{"id":{"repo_id":"greece","oai_identifier":"oai:10442/37154"},"canonical_url":"https://search.ndltd.org/etd/greece/oai:10442/37154","repository":{"repo_id":"greece","name":"Greek National Archive of PhD Theses","base_url":"https://phdtheses.ekt.gr/eadd_oai/request"},"display":{"title":"Διακαθετηριακή εμφύτευση τεχνητής αυτοεκπτυσσόμενης βιοπροσθετικής αορτικής βαλβίδας για την αντιμετώπιση συμπτωματικής σοβαρής αορτικής στένωσης: επίδραση στις μηχανικές ιδιότητες της αορτής","abstract":"Introduction: Mechanical aortic properties have been shown to transiently deteriorate in the early post-operative after surgical interventions in the aortic valve (or root) replacement. Aortic stiffness is an independent predictor of cardiovascular risk and mortality. Aim: To evaluate the effect of Transcatheter Aortic Valve Implantation (TAVI) on ascending aorta's elasticity. Methods: Aortic stiffness indices were measured non-invasively (echocardiographically) at baseline, 7 days and 1 month post TAVI and invasively (angiographically) acutely pre- and post- TAVI. Invasive evaluation was conducted for two levels of the ascending aorta (3 cm and 6 cm above aortic valve). Results: A total of 30 patients (47% males) were studied with a mean age of 79.9 ± 4.7 years. No significant changes in aortic stiffness indices (aortic distensibility, aortic compliance, aortic stiffness index) were observed. In particular, aortic distensibility remained unchanged post-TAVI as evaluated both non-invasively (from 1.89 ± 1.11 at baseline, to 2.05 ± 1.50 at 7 days post-TAVI, to 1.84 ± 1.34 cm2/(dynes*106); p=0.497) and invasively (at the 3 cm above aortic valve level: from 0.88 ± 0.44 pre- to 0.82 ± 0.47 cm2/(dynes*106) post- TAVI, p=0.637. Results were similar at the 6 cm above aortic valve level. Conclusion: TAVI has no effect on mechanical properties of the ascending aorta in the early post-operative period (up to 1 month).","abstract_html":"Introduction: Mechanical aortic properties have been shown to transiently deteriorate in the early post-operative after surgical interventions in the aortic valve (or root) replacement. Aortic stiffness is an independent predictor of cardiovascular risk and mortality. Aim: To evaluate the effect of Transcatheter Aortic Valve Implantation (TAVI) on ascending aorta&#x27;s elasticity. Methods: Aortic stiffness indices were measured non-invasively (echocardiographically) at baseline, 7 days and 1 month post TAVI and invasively (angiographically) acutely pre- and post- TAVI. Invasive evaluation was conducted for two levels of the ascending aorta (3 cm and 6 cm above aortic valve). Results: A total of 30 patients (47% males) were studied with a mean age of 79.9 ± 4.7 years. No significant changes in aortic stiffness indices (aortic distensibility, aortic compliance, aortic stiffness index) were observed. In particular, aortic distensibility remained unchanged post-TAVI as evaluated both non-invasively (from 1.89 ± 1.11 at baseline, to 2.05 ± 1.50 at 7 days post-TAVI, to 1.84 ± 1.34 cm2/(dynes*106); p=0.497) and invasively (at the 3 cm above aortic valve level: from 0.88 ± 0.44 pre- to 0.82 ± 0.47 cm2/(dynes*106) post- TAVI, p=0.637. Results were similar at the 6 cm above aortic valve level. Conclusion: TAVI has no effect on mechanical properties of the ascending aorta in the early post-operative period (up to 1 