{"id":{"repo_id":"greece","oai_identifier":"oai:10442/40330"},"canonical_url":"https://search.ndltd.org/etd/greece/oai:10442/40330","repository":{"repo_id":"greece","name":"Greek National Archive of PhD Theses","base_url":"https://phdtheses.ekt.gr/eadd_oai/request"},"display":{"title":"Συσχέτιση κεντρικού πάχους κερατοειδούς με πάχος οπτικών ινών και των παραμέτρων της οπτικής θηλής με HRT II στην οφθαλμική υπερτονία και στους διαφόρους τύπους γλαυκώματος","abstract":"AIMS: To compare and correlate optic nerve head parameterersobtained by HRT with defects detected by short-wavelength automaticperimetry (SWAP) in eyes with ocular hypertension (OHT).METHODS: Prospective, cross-sectional study. One hundred forty sixconsecutive patients with OHT.All subjects had reliable SWAP and HRT measurements performedwithin a 2-week period. The eyes were classified as normal/abnormalaccording to visual field criteria and Moorfields regression analysis(MRA). One eye of each patient was analyzed.Correlations between visual field indices {mean deviation, patternstandard deviation (PSD) and corrected PSD} and HRT parameters wereanalyzed using Spearman correlation coefficient (r) and the agreementbetween the tests in classifying eyes was defined with k value.RESULTS: Mean age of the patients was 53±10.5years and meancentral corneal thickness (CCT) was 559±37μm. Twenty-nine eyes(19.9%) had SWAP visual field defects. Twenty nine eyes (19.9%) hadabnormal HRT evaluation. Six eyes (4.1%) had abnormal HRTevaluation and SWAP visual field defects. Another nine eyes (6.2%) had“suspicious” HRT evaluation and SWAP visual field defects. The kstatistic is 0.116 (p=0.12) and thus there is a very poor agreementbetween the methods. No statistical significant correlation between HRTand SWAP parameters was detected.CONCLUSIONS: SWAP visual field defects may coexist withabnormalities of optic disc detected by HRT in eyes with OHT. In mosteyes, however, the two methods detect different glaucoma properties.","abstract_html":"AIMS: To compare and correlate optic nerve head parameterersobtained by HRT with defects detected by short-wavelength automaticperimetry (SWAP) in eyes with ocular hypertension (OHT).METHODS: Prospective, cross-sectional study. One hundred forty sixconsecutive patients with OHT.All subjects had reliable SWAP and HRT measurements performedwithin a 2-week period. The eyes were classified as normal/abnormalaccording to visual field criteria and Moorfields regression analysis(MRA). One eye of each patient was analyzed.Correlations between visual field indices {mean deviation, patternstandard deviation (PSD) and corrected PSD} and HRT parameters wereanalyzed using Spearman correlation coefficient (r) and the agreementbetween the tests in classifying eyes was defined with k value.RESULTS: Mean age of the patients was 53±10.5years and meancentral corneal thickness (CCT) was 559±37μm. Twenty-nine eyes(19.9%) had SWAP visual field defects. Twenty nine eyes (19.9%) hadabnormal HRT evaluation. Six eyes (4.1%) had abnormal HRTevaluation and SWAP visual field defects. Another nine eyes (6.2%) had“suspicious” HRT evaluation and SWAP visual field defects. The kstatistic is 0.116 (p=0.12) and thus there is a very poor agreementbetween the methods. No statistical significant correlation between HRTand SWAP parameters was detected.CONCLUSIONS: SWAP visual field defects may coexist withabnormalities of optic disc detected by HRT in eyes with OHT. In mosteyes, however, the two methods detect different glaucoma properties.","abstract_has_math":false,"creators":["Pitsas, Christos","Πίτσας, Χρήστος"],"institution":"National and Kapodistrian University of Athens","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013","date_published":"2013","updated_at":"2026-11-18T21:29:03Z","subjects":["Γλαύκωμα","Γλαυκωματικά ελλείματα οπτικών πεδίων - περιμετρία","Βραχέους μήκους κύματος αυτόματη περιμετρία","Πάχος κεντρικού κερατοειδή","Οπτικός δίσκος","Αναλυτής οπτικής θηλής - HRT","Οφθαλμική υπερτονία","Glaucoma","Glaucomatous fields defects - perimetry","Short wavelength automatic perimetry (SWAP)","Central corneal thickness (CCT)","Optic disk","Ocular hypertension","Scanning laser ophthalmoscopy","Ιατρική και Επιστήμες Υγείας","Κλινική Ιατρική","Medical and Health Sciences","Clinical Medicine"],"languages":["gre"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["10.12681/eadd/40330"],"render_values":[{"text":"10.12681/eadd/40330","href":"https://doi.org/10.12681/eadd/40330","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10442/hedi/40330","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/10442/hedi/40330","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://phdtheses.ekt.gr/eadd_oai/request?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3A10442%2F40330","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Pitsas, Christos","Πίτσας, Χρήστος"]},{"key":"dc:creator.fathername","label":"Dc Creator Fathername","values":["Kyriakos"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2013"]},{"key":"dc:publisher","label":"Institution","values":["National and Kapodistrian University of Athens","Εθνικό και Καποδιστριακό Πανεπιστήμιο Αθηνών (ΕΚΠΑ)"]},{"key":"dc:type","label":"Dc Type","values":["PhD Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Γλαύκωμα","Γλαυκωματικά ελλείματα οπτικών πεδίων - περιμετρία","Βραχέους μήκους κύματος αυτόματη περιμετρία","Πάχος κεντρικού κερατοειδή","Οπτικός δίσκος","Αναλυτής οπτικής θηλής - HRT","Οφθαλμική υπερτονία","Glaucoma","Glaucomatous fields defects - perimetry","Short wavelength automatic perimetry (SWAP)","Central corneal thickness (CCT)","Optic disk","Ocular hypertension","Scanning laser ophthalmoscopy","Ιατρική και Επιστήμες Υγείας","Κλινική Ιατρική","Medical and Health Sciences","Clinical Medicine"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["gre"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.12681/eadd/40330","http://hdl.handle.net/10442/hedi/40330"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["AIMS: To compare and correlate optic nerve head parameterersobtained by HRT with defects detected by short-wavelength automaticperimetry (SWAP) in eyes with ocular hypertension (OHT).METHODS: Prospective, cross-sectional study. One hundred forty sixconsecutive patients with OHT.All subjects had reliable SWAP and HRT measurements performedwithin a 2-week period. The eyes were classified as normal/abnormalaccording to visual field criteria and Moorfields regression analysis(MRA). One eye of each patient was analyzed.Correlations between visual field indices {mean deviation, patternstandard deviation (PSD) and corrected PSD} and HRT parameters wereanalyzed using Spearman correlation coefficient (r) and the agreementbetween the tests in classifying eyes was defined with k value.RESULTS: Mean age of the patients was 53±10.5years and meancentral corneal thickness (CCT) was 559±37μm. Twenty-nine eyes(19.9%) had SWAP visual field defects. Twenty nine eyes (19.9%) hadabnormal HRT evaluation. Six eyes (4.1%) had abnormal HRTevaluation and SWAP visual field defects. Another nine eyes (6.2%) had“suspicious” HRT evaluation and SWAP visual field defects. The kstatistic is 0.116 (p=0.12) and thus there is a very poor