{"id":{"repo_id":"greece","oai_identifier":"oai:10442/25671"},"canonical_url":"https://search.ndltd.org/etd/greece/oai:10442/25671","repository":{"repo_id":"greece","name":"Greek National Archive of PhD Theses","base_url":"https://phdtheses.ekt.gr/eadd_oai/request"},"display":{"title":"Πειραματικός και υπολογιστικός καθορισμός της έκθεσης ανθρώπων σε ηλεκτρικά και μαγνητικά πεδία","abstract":"In this thesis constitutes a contribution to the experimental and calculating determination of human exposure to electric and magnetic fields generated by power systems equipments (overhead transmission lines underground cables transformers substations). The field intensities in the vicinity of substations are mainly determined with measurements, because their calculation is practically very difficult due to the complexity of the electrical equipment. In double circuit overhead transmission lines and in high voltage underground cables (three-phase systems constituted by single-core cables) the phase configurations are determined m order to achieve the reduction of field intensities in areas accessible to people. The possibilities of measurements in 400kV grid are very restricted and apparently they cannot cover the needs of extensive parametrical investigations. In order to examine experimentally the effect of the theoretical investigations, a model of two parallel running 400kV double circuit lines was constructed at the Power Systems Laboratory of the University of Patras.","abstract_html":"In this thesis constitutes a contribution to the experimental and calculating determination of human exposure to electric and magnetic fields generated by power systems equipments (overhead transmission lines underground cables transformers substations). The field intensities in the vicinity of substations are mainly determined with measurements, because their calculation is practically very difficult due to the complexity of the electrical equipment. In double circuit overhead transmission lines and in high voltage underground cables (three-phase systems constituted by single-core cables) the phase configurations are determined m order to achieve the reduction of field intensities in areas accessible to people. The possibilities of measurements in 400kV grid are very restricted and apparently they cannot cover the needs of extensive parametrical investigations. In order to examine experimentally the effect of the theoretical investigations, a model of two parallel running 400kV double circuit lines was constructed at the Power Systems Laboratory of the University of Patras.","abstract_has_math":false,"creators":["Mimos, Evangelos","Μίμος, Ευάγγελος"],"institution":"University of Patras","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2009,"date_issued":"2009","date_published":"2009","updated_at":"2026-11-18T20:44:57Z","subjects":["Έκθεση σε ηλεκτρικά πεδία","Έκθεση σε μαγνητικά πεδία","Μοντέλο εναέριων γραμμών","Πεδία υπόγειων καλωδίων","Πεδία εναέριων γραμμών","Πεδία μετασχηματιστών","Πεδία υποσταθμών","Exposure to electric fields","Exposure to magnetic fields","Overhead power line model","Fields of underground cables","Fields of overhead power lines","Fields of transformers","Fields of substations","Επιστήμες Μηχανικού και Τεχνολογία","Επιστήμη Ηλεκτρολόγου Μηχανικού, Ηλεκτρονικού Μηχανικού, Μηχανικού Η/Υ","Engineering and Technology","Electrical Engineering, Electronic Engineering, Information Engineering"],"languages":["gre"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["10.12681/eadd/25671"],"render_values":[{"text":"10.12681/eadd/25671","href":"https://doi.org/10.12681/eadd/25671","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10442/hedi/25671","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/10442/hedi/25671","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://phdtheses.ekt.gr/eadd_oai/request?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3A10442%2F25671","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Mimos, Evangelos","Μίμος, Ευάγγελος"]},{"key":"dc:creator.fathername","label":"Dc Creator Fathername","values":["I."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2009"]},{"key":"dc:publisher","label":"Institution","values":["University of Patras","Πανεπιστήμιο Πατρών"]},{"key":"dc:type","label":"Dc Type","values":["PhD Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Έκθεση σε ηλεκτρικά πεδία","Έκθεση σε μαγνητικά πεδία","Μοντέλο εναέριων γραμμών","Πεδία υπόγειων καλωδίων","Πεδία εναέριων γραμμών","Πεδία μετασχηματιστών","Πεδία υποσταθμών","Exposure to electric fields","Exposure to magnetic fields","Overhead power line model","Fields of underground cables","Fields of overhead power lines","Fields of transformers","Fields of substations","Επιστήμες Μηχανικού και Τεχνολογία","Επιστήμη Ηλεκτρολόγου Μηχανικού, Ηλεκτρονικού Μηχανικού, Μηχανικού Η/Υ","Engineering and Technology","Electrical Engineering, Electronic Engineering, Information Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["gre"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.12681/eadd/25671","http://hdl.handle.net/10442/hedi/25671"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["In this thesis constitutes a contribution to the experimental and calculating determination of human exposure to electric and magnetic fields generated by power systems equipments (overhead transmission lines underground cables transformers substations). The field intensities in the vicinity of substations