month).","abstract_has_math":false,"creators":["Vrachatis, Dimitrios","Βραχάτης, Δημήτριος"],"institution":"National and Kapodistrian University of Athens","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014","date_published":"2014","updated_at":"2026-11-18T21:25:01Z","subjects":["Αορτική στένωση","Διακαθετηριακή εμφύτευση αορτικής βαλβίδας","Βιοπρόσθεση CoreValve","Αορτική διατασιμότητα","Αορτική ελαστικότητα","Aortic stenosis","Transcatheter aortic valve implantation","CoreValve bioprosthesis","Aortic distensibility","Aortic elasticity","Ιατρική και Επιστήμες Υγείας","Κλινική Ιατρική","Ιατρική Βιοτεχνολογία","Medical and Health Sciences","Clinical Medicine","Medical Biotechnology"],"languages":["gre"],"rights":["BY_NC"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["10.12681/eadd/37154"],"render_values":[{"text":"10.12681/eadd/37154","href":"https://doi.org/10.12681/eadd/37154","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10442/hedi/37154","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/10442/hedi/37154","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://phdtheses.ekt.gr/eadd_oai/request?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3A10442%2F37154","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Vrachatis, Dimitrios","Βραχάτης, Δημήτριος"]},{"key":"dc:creator.fathername","label":"Dc Creator Fathername","values":["Antonios"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2014"]},{"key":"dc:publisher","label":"Institution","values":["National and Kapodistrian University of Athens","Εθνικό και Καποδιστριακό Πανεπιστήμιο Αθηνών (ΕΚΠΑ)"]},{"key":"dc:type","label":"Dc Type","values":["PhD Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Αορτική στένωση","Διακαθετηριακή εμφύτευση αορτικής βαλβίδας","Βιοπρόσθεση CoreValve","Αορτική διατασιμότητα","Αορτική ελαστικότητα","Aortic stenosis","Transcatheter aortic valve implantation","CoreValve bioprosthesis","Aortic distensibility","Aortic elasticity","Ιατρική και Επιστήμες Υγείας","Κλινική Ιατρική","Ιατρική Βιοτεχνολογία","Medical and Health Sciences","Clinical Medicine","Medical Biotechnology"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["gre"]},{"key":"dc:rights","label":"Dc Rights","values":["BY_NC"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.12681/eadd/37154","http://hdl.handle.net/10442/hedi/37154"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Introduction: Mechanical aortic properties have been shown to transiently deteriorate in the early post-operative after surgical interventions in the aortic valve (or root) replacement. Aortic stiffness is an independent predictor of cardiovascular risk and mortality. Aim: To evaluate the effect of Transcatheter Aortic Valve Implantation (TAVI) on ascending aorta's elasticity. Methods: Aortic stiffness indices were measured non-invasively (echocardiographically) at baseline, 7 days and 1 month post TAVI and invasively (angiographically) acutely pre- and post- TAVI. Invasive evaluation was conducted for two levels of the ascending aorta (3 cm and 6 cm above aortic valve). Results: A total of 30 patients (47% males) were studied with a mean age of 79.9 ± 4.7 years. No significant changes in aortic stiffness indices (aortic distensibility, aortic compliance, aortic stiffness index) were observed. In particular, aortic distensibility remained unchanged post-TAVI