{"id":{"repo_id":"greece","oai_identifier":"oai:10442/27876"},"canonical_url":"https://search.ndltd.org/etd/greece/oai:10442/27876","repository":{"repo_id":"greece","name":"Greek National Archive of PhD Theses","base_url":"https://phdtheses.ekt.gr/eadd_oai/request"},"display":{"title":"Η δραστηριότητα των εισπνευστικών μυών κατά την εκπνοή σε ασθενείς μετά από αορτοστεφανιαία παράκαμψη (bypass)","abstract":"In twelve anesthetized -paralyzed patients after coronary artery bypass graft surgery , flow(V̇ ), volume (V) and airway pressure (Paw) were measured. With airway occluded at endinspiration,Paw was measured when the patients relaxed their respiratory muscles. Dividingrelaxed Paw by tidal volume (VT), total respiratory system elastance (Ers) was obtained. Whilethe patients were still relaxed , the occlusion was released to obtain the V̇ -V relationship duringthe ensuing relaxed expiration. Under these conditions, the expiratory driving pressure is V×Ers,and thus the pressure-flow relationship of the system can be obtained. Similar measurementswere repeated during anesthesia without paralysis.Ers averaged 23,4±4,9 cmH2O×L-1 during anesthesia-paralysis and 19,8±4,9 cmH2O×L-1during anesthesia (p =0,002). The corresponding values of total Rrs were 10,09±3,90 and8,29±2,73 cm H2O×L-1×sec, respectively (p=0,08). These results indicate that Ers decreasessubstantially during anesthesia compared to anesthesia-paralysis in patients after coronary arterybypass graft surgery, whereas Rrs remains virtually unchanged. Changes in impedance due topliometric work done by the inspiratory muscles during relaxation were neglected.The first measurements of inspiratory muscle activity and related negative work duringspontaneous expiration in anesthetized patients after coronary artery bypass graft surgery is alsoprovided. Patients under investigation showed marked braking of expiratory flow by Pmusi.Themean time for Pmusi to decrease to 50 and 0 % amounted to 48,8± 27,0 msec and 1.968± 989msec, respectively. Average value for flow-resistive work amounted to 84,4±8,7 % of theelastic energy stored during inspiration.The remaining portion, used as negative inspiratorymuscle work, amounted to 15,6 ± 8,7 %.","abstract_html":"In twelve anesthetized -paralyzed patients after coronary artery bypass graft surgery , flow(V̇ ), volume (V) and airway pressure (Paw) were measured. With airway occluded at endinspiration,Paw was measured when the patients relaxed their respiratory muscles. Dividingrelaxed Paw by tidal volume (VT), total respiratory system elastance (Ers) was obtained. Whilethe patients were still relaxed , the occlusion was released to obtain the V̇ -V relationship duringthe ensuing relaxed expiration. Under these conditions, the expiratory driving pressure is V×Ers,and thus the pressure-flow relationship of the system can be obtained. Similar measurementswere repeated during anesthesia without paralysis.Ers averaged 23,4±4,9 cmH2O×L-1 during anesthesia-paralysis and 19,8±4,9 cmH2O×L-1during anesthesia (p =0,002). The corresponding values of total Rrs were 10,09±3,90 and8,29±2,73 cm H2O×L-1×sec, respectively (p=0,08). These results indicate that Ers decreasessubstantially during anesthesia compared to anesthesia-paralysis in patients after coronary arterybypass graft surgery, whereas Rrs remains virtually unchanged. Changes in impedance due topliometric work done by the inspiratory muscles during relaxation were neglected.The first measurements of inspiratory muscle activity and related negative work duringspontaneous expiration in anesthetized patients after coronary artery bypass graft surgery is alsoprovided. Patients under investigation showed marked braking of expiratory flow by Pmusi.Themean time for Pmusi to decrease to 50 and 0 % amounted to 48,8± 27,0 msec and 1.968± 989msec, respectively. Average value for flow-resistive work amounted to 84,4±8,7 % of theelastic energy stored during inspiration.The remaining portion, used as negative inspiratorymuscle work, amounted to 15,6 ± 8,7 %.","abstract_has_math":false,"creators":["Pappa, Christina","Παππά, Χριστίνα"],"institution":"National and Kapodistrian University of Athens","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012","date_published":"2012","updated_at":"2026-11-18T20:48:35Z","subjects":["Μηχανική αναπνευστικού","Δραστηριότητα εισπνευστικών μυών κατά την εκπνοή","Ολική ελαστικότητα αναπνευστικού","Ολικές αντιστάσεις αναπνευστικού","Καμπύλες ροής-όγκου","Respiratory mechanics","Post-inspiratory muscle activity","Total respiratory elastance","Total respiratory resistance","Flow-volume curves","Ιατρική και Επιστήμες Υγείας","Κλινική Ιατρική","Medical and Health Sciences","Clinical Medicine"],"languages":["gre"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["10.12681/eadd/27876"],"render_values":[{"text":"10.12681/eadd/27876","href":"https://doi.org/10.12681/eadd/27876","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10442/hedi/27876","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/10442/hedi/27876","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://phdtheses.ekt.gr/eadd_oai/request?