{"id":{"repo_id":"greece","oai_identifier":"oai:10442/35819"},"canonical_url":"https://search.ndltd.org/etd/greece/oai:10442/35819","repository":{"repo_id":"greece","name":"Greek National Archive of PhD Theses","base_url":"https://phdtheses.ekt.gr/eadd_oai/request"},"display":{"title":"The anterior component of occlusal force and lower tooth movements: theoretical considerations and direct measurements","abstract":"Objective: To evaluate the relation between the anterior component of occlusal force (ACF) and mesial movement of lower teeth.Methods: The sample comprised 30 subjects (age: 21.5, SD: 2.7). ACF was computed as the difference in contact point tightness (CPT) between the biting and non-biting conditions. The sensor used for bite force measurements was 4 mm in thickness, and the interproximal sensor was 0.2 mm thick, inserted between the lower first molar and second premolar. Tooth movements were computed in three axes in space using superimposition of digital casts of the subjects 4 hours subsequent to insertion of a separator mesial to the lower first molar without occlusal loads and just after occlusal loads for another 4 hours.Results: The average ACF for the whole sample was 20.59 N (SD: 4.60). A significant reduction in tooth movement was observed between the chewing and non-chewing conditions for both teeth. Additionally, no relations were found between the mesio-distal movement and ACF (R2=0.033, 0.028) for premolars and molars respectively.Conclusions: No correlation was found between mesial tooth movements and ACF in function. Subsequent to mastication, teeth moved in lingual and inferior directions, and also closer together to contain the occlusal load.","abstract_html":"Objective: To evaluate the relation between the anterior component of occlusal force (ACF) and mesial movement of lower teeth.Methods: The sample comprised 30 subjects (age: 21.5, SD: 2.7). ACF was computed as the difference in contact point tightness (CPT) between the biting and non-biting conditions. The sensor used for bite force measurements was 4 mm in thickness, and the interproximal sensor was 0.2 mm thick, inserted between the lower first molar and second premolar. Tooth movements were computed in three axes in space using superimposition of digital casts of the subjects 4 hours subsequent to insertion of a separator mesial to the lower first molar without occlusal loads and just after occlusal loads for another 4 hours.Results: The average ACF for the whole sample was 20.59 N (SD: 4.60). A significant reduction in tooth movement was observed between the chewing and non-chewing conditions for both teeth. Additionally, no relations were found between the mesio-distal movement and ACF (R2=0.033, 0.028) for premolars and molars respectively.Conclusions: No correlation was found between mesial tooth movements and ACF in function. Subsequent to mastication, teeth moved in lingual and inferior directions, and also closer together to contain the occlusal load.","abstract_has_math":false,"creators":["Salih, Sarmad","Σαλέχ, Σαρμάντ"],"institution":"National and Kapodistrian University of Athens","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015","date_published":"2015","updated_at":"2026-11-18T21:23:57Z","subjects":["Μασητική δύναμη","Occlusal force","Ιατρική και Επιστήμες Υγείας","Επιστήμες Υγείας","Medical and Health Sciences","Health Sciences"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["10.12681/eadd/35819"],"render_values":[{"text":"10.12681/eadd/35819","href":"https://doi.org/10.12681/eadd/35819","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10442/hedi/35819","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/10442/hedi/35819","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://phdtheses.ekt.gr/eadd_oai/request?