{"id":{"repo_id":"greece","oai_identifier":"oai:10442/3762"},"canonical_url":"https://search.ndltd.org/etd/greece/oai:10442/3762","repository":{"repo_id":"greece","name":"Greek National Archive of PhD Theses","base_url":"https://phdtheses.ekt.gr/eadd_oai/request"},"display":{"title":"ΒΕΛΤΙΣΤΗ ΣΥΝΕΡΓΑΣΙΑ ΥΔΡΟΗΛΕΚΤΡΙΚΩΝ ΚΑΙ ΘΕΡΜΙΚΩΝ ΣΤΑΘΜΩΝ ΠΑΡΑΓΩΓΗΣ ΗΛΕΚΤΡΙΚΗΣ ΕΝΕΡΓΕΙΑΣ","abstract":"THE OBJECT OF THIS DOCTORALK THESIS IS THE CREATION OF AN INTEGRATED SYSTEM (NAMED \"NEREUS\") WHICH SOLVES THE PROBLEM OF LONG-TERM PLANNING OF HYDROTHERMAL COOPERATION, THAT IS THE ECONOMIC RUNNING OF A MIXED HYDROTHERMAL POWER PRODUCTION SYSTEM, WITHIN THE TIME HORIZON OF ONE YEAR. THIS VERY SYSTEM: - DEVELOPS AMODEL AND A NUMBER OF METHODS FOR SOLVING THE PROBLEM CONCERNING THE LONG-TERM PLANNING OF HYDROTHERMAL COOPERATION IN THE CASES OF REAL PRODUCTION SYSTEMS WITH SEVERAL AND VARIOUS THERMOELECTRIC AND HYDROELECTRIC PLANTS (IT COPES WITH THE ACCURATE FUEL COST FUNCTIONS OF HYDROTHERMAL PLANTS, THE CHANGING HEIGHT OF FALL IN THE HYDROELECTRIC ONES, THE CORRELATION OF THE SUCCESSIVE INFLOWS, THE TECHNICAL AND FUNCTIONAL CONSTRAINTS OF THE SYSTEM). - DETERMINES BYMEANS OF AN ORIGINAL METHOD THE OPTIMUM PUMPING LOAD, THE CORRESPONDING HYDRAULIC PRODUCTION AND THE RESULTING PROFIT FOR EACH TIME-INTERVAL. - ESTIMATES THE FUEL COST FUNCTIONS, TAKING FOR GRANTED THE MAINTENANCE PLANNING AND THE F.O.R. OF THE PLANTS. - RESEARCHES INTO THE CORRELATION OF THE INFLOWS AND SUGGESTS THE ADVISABLE TIME-INTERVALS WHICH THE ANNUAL TIME-HORIZON OF THE PROBLEM IS DIVIDED IN. - OPTIMIZES THE HYDROELECTRIC ENERGY PRODUCTION IN EACH TIME-INTERVAL AND FOR EACH HYDROELECTRIC PLANT OF THE PRODUCTION SYSTEM. - PROVIDES THE BASIC ELEMENTS FOR THE ANNUAL ENERGY BUDGET AS WELL AS FOR THE PLANNINGOF INVESTMENTS ANF OF THE EXPANSION OF THE POWER SYSTEM. - OFFERS THE POSSIBILITY FOR A REASSESSMENT AND A MODIFICATION OF THE DECISIONS THAT HAVE BEEN MADE. (ABSTRACT TRUNCATED)","abstract_html":"THE OBJECT OF THIS DOCTORALK THESIS IS THE CREATION OF AN INTEGRATED SYSTEM (NAMED &quot;NEREUS&quot;) WHICH SOLVES THE PROBLEM OF LONG-TERM PLANNING OF HYDROTHERMAL COOPERATION, THAT IS THE ECONOMIC RUNNING OF A MIXED HYDROTHERMAL POWER PRODUCTION SYSTEM, WITHIN THE TIME HORIZON OF ONE YEAR. THIS VERY SYSTEM: - DEVELOPS AMODEL AND A NUMBER OF METHODS FOR SOLVING THE PROBLEM CONCERNING THE LONG-TERM PLANNING OF HYDROTHERMAL COOPERATION IN THE CASES OF REAL PRODUCTION SYSTEMS WITH SEVERAL AND VARIOUS THERMOELECTRIC AND HYDROELECTRIC PLANTS (IT COPES WITH THE ACCURATE FUEL COST FUNCTIONS OF HYDROTHERMAL PLANTS, THE CHANGING HEIGHT OF FALL IN THE HYDROELECTRIC ONES, THE CORRELATION OF THE SUCCESSIVE INFLOWS, THE TECHNICAL AND FUNCTIONAL CONSTRAINTS OF THE SYSTEM). - DETERMINES BYMEANS OF AN ORIGINAL METHOD THE OPTIMUM PUMPING LOAD, THE CORRESPONDING HYDRAULIC PRODUCTION AND THE RESULTING PROFIT FOR EACH TIME-INTERVAL. - ESTIMATES THE FUEL COST FUNCTIONS, TAKING FOR GRANTED THE MAINTENANCE PLANNING AND THE F.O.R. OF THE PLANTS. - RESEARCHES INTO THE CORRELATION OF THE INFLOWS AND SUGGESTS THE ADVISABLE TIME-INTERVALS WHICH THE ANNUAL TIME-HORIZON OF THE PROBLEM IS DIVIDED IN. - OPTIMIZES THE HYDROELECTRIC ENERGY PRODUCTION IN EACH TIME-INTERVAL AND FOR EACH HYDROELECTRIC PLANT OF THE PRODUCTION SYSTEM. - PROVIDES THE BASIC ELEMENTS FOR THE ANNUAL ENERGY BUDGET AS WELL AS FOR