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3A10442%2F27876","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Pappa, Christina","Παππά, Χριστίνα"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2012"]},{"key":"dc:publisher","label":"Institution","values":["National and Kapodistrian University of Athens","Εθνικό και Καποδιστριακό Πανεπιστήμιο Αθηνών (ΕΚΠΑ)"]},{"key":"dc:type","label":"Dc Type","values":["PhD Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Μηχανική αναπνευστικού","Δραστηριότητα εισπνευστικών μυών κατά την εκπνοή","Ολική ελαστικότητα αναπνευστικού","Ολικές αντιστάσεις αναπνευστικού","Καμπύλες ροής-όγκου","Respiratory mechanics","Post-inspiratory muscle activity","Total respiratory elastance","Total respiratory resistance","Flow-volume curves","Ιατρική και Επιστήμες Υγείας","Κλινική Ιατρική","Medical and Health Sciences","Clinical Medicine"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["gre"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.12681/eadd/27876","http://hdl.handle.net/10442/hedi/27876"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["In twelve anesthetized -paralyzed patients after coronary artery bypass graft surgery , flow(V̇ ), volume (V) and airway pressure (Paw) were measured. With airway occluded at endinspiration,Paw was measured when the patients relaxed their respiratory muscles. Dividingrelaxed Paw by tidal volume (VT), total respiratory system elastance (Ers) was obtained. Whilethe patients were still relaxed , the occlusion was released to obtain the V̇ -V relationship duringthe ensuing relaxed expiration. Under these conditions, the expiratory driving pressure is V×Ers,and thus the pressure-flow relationship of the system can be obtained. Similar measurementswere repeated during anesthesia without paralysis.Ers averaged 23,4±4,9 cmH2O×L-1 during anesthesia-paralysis and 19,8±4,9 cmH2O×L-1during anesthesia (p =0,002). The corresponding values of total Rrs were 10,09±3,90 and8,29±2,73 cm H2O×L-1×sec, respectively (p=0,08). These results indicate that Ers decreasessubstantially during anesthesia compared to anesthesia-paralysis in patients after coronary arterybypass graft surgery, whereas Rrs remains virtually unchanged. Changes in impedance due topliometric work done by the inspiratory muscles during relaxation were neglected.The first measurements of inspiratory muscle activity and related negative work duringspontaneous expiration in anesthetized patients after coronary artery bypass graft surgery is alsoprovided. Patients under investigation showed marked braking of expiratory flow by Pmusi.Themean time for Pmusi to decrease to 50 and 0 % amounted to 48,8± 27,0 msec and 1.968± 989msec, respectively. Average value for flow-resistive work amounted to 84,4±8,7 % of theelastic energy stored during inspiration.The remaining portion, used as negative inspiratorymuscle work, amounted to 15,6 ± 8,7 %."]},{"key":"dc:title","label":"Title","values":["Η δραστηριότητα των εισπνευστικών μυών κατά την εκπνοή σε ασθενείς μετά από αορτοστεφανιαία παράκαμψη (bypass)","Post-inspiratory muscle activity in anesthetized patients after coronary artery bypass graft surgery (CABG)"]}]}],"canonical_facts":{"dc:creator":["Pappa, Christina","Παππά, Χριστίνα"],"dc:date":["2012"],"dc:description":["In twelve anesthetized -paralyzed patients after coronary artery bypass graft surgery , flow(V̇ ), volume (V) and airway pressure (Paw) were measured. With airway occluded at endinspiration,Paw was measured when the patients relaxed their respiratory muscles. Dividingrelaxed Paw by tidal volume (VT), total respiratory system elastance (Ers) was obtained. Whilethe patients were still relaxed , the occlusion was released to obtain the V̇ -V relationship duringthe ensuing relaxed expiration. Under these conditions, the expiratory driving pressure is V×Ers,and thus the pressure-flow relationship of the system can be obtained. Similar measurementswere repeated during anesthesia without paralysis.Ers averaged 23,4±4,9 cmH2O×L-1 during anesthesia-paralysis and 19,8±4,9 cmH2O×L-1during anesthesia (p =0,002). The corresponding values of total Rrs were 10,09±3,90 and8,29±2,73 cm H2O×L-1×sec, respectively (p=0,08). These results indicate that Ers decreasessubstantially during anesthesia compared to anesthesia-paralysis in patients after coronary arterybypass graft surgery, whereas Rrs remains virtually unchanged. Changes in impedance due topliometric work done by the inspiratory muscles during relaxation were neglected.The first measurements of inspiratory muscle activity and related negative work duringspontaneous expiration in anesthetized patients after coronary artery bypass graft surgery is alsoprovided. Patients under investigation showed marked braking of expiratory flow by Pmusi.Themean time for Pmusi to decrease to 50 and 0 % amounted to 48,8± 27,0 msec and 1.968± 989msec, respectively. Average value for flow-resistive work amounted to 84,4±8,7 % of theelastic energy stored during inspiration.The remaining portion, used as negative inspiratorymuscle work, amounted to 15,6 ± 8,7 %."],"dc:identifier":["10.12681/eadd/27876","http://hdl.handle.net/10442/hedi/27876"],"dc:language":["gre"],"dc:publisher":["National and Kapodistrian University of Athens","Εθνικό και Καποδιστριακό Πανεπιστήμιο Αθηνών (ΕΚΠΑ)"],"dc:subject":["Μηχανική αναπνευστικού","Δραστηριότητα εισπνευστικών μυών κατά την εκπνοή","Ολική ελαστικότητα αναπνευστικού","Ολικές αντιστάσεις αναπνευστικού","Καμπύλες ροής-όγκου","Respiratory mechanics","Post-inspiratory muscle activity","Total respiratory elastance","Total respiratory resistance","Flow-volume curves","Ιατρική και Επιστήμες Υγείας","Κλινική Ιατρική","Medical and Health Sciences","Clinical Medicine"],"dc:title":["Η δραστηριότητα των εισπνευστικών μυών κατά την εκπνοή σε ασθενείς μετά από αορτοστεφανιαία παράκαμψη (bypass)","Post-inspiratory muscle activity in anesthetized patients after coronary artery bypass graft surgery (CABG)"],"dc:type":["PhD Thesis"]},"updated_at":"2026-11-18T20:48:35Z"}