as evaluated both non-invasively (from 1.89 ± 1.11 at baseline, to 2.05 ± 1.50 at 7 days post-TAVI, to 1.84 ± 1.34 cm2/(dynes*106); p=0.497) and invasively (at the 3 cm above aortic valve level: from 0.88 ± 0.44 pre- to 0.82 ± 0.47 cm2/(dynes*106) post- TAVI, p=0.637. Results were similar at the 6 cm above aortic valve level. Conclusion: TAVI has no effect on mechanical properties of the ascending aorta in the early post-operative period (up to 1 month).","Εισαγωγή: Προηγούμενες μελέτες έχουν δείξει μία παροδική επιδείνωση των μηχανικών ιδιοτήτων της αορτής μετά από χειρουργική αντικατάσταση αορτικής βαλβίδας (ή ρίζας) (ΑΒ). Η αορτική ελαστικότητα αποτελεί ανεξάρτητο προγνωστικό παράγοντα καρδιαγγειακού κινδύνου και θνησιμότητας. Στόχος: Να διερευνηθεί η επίδραση της διακαθετηριακής εμφύτευσης ΑΒ στην ελαστικότητα της αορτής. Μέθοδος: Η αορτική ελαστικότητα εκτιμήθηκε μη επεμβατικά (υπερηχογραφικά) πριν, 7 ημέρες και 1 μήνα μετεπεμβατικά. Οι αορτικές ελαστικές ιδιότητες μελετήθηκαν, επίσης, με επεμβατικό τρόπο (αγγειογραφικά) σε δύο επίπεδα (3 και 6 cm ύπερθεν της ΑΒ) αμέσως πριν και αμέσως μετά την επέμβαση. Αποτελέσματα: Μελετήθηκαν 30 ασθενείς (47% άνδρες) μέσης ηλικίας 79,9 ± 4,7 ετών. Δεν παρατηρήθηκαν σημαντικές μεταβολές των δεικτών ελαστικότητας που υπολογίστηκαν μετά την επέμβαση (αορτική διατασιμότητα, αορτική ενδοτικότητα, δείκτης αορτικής σκληρίας). Συγκεκριμένα, η αορτική διατασιμότητα παρέμεινε αμετάβλητη τόσο κατά την υπερηχογραφική αξιολόγηση: από 1,89 ± 1,11 (αρχικά), σε 2,05 ± 1,50 (7 ημέρες μετά) και 1,84 ± 1,34 cm2/(dynes*106) (1 μήνα μετά) - p=0,497, όσο και κατά την αγγειογραφική αξιολόγηση. Ειδικότερα, στο επίπεδο των 3 cm ύπερθεν της ΑΒ, η αορτική διατασιμότητα παρέμεινε αμετάβλητη από 0,88 ± 0,44 (αμέσως πριν) σε 0,82 ± 0,47 cm2/(dynes*106) (αμέσως μετά την επέμβαση), p=0,637. Αντίστοιχα ήταν τα αποτελέσματα για το επίπεδο των 6 cm ύπερθεν της ΑΒ. Συμπέρασμα: Η διακαθετηριακή εμφύτευση ΑΒ δεν επιδρά στις μηχανικές ιδιότητες της ανιούσας αορτής κατά την βραχυπρόθεσμη μετεπεμβατική περίοδο (1 μήνας)."]},{"key":"dc:title","label":"Title","values":["Διακαθετηριακή εμφύτευση τεχνητής αυτοεκπτυσσόμενης βιοπροσθετικής αορτικής βαλβίδας για την αντιμετώπιση συμπτωματικής σοβαρής αορτικής στένωσης: επίδραση στις μηχανικές ιδιότητες της αορτής","Transcatheter implantation of a self-expanding bioprosthetic aortic valve for symptomatic severe aortic stenosis: the effect on aortic mechanical properties"]}]}],"canonical_facts":{"dc:creator":["Vrachatis, Dimitrios","Βραχάτης, Δημήτριος"],"dc:creator.fathername":["Antonios"],"dc:date":["2014"],"dc:description":["Introduction: Mechanical aortic properties have been shown to transiently deteriorate in the early post-operative after surgical interventions in the aortic valve (or root) replacement. Aortic stiffness is an independent predictor of cardiovascular risk and mortality. Aim: To evaluate the effect of Transcatheter Aortic Valve Implantation (TAVI) on ascending aorta's elasticity. Methods: Aortic stiffness indices were measured non-invasively (echocardiographically) at baseline, 7 days and 1 month post TAVI and invasively (angiographically) acutely pre- and post- TAVI. Invasive evaluation was conducted for two levels of the ascending aorta (3 cm and 6 cm above aortic valve). Results: A total of 30 patients (47% males) were studied with a mean age of 