{"id":{"repo_id":"greece","oai_identifier":"oai:10442/44668"},"canonical_url":"https://search.ndltd.org/etd/greece/oai:10442/44668","repository":{"repo_id":"greece","name":"Greek National Archive of PhD Theses","base_url":"https://phdtheses.ekt.gr/eadd_oai/request"},"display":{"title":"Πειραματική μελέτη της ανάπτυξης συμφύσεων μετά την τοποθέτηση ενδοπεριτοναϊκά διαφόρων πλαστικών υλικών","abstract":"Background. Adhesion formation caused by the use of foreign materials is a major medical and financial problem. The aim of this study is to compare the histological findings in intraperitoneal adhesion development due to long standing tubes, used in common surgical practice, in a rat model. Methods. Pieces of Polyurethane, Teflon, Silicone and Polyvinyl Chloride (PVC) from commercial available intravenous catheters (7F) were placed intraperitoneally in thirty-six female Wistar rats randomly assigned to four groups. Three months later, histologic evaluation by two independent pathologists was done blindly. The number of organs involved was examined, and the degree of inflammatory infiltration, thickness, extent and density of the adhesions were graded in a score system. Results. The overall adhesion score differed significantly (p<0.01) among the groups, the highest being in the Teflon group (mean: 13.2), followed by the PVC group (10), the silicone group (9.6) and the polyurethane group which was the lowest (6.8). Discussion. Polyurethane caused the least adhesion development in this experimental model than the other materials and therefore can be used more extensively for the construction of catheters for intraperitoneal use. This is clinically important in cases where indwelling intra-peritoneal catheters for prolonged use are necessary.","abstract_html":"Background. Adhesion formation caused by the use of foreign materials is a major medical and financial problem. The aim of this study is to compare the histological findings in intraperitoneal adhesion development due to long standing tubes, used in common surgical practice, in a rat model. Methods. Pieces of Polyurethane, Teflon, Silicone and Polyvinyl Chloride (PVC) from commercial available intravenous catheters (7F) were placed intraperitoneally in thirty-six female Wistar rats randomly assigned to four groups. Three months later, histologic evaluation by two independent pathologists was done blindly. The number of organs involved was examined, and the degree of inflammatory infiltration, thickness, extent and density of the adhesions were graded in a score system. Results. The overall adhesion score differed significantly (p&lt;0.01) among the groups, the highest being in the Teflon group (mean: 13.2), followed by the PVC group (10), the silicone group (9.6) and the polyurethane group which was the lowest (6.8). Discussion. Polyurethane caused the least adhesion development in this experimental model than the other materials and therefore can be used more extensively for the construction of catheters for intraperitoneal use. This is clinically important in cases where indwelling intra-peritoneal catheters for prolonged use are necessary.","abstract_has_math":false,"creators":["Simeondiis, Kreon","Συμεωνίδης, Κρέων"],"institution":"National and Kapodistrian University of Athens","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013","date_published":"2013","updated_at":"2026-11-18T21:34:53Z","subjects":["Καθετήρες","Ενδοπεριτοναϊκές συμφύσεις","Πολυμερή υλικά","Πολυουρεθάνιο","Πολυβινυλοχλωρίδιο","Σιλικόνη","Τεφλόν","Catheters","Intraperitoneal adhesions","Polymeric materials","Polyurethane","Polyvinylchloride","Silicone","Teflon","Adhesions","Ιατρική και Επιστήμες Υγείας","Βασική Ιατρική","Κλινική Ιατρική","Medical and Health Sciences","Basic Medicine","Clinical Medicine"],"languages":["gre"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["10.12681/eadd/44668"],"render_values":[{"text":"10.12681/eadd/44668","href":"https://doi.org/10.12681/eadd/44668","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10442/hedi/44668","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/10442/hedi/44668","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://phdtheses.ekt.gr/eadd_oai/request?