μικροσκόπιο","Κεραμικά υλικά","Περίθλαση ακτίνων Χ","Περιοδόντιο","Ιατρική και Επιστήμες Υγείας","Κλινική Ιατρική","Medical and Health Sciences","Clinical Medicine"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["gre"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.12681/eadd/2467","http://hdl.handle.net/10442/hedi/2467"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["THE AIM OF THIS STUDY WAS TO INVESTIGATE THE BIOCOMPATIBILITY AND THE SIZE OF THE INDIVIDUAL CRYSTALS CONSISTING THE PARTICLES OF THE BIOCERAMICS SYNTHOGRAFT R, BIOAPATITE R AND MICROSIZED HYDROXYAPATITE IMPLANTED IN INFRABONY PERIODONTAL DEFECTS IN HUMAN, UNDER THE TRANSMISSION ELECTRON MICROSCOPE. BY X-RAY DIFFRACTION STUDIES HAS BEEN VERIFIED THAT SYNTHOGRAFT IS MADE OF B-TRICALCIUM PHOSPHATE AND THE OTHER TWO OF HYDROXYAPATITE. THE THREE BIOMATERIALS TESTED ARE WELL TOLERATED BY THE TISSUES, THEY DO NOT INDUCE INFLAMMATION AND THEY ARE ABSOLUTELY BIOCOMPATIBLE. ALL THREE MATERIALS ARE SURROUNDED BY NEW BONE, BUT MICROSIZED HYDROXYAPATITE IS MORE EFFICIENT FOR BONE FORMATION AND THIS IS PROBABLY ASSOCIATED WITH THE SMALLEST SIZE OF ITS PARTICLE CRYSTALS.","ΣΤΗΝ ΕΡΓΑΣΙΑ ΑΥΤΗ ΜΕΛΕΤΗΘΗΚΕ ΣΤΟ ΗΛΕΚΤΡΟΝΙΚΟ ΜΙΚΡΟΣΚΟΠΙΟ ΔΙΑΒΙΒΑΣΕΩΣ Η ΒΙΟΣΥΜΒΑΤΟΤΗΤΑ ΚΑΙ ΤΟ ΜΕΓΕΘΟΣ ΤΩΝ ΚΡΥΣΤΑΛΛΙΚΩΝ ΚΟΚΚΙΩΝ ΤΩΝ ΚΕΡΑΜΙΚΩΝ ΥΛΙΚΩΝ SYNTHOGRAFT R, BIOAPATITE R ΚΑΙ MICROSIZED HYDROXYAPATITE (MH) ΚΑΘΩΣ ΚΑΙ Η ΙΚΑΝΟΤΗΤΑ ΤΟΥΣ ΓΙΑ ΣΧΗΜΑΤΙΣΜΟ ΟΣΤΟΥ, ΟΤΑΝ ΕΜΦΥΤΕΥΟΝΤΑΙ ΣΕ ΑΝΘΡΩΠΙΝΕΣ ΕΝΔΟΟΣΤΙΚΕΣ ΠΕΡΙΟΔΟΝΤΙΚΕΣ ΒΛΑΒΕΣ. ΜΕ ΤΗ ΜΕΘΟΔΟ ΤΗΣ ΠΕΡΙΘΛΑΣΗΣ ΤΩΝ ΑΚΤΙΝΩΝ Χ ΕΞΑΚΡΙΒΩΘΗΚΕ ΟΤΙ ΤΟΠΡΩΤΟ ΑΠΟΤΕΛΕΙΤΑΙ ΑΠΟ Β-ΦΩΣΦΟΡΙΚΟ ΤΡΙΑΣΒΕΣΤΙΟ ΕΝΩ ΤΑ ΑΛΛΑ ΔΥΟ ΑΠΟ ΥΔΡΟΞΥΑΠΑΤΙΤΗ ΚΑΙ ΤΑ ΤΡΙΑ ΕΙΝΑΙ ΚΑΛΑ ΑΝΕΚΤΑ ΑΠΟ ΤΟΥΣ ΙΣΤΟΥΣ, ΔΕΝ ΠΡΟΚΑΛΟΥΝ ΦΛΕΓΜΟΝΗ ΚΑΙΕΙΝΑΙ ΒΙΟΣΥΜΒΑΤΑ. ΓΥΡΩ ΑΠΟ ΚΑΘΕ ΥΛΙΚΟ ΣΧΗΜΑΤΙΖΕΤΑΙ ΝΕΟ ΟΣΤΟΥΝ, ΕΝΩ ΤΟ ΜΗ ΦΑΙΝΕΤΑΙ ΑΠΟΤΕΛΕΣΜΑΤΙΚΟΤΕΡΟ, ΙΣΩΣ ΛΟΓΩ ΤΟΥ ΜΙΚΡΟΤΕΡΟΥ ΜΕΓΕΘΟΥΣ ΤΩΝ ΚΡΥΣΤΑΛΛΙΚΩΝ ΤΟΥ ΚΟΚΚΙΩΝ."]},{"key":"dc:title","label":"Title","values":["ΣΥΓΚΡΙΤΙΚΗ ΙΣΤΟΛΟΓΙΚΗ ΜΕΛΕΤΗ ΤΗΣ ΒΙΟΣΥΜΒΑΤΟΤΗΤΑΣ ΤΡΙΩΝ ΚΕΡΑΜΙΚΩΝ ΥΛΙΚΩΝ ΕΜΦΥΤΕΥΜΕΝΩΝ ΣΤΟ ΠΕΡΙΟΔΟΝΤΙΟ","COMPARATIVE HISTOLOGICAL STUDY OF THE BIOCOMPATIBILITY OF THREE BIOCERAMICS IMPLANTED IN THE PERIODONTIUM"]}]}],"canonical_facts":{"dc:creator":["Ζιώρης, Ηλίας"],"dc:date":["1992"],"dc:description":["THE AIM OF THIS STUDY WAS TO INVESTIGATE THE BIOCOMPATIBILITY AND THE SIZE OF THE INDIVIDUAL CRYSTALS CONSISTING THE PARTICLES OF THE BIOCERAMICS SYNTHOGRAFT R, BIOAPATITE R AND MICROSIZED HYDROXYAPATITE IMPLANTED IN INFRABONY PERIODONTAL DEFECTS IN HUMAN, UNDER THE TRANSMISSION ELECTRON MICROSCOPE. BY X-RAY DIFFRACTION STUDIES HAS BEEN VERIFIED THAT SYNTHOGRAFT IS MADE OF B-TRICALCIUM PHOSPHATE AND THE OTHER TWO OF HYDROXYAPATITE. THE THREE BIOMATERIALS TESTED ARE WELL TOLERATED BY THE TISSUES, THEY DO NOT INDUCE INFLAMMATION AND THEY ARE ABSOLUTELY BIOCOMPATIBLE. ALL THREE MATERIALS ARE SURROUNDED BY NEW BONE, BUT MICROSIZED HYDROXYAPATITE IS MORE EFFICIENT FOR BONE FORMATION AND THIS IS PROBABLY ASSOCIATED WITH THE SMALLEST SIZE OF ITS PARTICLE CRYSTALS.","ΣΤΗΝ ΕΡΓΑΣΙΑ ΑΥΤΗ ΜΕΛΕΤΗΘΗΚΕ ΣΤΟ ΗΛΕΚΤΡΟΝΙΚΟ ΜΙΚΡΟΣΚΟΠΙΟ ΔΙΑΒΙΒΑΣΕΩΣ Η ΒΙΟΣΥΜΒΑΤΟΤΗΤΑ ΚΑΙ ΤΟ ΜΕΓΕΘΟΣ ΤΩΝ ΚΡΥΣΤΑΛΛΙΚΩΝ ΚΟΚΚΙΩΝ ΤΩΝ ΚΕΡΑΜΙΚΩΝ ΥΛΙΚΩΝ SYNTHOGRAFT R, BIOAPATITE R ΚΑΙ MICROSIZED HYDROXYAPATITE (MH) ΚΑΘΩΣ ΚΑΙ Η ΙΚΑΝΟΤΗΤΑ ΤΟΥΣ ΓΙΑ ΣΧΗΜΑΤΙΣΜΟ ΟΣΤΟΥ, ΟΤΑΝ ΕΜΦΥΤΕΥΟΝΤΑΙ ΣΕ ΑΝΘΡΩΠΙΝΕΣ ΕΝΔΟΟΣΤΙΚΕΣ ΠΕΡΙΟΔΟΝΤΙΚΕΣ ΒΛΑΒΕΣ. ΜΕ ΤΗ ΜΕΘΟΔΟ ΤΗΣ ΠΕΡΙΘΛΑΣΗΣ ΤΩΝ ΑΚΤΙΝΩΝ Χ ΕΞΑΚΡΙΒΩΘΗΚΕ ΟΤΙ ΤΟΠΡΩΤΟ ΑΠΟΤΕΛΕΙΤΑΙ ΑΠΟ Β-ΦΩΣΦΟΡΙΚΟ ΤΡΙΑΣΒΕΣΤΙΟ ΕΝΩ ΤΑ ΑΛΛΑ ΔΥΟ ΑΠΟ ΥΔΡΟΞΥΑΠΑΤΙΤΗ ΚΑΙ ΤΑ ΤΡΙΑ ΕΙΝΑΙ ΚΑΛΑ ΑΝΕΚΤΑ ΑΠΟ ΤΟΥΣ ΙΣΤΟΥΣ, ΔΕΝ ΠΡΟΚΑΛΟΥΝ ΦΛΕΓΜΟΝΗ ΚΑΙΕΙΝΑΙ ΒΙΟΣΥΜΒΑΤΑ. ΓΥΡΩ ΑΠΟ ΚΑΘΕ ΥΛΙΚΟ ΣΧΗΜΑΤΙΖΕΤΑΙ ΝΕΟ ΟΣΤΟΥΝ, ΕΝΩ ΤΟ ΜΗ ΦΑΙΝΕΤΑΙ ΑΠΟΤΕΛΕΣΜΑΤΙΚΟΤΕΡΟ, ΙΣΩΣ ΛΟΓΩ ΤΟΥ ΜΙΚΡΟΤΕΡΟΥ ΜΕΓΕΘΟΥΣ ΤΩΝ ΚΡΥΣΤΑΛΛΙΚΩΝ ΤΟΥ ΚΟΚΚΙΩΝ."],"dc:identifier":["10.12681/eadd/2467","http://hdl.handle.net/10442/hedi/2467"],"dc:language":["gre"],"dc:publisher":["National and Kapodistrian University of Athens","Εθνικό και Καποδιστριακό Πανεπιστήμιο Αθηνών (ΕΚΠΑ)"],"dc:subject":["Bioceramics","Biocompatibility","ELECTRONMICROSCOPE","Implants","Periodontium","X-ray diffraction","Βιοσυμβατότητα","Εμφυτεύματα","Ηλεκτρονικό μικροσκόπιο","Κεραμικά υλικά","Περίθλαση ακτίνων Χ","Περιοδόντιο","Ιατρική και Επιστήμες Υγείας","Κλινική Ιατρική","Medical and Health Sciences","Clinical Medicine"],"dc:title":["ΣΥΓΚΡΙΤΙΚΗ ΙΣΤΟΛΟΓΙΚΗ ΜΕΛΕΤΗ ΤΗΣ ΒΙΟΣΥΜΒΑΤΟΤΗΤΑΣ ΤΡΙΩΝ ΚΕΡΑΜΙΚΩΝ ΥΛΙΚΩΝ ΕΜΦΥΤΕΥΜΕΝΩΝ ΣΤΟ ΠΕΡΙΟΔΟΝΤΙΟ","COMPARATIVE HISTOLOGICAL STUDY OF THE BIOCOMPATIBILITY OF THREE BIOCERAMICS IMPLANTED IN THE PERIODONTIUM"],"dc:type":["PhD Thesis"]},"updated_at":"2026-11-18T20:21:34Z"}