THE PLANNINGOF INVESTMENTS ANF OF THE EXPANSION OF THE POWER SYSTEM. - OFFERS THE POSSIBILITY FOR A REASSESSMENT AND A MODIFICATION OF THE DECISIONS THAT HAVE BEEN MADE. (ABSTRACT TRUNCATED)","abstract_has_math":false,"creators":["Καβράκος, Μιλτιάδης"],"institution":"National Technical University of Athens (NTUA)","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1994,"date_issued":"1994","date_published":"1994","updated_at":"2026-11-18T20:22:22Z","subjects":["ΒΕΛΤΙΣΤΗ ΠΑΡΑΓΩΓΗ ΥΔΡΟΗΛΕΚΤΡΙΚΗΣ ΕΝΕΡΓΕΙΑΣ","ΒΕΛΤΙΣΤΟ ΑΝΤΛΗΤΙΚΟ ΦΟΡΤΙΟ","Διαχείριση νερού","ΔΥΝΑΜΙΚΟΣ/ΜΗ ΓΡΑΜΜΙΚΟΣ ΠΡΟΓΡΑΜΜΑΤΙΣΜΟΣ","Στοχαστικότητα","Υδροθερμική συνεργασία","HYDROTHERMAL COOPERATION","NON LINEAR PROGRAMMING - DYNAMICPROGRAMMING","Optimum hydroelectric energy production","OPTIMUM PUMPING LOAD","Stochastic","WATER ALLOCATION","Επιστήμες Μηχανικού και Τεχνολογία","Επιστήμη Μηχανολόγου Μηχανικού","Engineering and Technology","Mechanical Engineering"],"languages":["gre"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["10.12681/eadd/3762"],"render_values":[{"text":"10.12681/eadd/3762","href":"https://doi.org/10.12681/eadd/3762","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10442/hedi/3762","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/10442/hedi/3762","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://phdtheses.ekt.gr/eadd_oai/request?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3A10442%2F3762","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Καβράκος, Μιλτιάδης"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1994"]},{"key":"dc:publisher","label":"Institution","values":["National Technical University of Athens (NTUA)","Εθνικό Μετσόβιο Πολυτεχνείο (ΕΜΠ)"]},{"key":"dc:type","label":"Dc Type","values":["PhD Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["ΒΕΛΤΙΣΤΗ ΠΑΡΑΓΩΓΗ ΥΔΡΟΗΛΕΚΤΡΙΚΗΣ ΕΝΕΡΓΕΙΑΣ","ΒΕΛΤΙΣΤΟ ΑΝΤΛΗΤΙΚΟ ΦΟΡΤΙΟ","Διαχείριση νερού","ΔΥΝΑΜΙΚΟΣ/ΜΗ ΓΡΑΜΜΙΚΟΣ ΠΡΟΓΡΑΜΜΑΤΙΣΜΟΣ","Στοχαστικότητα","Υδροθερμική συνεργασία","HYDROTHERMAL COOPERATION","NON LINEAR PROGRAMMING - DYNAMICPROGRAMMING","Optimum hydroelectric energy production","OPTIMUM PUMPING LOAD","Stochastic","WATER ALLOCATION","Επιστήμες Μηχανικού και Τεχνολογία","Επιστήμη Μηχανολόγου Μηχανικού","Engineering and Technology","Mechanical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["gre"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.12681/eadd/3762","http://hdl.handle.net/10442/hedi/3762"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["THE OBJECT OF THIS DOCTORALK THESIS IS THE CREATION OF AN INTEGRATED SYSTEM (NAMED \"NEREUS\") WHICH SOLVES THE PROBLEM OF LONG-TERM PLANNING OF HYDROTHERMAL COOPERATION, THAT IS THE ECONOMIC RUNNING OF A MIXED HYDROTHERMAL POWER PRODUCTION SYSTEM, WITHIN THE TIME HORIZON OF ONE YEAR. THIS VERY SYSTEM: - DEVELOPS AMODEL AND A NUMBER OF METHODS FOR SOLVING THE PROBLEM CONCERNING THE LONG-TERM PLANNING OF HYDROTHERMAL COOPERATION IN THE CASES OF REAL PRODUCTION SYSTEMS WITH SEVERAL AND VARIOUS THERMOELECTRIC AND HYDROELECTRIC PLANTS (IT COPES WITH THE ACCURATE FUEL COST FUNCTIONS OF HYDROTHERMAL PLANTS, THE CHANGING HEIGHT OF FALL IN THE HYDROELECTRIC ONES, THE CORRELATION OF THE SUCCESSIVE INFLOWS, THE TECHNICAL AND FUNCTIONAL CONSTRAINTS OF THE SYSTEM). - DETERMINES BYMEANS OF AN ORIGINAL METHOD THE OPTIMUM PUMPING LOAD, THE CORRESPONDING HYDRAULIC PRODUCTION AND THE RESULTING