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3A10442%2F35819","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Salih, Sarmad","Σαλέχ, Σαρμάντ"]},{"key":"dc:creator.fathername","label":"Dc Creator Fathername","values":["Sobhi"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015"]},{"key":"dc:publisher","label":"Institution","values":["National and Kapodistrian University of Athens","Εθνικό και Καποδιστριακό Πανεπιστήμιο Αθηνών (ΕΚΠΑ)"]},{"key":"dc:type","label":"Dc Type","values":["PhD Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Μασητική δύναμη","Occlusal force","Ιατρική και Επιστήμες Υγείας","Επιστήμες Υγείας","Medical and Health Sciences","Health Sciences"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.12681/eadd/35819","http://hdl.handle.net/10442/hedi/35819"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Objective: To evaluate the relation between the anterior component of occlusal force (ACF) and mesial movement of lower teeth.Methods: The sample comprised 30 subjects (age: 21.5, SD: 2.7). ACF was computed as the difference in contact point tightness (CPT) between the biting and non-biting conditions. The sensor used for bite force measurements was 4 mm in thickness, and the interproximal sensor was 0.2 mm thick, inserted between the lower first molar and second premolar. Tooth movements were computed in three axes in space using superimposition of digital casts of the subjects 4 hours subsequent to insertion of a separator mesial to the lower first molar without occlusal loads and just after occlusal loads for another 4 hours.Results: The average ACF for the whole sample was 20.59 N (SD: 4.60). A significant reduction in tooth movement was observed between the chewing and non-chewing conditions for both teeth. Additionally, no relations were found between the mesio-distal movement and ACF (R2=0.033, 0.028) for premolars and molars respectively.Conclusions: No correlation was found between mesial tooth movements and ACF in function. Subsequent to mastication, teeth moved in lingual and inferior directions, and also closer together to contain the occlusal load.","Σκοπός: Η αξιολόγηση της σχέσης της πρόσθιας συνιστώσας της μασητικής δύναμης (ΠΣΜΔ) με την εγγύς μετακίνηση των κάτω δοντιών.Μέθοδος: Το δείγμα αποτελείτο από 30 άτομα (μέση ηλικία: 21.5, τυπική απόκλιση: 2.7). Η ΠΣΜΔ υπολογίστηκε ως η αύξηση της δύναμης στο σημείο επαφής μεταξύ του κάτω πρώτου γομφίου και δευτέρου προγομφίου, κατά τη δήξη. Ο αισθητήρας μέτρησης της μασητικής δύναμης ήταν 4 χιλ. σε πάχος, ενώ ο αισθητήρας της μεσοδόντιας δύναμης ήταν 0.2 χιλ. Οι μετακινήσεις των δοντιών μετρήθηκαν στους 3 άξονες του χώρου με αλληλεπίθεση ψηφιακών εκμαγείων, τα οποία ελήφθησαν 4 ώρες μετά την τοποθέτηση διαχωριστικού ελαστικού δακτυλίου μεταξύ κάτω πρώτου γομφίου και δευτέρου προγομφίου. Έγιναν δύο ομάδες μετρήσεων, μία χωρίς και μία με εφαρμογή μασητικών δυνάμεων κατά την περίοδο των 4 ωρών.Αποτελέσματα: Η μέση τιμή της ΠΣΜΔ ήταν 20.59 N (τυπική απόκλιση: 4.60). Σημαντική μείωση της οδοντικής μετακίνησης παρατηρήθηκε με την εφαρμογή μασητικών δυνάμεων. Δεν παρατηρήθηκε συσχέτιση μεταξύ της εγγύς-άπω μετακίνησης του γομφίου και προγομφίου και του μεγέθους της ΠΣΜΔ (R2=0.033, 0.028).Συμπεράσματα: Δεν βρέθηκε συσχέτιση μεταξύ της εγγύς μετακίνησης των δοντιών και της ΠΣΜΔ. Μετά από συνεχή μάσηση, τα δόντια μετακινήθηκαν περισσότερο γλωσσικά και αυχενικά, καθώς και συμπλησίασαν, σε σχέση με την εφαρμογή διαχωριστικού χωρίς μάσηση."]