agreementbetween the methods. No statistical significant correlation between HRTand SWAP parameters was detected.CONCLUSIONS: SWAP visual field defects may coexist withabnormalities of optic disc detected by HRT in eyes with OHT. In mosteyes, however, the two methods detect different glaucoma properties.","ΣΚΟΠΟΣ: Να συγκρίνουμε και να συσχετίσουμε τις παραμέτρους τηςκεφαλής του οπτικού νεύρου που λαμβάνονται με το HRT με ταελλείμματα (σκοτώματα) που εντοπίστηκαν από την short-wavelengthautomatic perimetry (SWAP) σε οφθαλμούς με οφθαλμική υπερτονία(OHT).ΜΕΘΟΟΣ: Η μελέτη περιελάμβανε με τυχαία επιλογή τον έναοφθαλμό από 146 διαδοχικούς ασθενείς με οφθαλμική υπερτονία. Όλοι οιασθενείς που περιελήφθησαν στην μελέτη είχαν αξιόπιστα οπτικά πεδία,SWAP και μετρήσεις HRT που πραγματοποιήθηκαν εντός 2 εβδομάδων.Οι οφθαλμοί κατηγοριοποιήθηκαν ως φυσιολογικοί ή παθολογικοί,σύμφωνα με τα κριτήρια του οπτικού πεδίου και του Moorfieldsregression analysis MRA για το HRT.ΑΠΟΤΕΛΕΣΜΑΤΑ: Η ανάλυση της συσχέτισης μεταξύ των δεικτώντου οπτικού πεδίου { mean deviation (MD), pattern standard deviation(PSD) και corrected pattern standard deviation (CPSD)} και τωνπαραμέτρων του HRT έγινε με τη χρήση του Spearman correlationcoefficient (r) και η συμφωνία μεταξύ των εξετάσεων, για τονχαρακτηρισμό των οφθαλμών, υπολογίστηκε με την τιμή k.Αποτελέσματα: Η μέση ηλικία των ασθενών ήταν 53 ± 10,5 χρόνια καιτο μέσο πάχους του κεντρικού κερατοειδούς (CCT) ήταν 559 ± 37 μm.Είκοσι-εννέα οφθαλμοί (19,9%) είχαν σκοτώματα στην SWAP. Είκοσιεννέα οφθαλμοί (19,9%) είχαν φυσιολογικό HRT. Έξι οφθαλμοί (4,1%)είχαν φυσιολογικό HRT και σκοτώματα στην SWAP. Άλλοι εννέαοφθαλμοί (6,2%) είχαν \"οριακό\" HRT και σκοτώματα στη SWAP .Το k statistic είναι 0,116 (ρ = 0,12), και έτσι υπάρχει μια πολύ χαμηλήσυμφωνία μεταξύ των δύο μεθόδων. εν ανιχνεύθηκε στατιστικάσημαντική συσχέτιση μεταξύ των παραμέτρων της HRT και τωνπαραμέτρων της SWAP.ΣΥΜΠΕΡΑΣΜΑΤΑ: Τα σκοτώματα στην SWAP μπορεί να συνυπάρχουν με βλάβες του οπτικού δίσκου που ανιχνεύει το HRT σεοφθαλμούς με οφθαλμική υπερτονία. Στους περισσότερους οφθαλμούς,ωστόσο, οι δύο μέθοδοι ανιχνεύουν διαφορετικές χαρακτηριστικά τουγλαυκώματος."]},{"key":"dc:title","label":"Title","values":["Συσχέτιση κεντρικού πάχους κερατοειδούς με πάχος οπτικών ινών και των παραμέτρων της οπτικής θηλής με HRT II στην οφθαλμική υπερτονία και στους διαφόρους τύπους γλαυκώματος","Correlation of central cornea thickness with retinal nerve fibers thickness and parameters of the optic disc with HRT II in ocular hypertension and in other types of glaycoma"]}]}],"canonical_facts":{"dc:creator":["Pitsas, Christos","Πίτσας, Χρήστος"],"dc:creator.fathername":["Kyriakos"],"dc:date":["2013"],"dc:description":["AIMS: To compare and correlate optic nerve head parameterersobtained by HRT with defects detected by short-wavelength automaticperimetry (SWAP) in eyes with ocular hypertension (OHT).METHODS: Prospective, cross-sectional study. One hundred forty sixconsecutive patients with OHT.All subjects had reliable SWAP and HRT measurements performedwithin a 2-week period. The eyes were classified as normal/abnormalaccording to visual field criteria and Moorfields regression analysis(MRA). One eye of each patient was analyzed.Correlations between visual field indices {mean deviation, patternstandard deviation (PSD) and corrected PSD} and HRT parameters wereanalyzed using Spearman correlation coefficient (r) and the agreementbetween the tests in classifying eyes was defined with k value.RESULTS: Mean age of the patients was 53±10.5years and meancentral corneal thickness (CCT) was 559±37μm. Twenty-nine eyes(19.9%) had SWAP visual field defects. Twenty nine eyes (19.9%) hadabnormal HRT evaluation. Six eyes (4.1%) had abnormal HRTevaluation and SWAP visual field defects. Another nine eyes (6.2%) had“suspicious” HRT evaluation and SWAP visual field defects. The kstatistic is 0.116 (p=0.12) and thus there is a very poor agreementbetween the methods. No statistical significant correlation between HRTand SWAP parameters was detected.CONCLUSIONS: SWAP visual field defects may coexist withabnormalities of optic disc detected by HRT in eyes with OHT. In mosteyes, however, the two methods detect different glaucoma properties.","ΣΚΟΠΟΣ: Να συγκρίνουμε και να συσχετίσουμε τις παραμέτρους τηςκεφαλής του οπτικού νεύρου που λαμβάνονται με το HRT με ταελλείμματα (σκοτώματα) που εντοπίστηκαν από την short-wavelengthautomatic perimetry (SWAP) σε οφθαλμούς με οφθαλμική υπερτονία(OHT).ΜΕΘΟΟΣ: Η μελέτη περιελάμβανε με τυχαία επιλογή τον έναοφθαλμό από 146 διαδοχικούς ασθενείς με οφθαλμική υπερτονία. Όλοι οιασθενείς που περιελήφθησαν στην μελέτη είχαν αξιόπιστα οπτικά πεδία,SWAP και μετρήσεις HRT που πραγματοποιήθηκαν εντός 2 εβδομάδων.Οι οφθαλμοί κατηγοριοποιήθηκαν ως φυσιολογικοί ή παθολογικοί,σύμφωνα με τα κριτήρια του οπτικού πεδίου και του Moorfieldsregression analysis MRA για το HRT.ΑΠΟΤΕΛΕΣΜΑΤΑ: Η ανάλυση της συσχέτισης μεταξύ των δεικτώντου οπτικού πεδίου { mean deviation (MD), pattern standard deviation(PSD) και corrected pattern standard deviation (CPSD)} και τωνπαραμέτρων του HRT έγινε με τη χρήση του Spearman correlationcoefficient (r) και η συμφωνία μεταξύ των εξετάσεων, για τονχαρακτηρισμό των οφθαλμών, υπολογίστηκε με την τιμή k.Αποτελέσματα: Η μέση ηλικία των ασθενών ήταν 53 ± 10,5 χρόνια καιτο μέσο πάχους του κεντρικού κερατοειδούς (CCT) ήταν 559 ± 37 μm.Είκοσι-εννέα οφθαλμοί (19,9%) είχαν σκοτώματα στην SWAP. Είκοσιεννέα οφθαλμοί (19,9%) είχαν φυσιολογικό HRT. Έξι οφθαλμοί (4,1%)είχαν φυσιολογικό HRT και σκοτώματα στην SWAP. Άλλοι εννέαοφθαλμοί (6,2%) είχαν \"οριακό\" HRT και σκοτώματα στη SWAP .Το k statistic είναι 0,116 (ρ = 0,12), και έτσι υπάρχει μια πολύ χαμηλήσυμφωνία μεταξύ των δύο μεθόδων. εν ανιχνεύθηκε στατιστικάσημαντική συσχέτιση μεταξύ των παραμέτρων της HRT και τωνπαραμέτρων της SWAP.ΣΥΜΠΕΡΑΣΜΑΤΑ: Τα σκοτώματα στην SWAP μπορεί να συνυπάρχουν με βλάβες του οπτικού δίσκου που ανιχνεύει το HRT σεοφθαλμούς με οφθαλμική υπερτονία. Στους περισσότερους οφθαλμούς,ωστόσο, οι δύο μέθοδοι ανιχνεύουν διαφορετικές χαρακτηριστικά τουγλαυκώματος."],"dc:identifier":["10.12681/eadd/40330","http://hdl.handle.net/10442/hedi/40330"],"dc:language":["gre"],"dc:publisher":["National and Kapodistrian University of Athens","Εθνικό και Καποδιστριακό Πανεπιστήμιο Αθηνών (ΕΚΠΑ)"],"dc:subject":["Γλαύκωμα","Γλαυκωματικά ελλείματα οπτικών πεδίων - περιμετρία","Βραχέους μήκους κύματος αυτόματη περιμετρία","Πάχος κεντρικού κερατοειδή","Οπτικός δίσκος","Αναλυτής οπτικής θηλής - HRT","Οφθαλμική υπερτονία","Glaucoma","Glaucomatous fields defects - perimetry","Short wavelength automatic perimetry (SWAP)","Central corneal thickness (CCT)","Optic disk","Ocular hypertension","Scanning laser ophthalmoscopy","Ιατρική και Επιστήμες Υγείας","Κλινική Ιατρική","Medical and Health Sciences","Clinical Medicine"],"dc:title":["Συσχέτιση κεντρικού πάχους κερατοειδούς με πάχος οπτικών ινών και των παραμέτρων της οπτικής θηλής με HRT II στην οφθαλμική υπερτονία και στους διαφόρους τύπους γλαυκώματος","Correlation of central cornea thickness with retinal nerve fibers thickness and parameters of the optic disc with HRT II in ocular hypertension and in other types of glaycoma"],"dc:type":["PhD Thesis"]},"updated_at":"2026-11-18T21:29:03Z"}