79.9 ± 4.7 years. No significant changes in aortic stiffness indices (aortic distensibility, aortic compliance, aortic stiffness index) were observed. In particular, aortic distensibility remained unchanged post-TAVI as evaluated both non-invasively (from 1.89 ± 1.11 at baseline, to 2.05 ± 1.50 at 7 days post-TAVI, to 1.84 ± 1.34 cm2/(dynes*106); p=0.497) and invasively (at the 3 cm above aortic valve level: from 0.88 ± 0.44 pre- to 0.82 ± 0.47 cm2/(dynes*106) post- TAVI, p=0.637. Results were similar at the 6 cm above aortic valve level. Conclusion: TAVI has no effect on mechanical properties of the ascending aorta in the early post-operative period (up to 1 month).","Εισαγωγή: Προηγούμενες μελέτες έχουν δείξει μία παροδική επιδείνωση των μηχανικών ιδιοτήτων της αορτής μετά από χειρουργική αντικατάσταση αορτικής βαλβίδας (ή ρίζας) (ΑΒ). Η αορτική ελαστικότητα αποτελεί ανεξάρτητο προγνωστικό παράγοντα καρδιαγγειακού κινδύνου και θνησιμότητας. Στόχος: Να διερευνηθεί η επίδραση της διακαθετηριακής εμφύτευσης ΑΒ στην ελαστικότητα της αορτής. Μέθοδος: Η αορτική ελαστικότητα εκτιμήθηκε μη επεμβατικά (υπερηχογραφικά) πριν, 7 ημέρες και 1 μήνα μετεπεμβατικά. Οι αορτικές ελαστικές ιδιότητες μελετήθηκαν, επίσης, με επεμβατικό τρόπο (αγγειογραφικά) σε δύο επίπεδα (3 και 6 cm ύπερθεν της ΑΒ) αμέσως πριν και αμέσως μετά την επέμβαση. Αποτελέσματα: Μελετήθηκαν 30 ασθενείς (47% άνδρες) μέσης ηλικίας 79,9 ± 4,7 ετών. Δεν παρατηρήθηκαν σημαντικές μεταβολές των δεικτών ελαστικότητας που υπολογίστηκαν μετά την επέμβαση (αορτική διατασιμότητα, αορτική ενδοτικότητα, δείκτης αορτικής σκληρίας). Συγκεκριμένα, η αορτική διατασιμότητα παρέμεινε αμετάβλητη τόσο κατά την υπερηχογραφική αξιολόγηση: από 1,89 ± 1,11 (αρχικά), σε 2,05 ± 1,50 (7 ημέρες μετά) και 1,84 ± 1,34 cm2/(dynes*106) (1 μήνα μετά) - p=0,497, όσο και κατά την αγγειογραφική αξιολόγηση. Ειδικότερα, στο επίπεδο των 3 cm ύπερθεν της ΑΒ, η αορτική διατασιμότητα παρέμεινε αμετάβλητη από 0,88 ± 0,44 (αμέσως πριν) σε 0,82 ± 0,47 cm2/(dynes*106) (αμέσως μετά την επέμβαση), p=0,637. Αντίστοιχα ήταν τα αποτελέσματα για το επίπεδο των 6 cm ύπερθεν της ΑΒ. Συμπέρασμα: Η διακαθετηριακή εμφύτευση ΑΒ δεν επιδρά στις μηχανικές ιδιότητες της ανιούσας αορτής κατά την βραχυπρόθεσμη μετεπεμβατική περίοδο (1 μήνας)."],"dc:identifier":["10.12681/eadd/37154","http://hdl.handle.net/10442/hedi/37154"],"dc:language":["gre"],"dc:publisher":["National and Kapodistrian University of Athens","Εθνικό και Καποδιστριακό Πανεπιστήμιο Αθηνών (ΕΚΠΑ)"],"dc:rights":["BY_NC"],"dc:subject":["Αορτική στένωση","Διακαθετηριακή εμφύτευση αορτικής βαλβίδας","Βιοπρόσθεση CoreValve","Αορτική διατασιμότητα","Αορτική ελαστικότητα","Aortic stenosis","Transcatheter aortic valve implantation","CoreValve bioprosthesis","Aortic distensibility","Aortic elasticity","Ιατρική και Επιστήμες Υγείας","Κλινική Ιατρική","Ιατρική Βιοτεχνολογία","Medical and Health Sciences","Clinical Medicine","Medical Biotechnology"],"dc:title":["Διακαθετηριακή εμφύτευση τεχνητής αυτοεκπτυσσόμενης βιοπροσθετικής αορτικής βαλβίδας για την αντιμετώπιση συμπτωματικής σοβαρής αορτικής στένωσης: επίδραση στις μηχανικές ιδιότητες της αορτής","Transcatheter implantation of a self-expanding bioprosthetic aortic valve for symptomatic severe aortic stenosis: the effect on aortic mechanical properties"],"dc:type":["PhD Thesis"]},"updated_at":"2026-11-18T21:25:01Z"}