are mainly determined with measurements, because their calculation is practically very difficult due to the complexity of the electrical equipment. In double circuit overhead transmission lines and in high voltage underground cables (three-phase systems constituted by single-core cables) the phase configurations are determined m order to achieve the reduction of field intensities in areas accessible to people. The possibilities of measurements in 400kV grid are very restricted and apparently they cannot cover the needs of extensive parametrical investigations. In order to examine experimentally the effect of the theoretical investigations, a model of two parallel running 400kV double circuit lines was constructed at the Power Systems Laboratory of the University of Patras.","Η διατριβή αποτελεί μια συμβολή στον πειραματικό και υπολογιστικό καθορισμό της έκθεσης ανθρώπων σε ηλεκτρικά και μαγνητικά πεδία στοιχείων συστημάτων ηλεκτρικής ενέργειας (εναέριες γραμμές, καλώδια, μετασχηματιστές, υποσταθμοί). Οι πεδιακές εντάσεις στους υποσταθμούς προκύπτουν κυρίως από μετρήσεις, επειδή ο υπολογισμός τους είναι πρακτικά αδύνατος, λόγω των συνθέτων διατάξεων των υπό τάση στοιχείων. Στις εναέριες γραμμές διπλού κυκλώματος και στα υπόγεια καλώδια υψηλής τάσεως (συγκρότηση των τριφασικών συστημάτων από μονοπολικά καλώδια) καθορίζονται οι διατάξεις των αγωγών των φάσεων, ώστε να επιτυγχάνεται η ελαχιστοποίηση των πεδιακών εντάσεων σε θέσεις προσιτές σε ανθρώπους. Οι δυνατότητες μετρήσεων στο δίκτυο 400kV είναι πολύ περιορισμένες και προφανώς δεν μπορούν να καλύψουν τις ανάγκες εκτεταμένων παραμετρικών διερευνήσεων. Για την πειραματική επιβεβαίωση των αποτελεσμάτων των θεωρητικών διερευνήσεων κατασκευάστηκε στο Εργαστήριο Παράγωγης, Μεταφοράς Διανομής και Χρησιμοποιήσεως Ηλεκτρικής Ενέργειας του Πανεπιστήμιου Πατρών ένα μοντέλο δύο παράλληλα οδευουσών γραμμών 400kV."]},{"key":"dc:title","label":"Title","values":["Πειραματικός και υπολογιστικός καθορισμός της έκθεσης ανθρώπων σε ηλεκτρικά και μαγνητικά πεδία","Experimental and calculating assessment of human exposure to electric and magnetic fields"]}]}],"canonical_facts":{"dc:creator":["Mimos, Evangelos","Μίμος, Ευάγγελος"],"dc:creator.fathername":["I."],"dc:date":["2009"],"dc:description":["In this thesis constitutes a contribution to the experimental and calculating determination of human exposure to electric and magnetic fields generated by power systems equipments (overhead transmission lines underground cables transformers substations). The field intensities in the vicinity of substations are mainly determined with measurements, because their calculation is practically very difficult due to the complexity of the electrical equipment. In double circuit overhead transmission lines and in high voltage underground cables (three-phase systems constituted by single-core cables) the phase configurations are determined m order to achieve the reduction of field intensities in areas accessible to people. The possibilities of measurements in 400kV grid are very restricted and apparently they cannot cover the needs of extensive parametrical investigations. In order to examine experimentally the effect of the theoretical investigations, a model of two parallel running 400kV double circuit lines was constructed at the Power Systems Laboratory of the University of Patras.","Η διατριβή αποτελεί μια συμβολή στον πειραματικό και υπολογιστικό καθορισμό της έκθεσης ανθρώπων σε ηλεκτρικά και μαγνητικά πεδία στοιχείων συστημάτων ηλεκτρικής ενέργειας (εναέριες γραμμές, καλώδια, μετασχηματιστές, υποσταθμοί). Οι πεδιακές εντάσεις στους υποσταθμούς προκύπτουν κυρίως από μετρήσεις, επειδή ο υπολογισμός τους είναι πρακτικά αδύνατος, λόγω των συνθέτων διατάξεων των υπό τάση στοιχείων. Στις εναέριες γραμμές διπλού κυκλώματος και στα υπόγεια καλώδια υψηλής τάσεως (συγκρότηση των τριφασικών συστημάτων από μονοπολικά καλώδια) καθορίζονται οι διατάξεις των αγωγών των φάσεων, ώστε να επιτυγχάνεται η ελαχιστοποίηση των πεδιακών εντάσεων σε θέσεις προσιτές σε ανθρώπους. Οι δυνατότητες μετρήσεων στο δίκτυο 400kV είναι πολύ περιορισμένες και προφανώς δεν μπορούν να καλύψουν τις ανάγκες εκτεταμένων παραμετρικών διερευνήσεων. Για την πειραματική επιβεβαίωση των αποτελεσμάτων των θεωρητικών διερευνήσεων κατασκευάστηκε στο Εργαστήριο Παράγωγης, Μεταφοράς Διανομής και Χρησιμοποιήσεως Ηλεκτρικής Ενέργειας του Πανεπιστήμιου Πατρών ένα μοντέλο δύο παράλληλα οδευουσών γραμμών 400kV."],"dc:identifier":["10.12681/eadd/25671","http://hdl.handle.net/10442/hedi/25671"],"dc:language":["gre"],"dc:publisher":["University of Patras","Πανεπιστήμιο Πατρών"],"dc:subject":["Έκθεση σε ηλεκτρικά πεδία","Έκθεση σε μαγνητικά πεδία","Μοντέλο εναέριων γραμμών","Πεδία υπόγειων καλωδίων","Πεδία εναέριων γραμμών","Πεδία μετασχηματιστών","Πεδία υποσταθμών","Exposure to electric fields","Exposure to magnetic fields","Overhead power line model","Fields of underground cables","Fields of overhead power lines","Fields of transformers","Fields of substations","Επιστήμες Μηχανικού και Τεχνολογία","Επιστήμη Ηλεκτρολόγου Μηχανικού, Ηλεκτρονικού Μηχανικού, Μηχανικού Η/Υ","Engineering and Technology","Electrical Engineering, Electronic Engineering, Information Engineering"],"dc:title":["Πειραματικός και υπολογιστικός καθορισμός της έκθεσης ανθρώπων σε ηλεκτρικά και μαγνητικά πεδία","Experimental and calculating assessment of human exposure to electric and magnetic fields"],"dc:type":["PhD Thesis"]},"updated_at":"2026-11-18T20:44:57Z"}