PROFIT FOR EACH TIME-INTERVAL. - ESTIMATES THE FUEL COST FUNCTIONS, TAKING FOR GRANTED THE MAINTENANCE PLANNING AND THE F.O.R. OF THE PLANTS. - RESEARCHES INTO THE CORRELATION OF THE INFLOWS AND SUGGESTS THE ADVISABLE TIME-INTERVALS WHICH THE ANNUAL TIME-HORIZON OF THE PROBLEM IS DIVIDED IN. - OPTIMIZES THE HYDROELECTRIC ENERGY PRODUCTION IN EACH TIME-INTERVAL AND FOR EACH HYDROELECTRIC PLANT OF THE PRODUCTION SYSTEM. - PROVIDES THE BASIC ELEMENTS FOR THE ANNUAL ENERGY BUDGET AS WELL AS FOR THE PLANNINGOF INVESTMENTS ANF OF THE EXPANSION OF THE POWER SYSTEM. - OFFERS THE POSSIBILITY FOR A REASSESSMENT AND A MODIFICATION OF THE DECISIONS THAT HAVE BEEN MADE. (ABSTRACT TRUNCATED)","ΣΤΟΧΟ ΤΗΣ ΔΙΔΑΚΤΟΡΙΚΗΣ ΔΙΑΤΡΙΒΗΣ ΑΠΟΤΕΛΕΣΕ Η ΔΗΜΙΟΥΡΓΙΑ ΕΝΟΣ ΟΛΟΚΛΗΡΩΜΕΝΟΥ ΣΥΣΤΗΜΑΤΟΣ (ΤΟ ΟΝΟΜΑ ΑΥΤΟΥ \"ΝΗΡΕΥΣ\"), ΤΟ ΟΠΟΙΟ ΑΝΤΙΜΕΤΩΠΙΖΕΙ ΤΟ ΠΡΟΒΛΗΜΑ ΤΟΥ ΜΑΚΡΟΧΡΟΝΙΟΥ ΠΡΟΓΡΑΜΜΑΤΙΣΜΟΥ ΤΗΣ ΥΔΡΟΘΕΡΜΙΚΗΣ ΣΥΝΕΡΓΑΣΙΑΣ, ΤΗΣ ΟΙΚΟΝΟΜΙΚΗΣ ΔΗΛΑΔΗΛΕΙΤΟΥΡΓΙΑΣ ΕΝΟΣ ΜΙΚΤΟΥ ΥΔΡΟΘΕΡΜΙΚΟΥ ΣΥΣΤΗΜΑΤΟΣ ΠΑΡΑΓΩΓΗΣ ΗΛΕΚΤΡΙΚΗΣ ΕΝΕΡΓΕΙΑΣ ΣΕ ΧΡΟΝΙΚΟ ΟΡΙΖΟΝΤΑ ΕΝΟΣ ΕΤΟΥΣ. ΤΟ ΣΥΣΤΗΜΑ ΑΥΤΟ - ΛΑΜΒΑΝΕΙ ΥΠΟΨΗ ΤΑ ΠΡΑΓΜΑΤΙΚΑ ΧΑΡΑΚΤΗΡΙΣΤΙΚΑ ΤΩΝ ΣΥΣΤΗΜΑΤΩΝ ΠΑΡΑΓΩΓΗΣ (ΠΡΟΓΡΑΜΜΑΤΙΣΜΕΝΗ ΣΥΝΤΗΡΗΣΗ ΚΑΙ ΑΠΡΟΒΛΕΠΤΕΣ ΔΙΑΚΟΠΕΣ ΤΗΣ ΛΕΙΤΟΥΡΓΙΑΣ ΤΩΝ ΘΕΡΜΟΗΛΕΚΤΡΙΚΩΝ ΣΤΑΘΜΩΝ, ΑΚΡΙΒΕΙΣ ΧΑΡΑΚΤΗΡΙΣΤΙΚΕΣ ΚΟΣΤΟΥΣ ΚΑΥΣΙΜΟΥ, ΥΨΟΣ ΠΤΩΣΗΣ ΤΟΥ ΝΕΡΟΥ ΣΤΟΥΣ ΥΔΡΟΗΛΕΚΤΡΙΚΟΥΣ ΣΤΑΘΜΟΥΣ, ΣΥΣΧΕΤΙΣΗ ΔΙΑΔΟΧΙΚΩΝ ΕΙΣΡΟΩΝ, ΤΕΧΝΙΚΟΥΣ ΚΑΙ ΛΕΙΤΟΥΡΓΙΚΟΥΣ ΠΕΡΙΟΡΙΣΜΟΥΣ), - ΠΡΟΣΔΙΟΡΙΖΕΙ ΤΑ ΒΕΛΤΙΣΤΑ ΑΝΤΛΗΤΙΚΑ ΦΟΡΤΙΑ, ΤΗΝ ΑΝΤΙΣΤΟΙΧΗ ΥΔΡΑΥΛΙΚΗ ΠΑΡΑΓΩΓΗ ΚΑΙ ΤΗΝ ΩΦΕΛΕΙΑ ΠΟΥ ΠΡΟΚΥΠΤΕΙ ΓΙΑ ΚΑΘΕ ΥΠΟΔΙΑΣΤΗΜΑ ΤΟΥ ΕΤΟΥΣ, - ΒΡΙΣΚΕΙ ΤΙΣΣΥΝΑΡΤΗΣΕΙΣ ΤΩΝ ΧΑΡΑΚΤΗΡΙΣΤΙΚΩΝ ΚΟΣΤΟΥΣ ΚΑΥΣΙΜΟΥ ΜΕ ΔΕΔΟΜΕΝΟ ΤΟΝ ΠΡΟΓΡΑΜΜΑΤΙΣΜΟ ΣΥΝΤΗΡΗΣΗΣ ΚΑΙ ΤΑ F.O.R. ΤΩΝ ΜΟΝΑΔΩΝ, - ΕΡΕΥΝΑ ΤΗ ΣΥΣΧΕΤΙΣΗ ΤΩΝ ΕΙΣΡΟΩΝ ΚΑΙΥΠΟΛΟΓΙΖΕΙ ΤΙΣ ΠΙΘΑΝΟΤΗΤΕΣ ΜΕΤΑΒΑΣΕΩΣ ΑΠΟ ΕΝΑ ΠΛΗΘΟΣ ΤΙΜΩΝ ΣΕ ΕΝΑ ΑΛΛΟ, ΓΙΑ ΚΑΘΕ ΥΠΟΔΙΑΣΤΗΜΑ ΤΟΥ ΕΤΟΥΣ, - ΒΕΛΤΙΣΤΟΠΟΙΕΙ ΤΗ ΠΑΡΑΓΩΓΗ ΥΔΡΟΗΛΕΚΤΡΙΚΗΣ ΕΝΕΡΓΕΙΑΣ ΓΙΑ ΚΑΘΕ ΔΥΝΑΤΗ ΤΙΜΗ ΑΠΟΘΕΜΑΤΟΣ ΚΑΙ ΕΙΣΡΟΗΣ ΣΤΑ ΕΠΙΜΕΡΟΥΣ ΦΡΑΓΜΑΤΑ, - ΣΥΝΟΔΕΥΕΤΑΙ ΑΠΟ ΕΡΓΑΛΕΙΟ ΑΞΙΟΛΟΓΗΣΗΣ ΜΟΝΤΕΛΩΝ ΠΡΟΒΛΕΨΗΣ ΤΩΝ ΕΙΣΡΟΩΝ ΜΕ ΤΗ ΒΟΗΘΕΙΑ ΤΟΥ ΟΠΟΙΟΥ ΠΡΟΣΔΙΟΡΙΖΕΙ ΤΟ ΜΟΝΤΕΛΟ ΚΑΙ ΠΡΟΧΩΡΕΙ ΣΤΗ ΔΙΕΝΕΡΓΕΙΑ ΠΡΟΒΛΕΨΗΣ, - ΠΑΡΕΧΕΙ ΤΑ ΒΑΣΙΚΑ ΣΤΟΙΧΕΙΑ ΓΙΑ ΤΗΝ ΚΑΘΗΜΕΡΙΝΗ ΛΕΙΤΟΥΡΓΙΑ ΤΩΝ ΣΤΑΘΜΩΝ, ΓΙΑ ΤΟΝ ΕΤΗΣΙΟ ΕΝΕΡΓΕΙΑΚΟ ΠΡΟΥΠΟΛΟΓΙΣΜΟ ΚΑΙ ΓΙΑ ΤΟΝ ΠΡΟΓΡΑΜΜΑΤΙΣΜΟ ΕΠΕΝΔΥΣΕΩΝ ΚΑΙ ΕΠΕΚΤΑΣΗΣ ΤΟΥ ΣΥΣΤΗΜΑΤΟΣ ΠΑΡΑΓΩΓΗΣ. (ΠΕΡΙΚΟΠΗ ΠΕΡΙΛΗΨΗΣ)"]},{"key":"dc:title","label":"Title","values":["ΒΕΛΤΙΣΤΗ ΣΥΝΕΡΓΑΣΙΑ ΥΔΡΟΗΛΕΚΤΡΙΚΩΝ ΚΑΙ ΘΕΡΜΙΚΩΝ ΣΤΑΘΜΩΝ ΠΑΡΑΓΩΓΗΣ ΗΛΕΚΤΡΙΚΗΣ ΕΝΕΡΓΕΙΑΣ","OPTIMAL COOPERATION BETWEEN HYDROELECTRIC AND THERMAL PLANTS OF ELECTRIC POWER PRODUCTION"]}]}],"canonical_facts":{"dc:creator":["Καβράκος, Μιλτιάδης"],"dc:date":["1994"],"dc:description":["THE OBJECT OF THIS DOCTORALK THESIS IS THE CREATION OF AN INTEGRATED SYSTEM (NAMED \"NEREUS\") WHICH SOLVES THE PROBLEM OF LONG-TERM PLANNING OF HYDROTHERMAL COOPERATION, THAT IS THE ECONOMIC RUNNING OF A MIXED HYDROTHERMAL POWER PRODUCTION SYSTEM, WITHIN THE TIME HORIZON OF ONE YEAR. THIS VERY SYSTEM: - DEVELOPS AMODEL AND A NUMBER OF METHODS FOR SOLVING THE PROBLEM CONCERNING THE LONG-TERM PLANNING OF HYDROTHERMAL COOPERATION IN THE CASES OF REAL PRODUCTION SYSTEMS WITH SEVERAL AND VARIOUS THERMOELECTRIC AND HYDROELECTRIC PLANTS (IT COPES WITH THE ACCURATE FUEL COST FUNCTIONS OF HYDROTHERMAL PLANTS, THE CHANGING HEIGHT OF FALL IN THE HYDROELECTRIC ONES, THE CORRELATION OF THE SUCCESSIVE INFLOWS, THE TECHNICAL AND FUNCTIONAL CONSTRAINTS OF THE