},{"key":"dc:title","label":"Title","values":["The anterior component of occlusal force and lower tooth movements: theoretical considerations and direct measurements","Η επίδραση της πρόσθιας συνιστώσας της μασητικής δύναμης στην μετακίνηση των κάτω δοντιών"]}]}],"canonical_facts":{"dc:creator":["Salih, Sarmad","Σαλέχ, Σαρμάντ"],"dc:creator.fathername":["Sobhi"],"dc:date":["2015"],"dc:description":["Objective: To evaluate the relation between the anterior component of occlusal force (ACF) and mesial movement of lower teeth.Methods: The sample comprised 30 subjects (age: 21.5, SD: 2.7). ACF was computed as the difference in contact point tightness (CPT) between the biting and non-biting conditions. The sensor used for bite force measurements was 4 mm in thickness, and the interproximal sensor was 0.2 mm thick, inserted between the lower first molar and second premolar. Tooth movements were computed in three axes in space using superimposition of digital casts of the subjects 4 hours subsequent to insertion of a separator mesial to the lower first molar without occlusal loads and just after occlusal loads for another 4 hours.Results: The average ACF for the whole sample was 20.59 N (SD: 4.60). A significant reduction in tooth movement was observed between the chewing and non-chewing conditions for both teeth. Additionally, no relations were found between the mesio-distal movement and ACF (R2=0.033, 0.028) for premolars and molars respectively.Conclusions: No correlation was found between mesial tooth movements and ACF in function. Subsequent to mastication, teeth moved in lingual and inferior directions, and also closer together to contain the occlusal load.","Σκοπός: Η αξιολόγηση της σχέσης της πρόσθιας συνιστώσας της μασητικής δύναμης (ΠΣΜΔ) με την εγγύς μετακίνηση των κάτω δοντιών.Μέθοδος: Το δείγμα αποτελείτο από 30 άτομα (μέση ηλικία: 21.5, τυπική απόκλιση: 2.7). Η ΠΣΜΔ υπολογίστηκε ως η αύξηση της δύναμης στο σημείο επαφής μεταξύ του κάτω πρώτου γομφίου και δευτέρου προγομφίου, κατά τη δήξη. Ο αισθητήρας μέτρησης της μασητικής δύναμης ήταν 4 χιλ. σε πάχος, ενώ ο αισθητήρας της μεσοδόντιας δύναμης ήταν 0.2 χιλ. Οι μετακινήσεις των δοντιών μετρήθηκαν στους 3 άξονες του χώρου με αλληλεπίθεση ψηφιακών εκμαγείων, τα οποία ελήφθησαν 4 ώρες μετά την τοποθέτηση διαχωριστικού ελαστικού δακτυλίου μεταξύ κάτω πρώτου γομφίου και δευτέρου προγομφίου. Έγιναν δύο ομάδες μετρήσεων, μία χωρίς και μία με εφαρμογή μασητικών δυνάμεων κατά την περίοδο των 4 ωρών.Αποτελέσματα: Η μέση τιμή της ΠΣΜΔ ήταν 20.59 N (τυπική απόκλιση: 4.60). Σημαντική μείωση της οδοντικής μετακίνησης παρατηρήθηκε με την εφαρμογή μασητικών δυνάμεων. Δεν παρατηρήθηκε συσχέτιση μεταξύ της εγγύς-άπω μετακίνησης του γομφίου και προγομφίου και του μεγέθους της ΠΣΜΔ (R2=0.033, 0.028).Συμπεράσματα: Δεν βρέθηκε συσχέτιση μεταξύ της εγγύς μετακίνησης των δοντιών και της ΠΣΜΔ. Μετά από συνεχή μάσηση, τα δόντια μετακινήθηκαν περισσότερο γλωσσικά και αυχενικά, καθώς και συμπλησίασαν, σε σχέση με την εφαρμογή διαχωριστικού χωρίς μάσηση."],"dc:identifier":["10.12681/eadd/35819","http://hdl.handle.net/10442/hedi/35819"],"dc:language":["eng"],"dc:publisher":["National and Kapodistrian University of Athens","Εθνικό και Καποδιστριακό Πανεπιστήμιο Αθηνών (ΕΚΠΑ)"],"dc:subject":["Μασητική δύναμη","Occlusal force","Ιατρική και Επιστήμες Υγείας","Επιστήμες Υγείας","Medical and Health Sciences","Health Sciences"],"dc:title":["The anterior component of occlusal force and lower tooth movements: theoretical considerations and direct measurements","Η επίδραση της πρόσθιας συνιστώσας της μασητικής δύναμης στην μετακίνηση των κάτω δοντιών"],"dc:type":["PhD Thesis"]},"updated_at":"2026-11-18T21:23:57Z"}