SYSTEM). - DETERMINES BYMEANS OF AN ORIGINAL METHOD THE OPTIMUM PUMPING LOAD, THE CORRESPONDING HYDRAULIC PRODUCTION AND THE RESULTING PROFIT FOR EACH TIME-INTERVAL. - ESTIMATES THE FUEL COST FUNCTIONS, TAKING FOR GRANTED THE MAINTENANCE PLANNING AND THE F.O.R. OF THE PLANTS. - RESEARCHES INTO THE CORRELATION OF THE INFLOWS AND SUGGESTS THE ADVISABLE TIME-INTERVALS WHICH THE ANNUAL TIME-HORIZON OF THE PROBLEM IS DIVIDED IN. - OPTIMIZES THE HYDROELECTRIC ENERGY PRODUCTION IN EACH TIME-INTERVAL AND FOR EACH HYDROELECTRIC PLANT OF THE PRODUCTION SYSTEM. - PROVIDES THE BASIC ELEMENTS FOR THE ANNUAL ENERGY BUDGET AS WELL AS FOR THE PLANNINGOF INVESTMENTS ANF OF THE EXPANSION OF THE POWER SYSTEM. - OFFERS THE POSSIBILITY FOR A REASSESSMENT AND A MODIFICATION OF THE DECISIONS THAT HAVE BEEN MADE. (ABSTRACT TRUNCATED)","ΣΤΟΧΟ ΤΗΣ ΔΙΔΑΚΤΟΡΙΚΗΣ ΔΙΑΤΡΙΒΗΣ ΑΠΟΤΕΛΕΣΕ Η ΔΗΜΙΟΥΡΓΙΑ ΕΝΟΣ ΟΛΟΚΛΗΡΩΜΕΝΟΥ ΣΥΣΤΗΜΑΤΟΣ (ΤΟ ΟΝΟΜΑ ΑΥΤΟΥ \"ΝΗΡΕΥΣ\"), ΤΟ ΟΠΟΙΟ ΑΝΤΙΜΕΤΩΠΙΖΕΙ ΤΟ ΠΡΟΒΛΗΜΑ ΤΟΥ ΜΑΚΡΟΧΡΟΝΙΟΥ ΠΡΟΓΡΑΜΜΑΤΙΣΜΟΥ ΤΗΣ ΥΔΡΟΘΕΡΜΙΚΗΣ ΣΥΝΕΡΓΑΣΙΑΣ, ΤΗΣ ΟΙΚΟΝΟΜΙΚΗΣ ΔΗΛΑΔΗΛΕΙΤΟΥΡΓΙΑΣ ΕΝΟΣ ΜΙΚΤΟΥ ΥΔΡΟΘΕΡΜΙΚΟΥ ΣΥΣΤΗΜΑΤΟΣ ΠΑΡΑΓΩΓΗΣ ΗΛΕΚΤΡΙΚΗΣ ΕΝΕΡΓΕΙΑΣ ΣΕ ΧΡΟΝΙΚΟ ΟΡΙΖΟΝΤΑ ΕΝΟΣ ΕΤΟΥΣ. ΤΟ ΣΥΣΤΗΜΑ ΑΥΤΟ - ΛΑΜΒΑΝΕΙ ΥΠΟΨΗ ΤΑ ΠΡΑΓΜΑΤΙΚΑ ΧΑΡΑΚΤΗΡΙΣΤΙΚΑ ΤΩΝ ΣΥΣΤΗΜΑΤΩΝ ΠΑΡΑΓΩΓΗΣ (ΠΡΟΓΡΑΜΜΑΤΙΣΜΕΝΗ ΣΥΝΤΗΡΗΣΗ ΚΑΙ ΑΠΡΟΒΛΕΠΤΕΣ ΔΙΑΚΟΠΕΣ ΤΗΣ ΛΕΙΤΟΥΡΓΙΑΣ ΤΩΝ ΘΕΡΜΟΗΛΕΚΤΡΙΚΩΝ ΣΤΑΘΜΩΝ, ΑΚΡΙΒΕΙΣ ΧΑΡΑΚΤΗΡΙΣΤΙΚΕΣ ΚΟΣΤΟΥΣ ΚΑΥΣΙΜΟΥ, ΥΨΟΣ ΠΤΩΣΗΣ ΤΟΥ ΝΕΡΟΥ ΣΤΟΥΣ ΥΔΡΟΗΛΕΚΤΡΙΚΟΥΣ ΣΤΑΘΜΟΥΣ, ΣΥΣΧΕΤΙΣΗ ΔΙΑΔΟΧΙΚΩΝ ΕΙΣΡΟΩΝ, ΤΕΧΝΙΚΟΥΣ ΚΑΙ ΛΕΙΤΟΥΡΓΙΚΟΥΣ ΠΕΡΙΟΡΙΣΜΟΥΣ), - ΠΡΟΣΔΙΟΡΙΖΕΙ ΤΑ ΒΕΛΤΙΣΤΑ ΑΝΤΛΗΤΙΚΑ ΦΟΡΤΙΑ, ΤΗΝ ΑΝΤΙΣΤΟΙΧΗ ΥΔΡΑΥΛΙΚΗ ΠΑΡΑΓΩΓΗ ΚΑΙ ΤΗΝ ΩΦΕΛΕΙΑ ΠΟΥ ΠΡΟΚΥΠΤΕΙ ΓΙΑ ΚΑΘΕ ΥΠΟΔΙΑΣΤΗΜΑ ΤΟΥ ΕΤΟΥΣ, - ΒΡΙΣΚΕΙ ΤΙΣΣΥΝΑΡΤΗΣΕΙΣ ΤΩΝ ΧΑΡΑΚΤΗΡΙΣΤΙΚΩΝ ΚΟΣΤΟΥΣ ΚΑΥΣΙΜΟΥ ΜΕ ΔΕΔΟΜΕΝΟ ΤΟΝ ΠΡΟΓΡΑΜΜΑΤΙΣΜΟ ΣΥΝΤΗΡΗΣΗΣ ΚΑΙ ΤΑ F.O.R. ΤΩΝ ΜΟΝΑΔΩΝ, - ΕΡΕΥΝΑ ΤΗ ΣΥΣΧΕΤΙΣΗ ΤΩΝ ΕΙΣΡΟΩΝ ΚΑΙΥΠΟΛΟΓΙΖΕΙ ΤΙΣ ΠΙΘΑΝΟΤΗΤΕΣ ΜΕΤΑΒΑΣΕΩΣ ΑΠΟ ΕΝΑ ΠΛΗΘΟΣ ΤΙΜΩΝ ΣΕ ΕΝΑ ΑΛΛΟ, ΓΙΑ ΚΑΘΕ ΥΠΟΔΙΑΣΤΗΜΑ ΤΟΥ ΕΤΟΥΣ, - ΒΕΛΤΙΣΤΟΠΟΙΕΙ ΤΗ ΠΑΡΑΓΩΓΗ ΥΔΡΟΗΛΕΚΤΡΙΚΗΣ ΕΝΕΡΓΕΙΑΣ ΓΙΑ ΚΑΘΕ ΔΥΝΑΤΗ ΤΙΜΗ ΑΠΟΘΕΜΑΤΟΣ ΚΑΙ ΕΙΣΡΟΗΣ ΣΤΑ ΕΠΙΜΕΡΟΥΣ ΦΡΑΓΜΑΤΑ, - ΣΥΝΟΔΕΥΕΤΑΙ ΑΠΟ ΕΡΓΑΛΕΙΟ ΑΞΙΟΛΟΓΗΣΗΣ ΜΟΝΤΕΛΩΝ ΠΡΟΒΛΕΨΗΣ ΤΩΝ ΕΙΣΡΟΩΝ ΜΕ ΤΗ ΒΟΗΘΕΙΑ ΤΟΥ ΟΠΟΙΟΥ ΠΡΟΣΔΙΟΡΙΖΕΙ ΤΟ ΜΟΝΤΕΛΟ ΚΑΙ ΠΡΟΧΩΡΕΙ ΣΤΗ ΔΙΕΝΕΡΓΕΙΑ ΠΡΟΒΛΕΨΗΣ, - ΠΑΡΕΧΕΙ ΤΑ ΒΑΣΙΚΑ ΣΤΟΙΧΕΙΑ ΓΙΑ ΤΗΝ ΚΑΘΗΜΕΡΙΝΗ ΛΕΙΤΟΥΡΓΙΑ ΤΩΝ ΣΤΑΘΜΩΝ, ΓΙΑ ΤΟΝ ΕΤΗΣΙΟ ΕΝΕΡΓΕΙΑΚΟ ΠΡΟΥΠΟΛΟΓΙΣΜΟ ΚΑΙ ΓΙΑ ΤΟΝ ΠΡΟΓΡΑΜΜΑΤΙΣΜΟ ΕΠΕΝΔΥΣΕΩΝ ΚΑΙ ΕΠΕΚΤΑΣΗΣ ΤΟΥ ΣΥΣΤΗΜΑΤΟΣ ΠΑΡΑΓΩΓΗΣ. (ΠΕΡΙΚΟΠΗ ΠΕΡΙΛΗΨΗΣ)"],"dc:identifier":["10.12681/eadd/3762","http://hdl.handle.net/10442/hedi/3762"],"dc:language":["gre"],"dc:publisher":["National Technical University of Athens (NTUA)","Εθνικό Μετσόβιο Πολυτεχνείο (ΕΜΠ)"],"dc:subject":["ΒΕΛΤΙΣΤΗ ΠΑΡΑΓΩΓΗ ΥΔΡΟΗΛΕΚΤΡΙΚΗΣ ΕΝΕΡΓΕΙΑΣ","ΒΕΛΤΙΣΤΟ ΑΝΤΛΗΤΙΚΟ ΦΟΡΤΙΟ","Διαχείριση νερού","ΔΥΝΑΜΙΚΟΣ/ΜΗ ΓΡΑΜΜΙΚΟΣ ΠΡΟΓΡΑΜΜΑΤΙΣΜΟΣ","Στοχαστικότητα","Υδροθερμική συνεργασία","HYDROTHERMAL COOPERATION","NON LINEAR PROGRAMMING - DYNAMICPROGRAMMING","Optimum hydroelectric energy production","OPTIMUM PUMPING LOAD","Stochastic","WATER ALLOCATION","Επιστήμες Μηχανικού και Τεχνολογία","Επιστήμη Μηχανολόγου Μηχανικού","Engineering and Technology","Mechanical Engineering"],"dc:title":["ΒΕΛΤΙΣΤΗ ΣΥΝΕΡΓΑΣΙΑ ΥΔΡΟΗΛΕΚΤΡΙΚΩΝ ΚΑΙ ΘΕΡΜΙΚΩΝ ΣΤΑΘΜΩΝ ΠΑΡΑΓΩΓΗΣ ΗΛΕΚΤΡΙΚΗΣ ΕΝΕΡΓΕΙΑΣ","OPTIMAL COOPERATION BETWEEN HYDROELECTRIC AND THERMAL PLANTS OF ELECTRIC POWER PRODUCTION"],"dc:type":["PhD Thesis"]},"updated_at":"2026-11-18T20:22:22Z"}