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3A10442%2F44668","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Simeondiis, Kreon","Συμεωνίδης, Κρέων"]},{"key":"dc:creator.fathername","label":"Dc Creator Fathername","values":["Maximos"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2013"]},{"key":"dc:publisher","label":"Institution","values":["National and Kapodistrian University of Athens","Εθνικό και Καποδιστριακό Πανεπιστήμιο Αθηνών (ΕΚΠΑ)"]},{"key":"dc:type","label":"Dc Type","values":["PhD Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Καθετήρες","Ενδοπεριτοναϊκές συμφύσεις","Πολυμερή υλικά","Πολυουρεθάνιο","Πολυβινυλοχλωρίδιο","Σιλικόνη","Τεφλόν","Catheters","Intraperitoneal adhesions","Polymeric materials","Polyurethane","Polyvinylchloride","Silicone","Teflon","Adhesions","Ιατρική και Επιστήμες Υγείας","Βασική Ιατρική","Κλινική Ιατρική","Medical and Health Sciences","Basic Medicine","Clinical Medicine"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["gre"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.12681/eadd/44668","http://hdl.handle.net/10442/hedi/44668"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Background. Adhesion formation caused by the use of foreign materials is a major medical and financial problem. The aim of this study is to compare the histological findings in intraperitoneal adhesion development due to long standing tubes, used in common surgical practice, in a rat model. Methods. Pieces of Polyurethane, Teflon, Silicone and Polyvinyl Chloride (PVC) from commercial available intravenous catheters (7F) were placed intraperitoneally in thirty-six female Wistar rats randomly assigned to four groups. Three months later, histologic evaluation by two independent pathologists was done blindly. The number of organs involved was examined, and the degree of inflammatory infiltration, thickness, extent and density of the adhesions were graded in a score system. Results. The overall adhesion score differed significantly (p<0.01) among the groups, the highest being in the Teflon group (mean: 13.2), followed by the PVC group (10), the silicone group (9.6) and the polyurethane group which was the lowest (6.8). Discussion. Polyurethane caused the least adhesion development in this experimental model than the other materials and therefore can be used more extensively for the construction of catheters for intraperitoneal use. This is clinically important in cases where indwelling intra-peritoneal catheters for prolonged use are necessary.","Σκοπός της μελέτης είναι η σύγκριση της δημιουργίας συμφύσεων, σε ένα πειραματικό μοντέλο, μετά από την ενδοπεριτοναϊκή τοποθέτηση τεσσάρων υλικών, τα οποία χρησιμοποιούνται για τη κατασκευή ενδοπεριτοναϊκών καθετήρων. Τμήματα πολυουρεθανίου, τεφλόν, σιλικόνης και πολυβινυλοχλωριδίου (PVC) τοποθετήθηκαν ενδοπεριτοναϊκά σε 36 θηλυκούς αρουραίους τύπου Wistar. Η ανάπτυξη συμφύσεων εκτιμήθηκε ποσοτικά με τη κλίμακα Nair. To πολυουρεθάνιο προκάλεσε το μικρότερο σχηματισμό συμφύσεων ενώ υψηλότερη βαθμολογία στη κλίμακα Nair έλαβαν τα πειραματόζωα της ομάδας πολυβινυλοχλωριδίου PVC. Όταν συγκρίναμε το πάχος και τη σταθερότητα των συμφύσεων ανάμεσα στις τέσσερις ομάδες, παρατηρήθηκαν σημαντικές διαφορές, με την ομάδα του πολυουρεθανίου να παρουσιάζει λεπτές και χαλαρές συμφύσεις. Αντίθετα, σχεδόν όλα τα πειραματόζωα της ομάδας τεφλόν ανέπτυξαν παχιές και πυκνές συμφύσεις. Συμπερασματικά, το πολυουρεθάνιο προκάλεσε τη μικρότερη δημιουργία συμφύσεων σε σχέση με τα υπόλοιπα υλικά και μπορεί να χρησιμοποιηθεί ευρύτερα για τη κατασκευή ενδοπεριτοναϊκών καθετήρων παρατεταμένης χρήσης."]},{"key":"dc:title","label":"Title","values":["Πειραματική μελέτη της ανάπτυξης συμφύσεων μετά την τοποθέτηση ενδοπεριτοναϊκά διαφόρων πλαστικών υλικών","Adhesion formation and intraperitoneal catheters: experimental study"]}]}],"canonical_facts":{"dc:creator":["Simeondiis, Kreon","Συμεωνίδης, Κρέων"],"dc:creator.fathername":["Maximos"],"dc:date":["2013"],"dc:description":["Background. Adhesion formation caused by the use of foreign materials is a major medical and financial problem. The aim of this study is to compare the histological findings in intraperitoneal adhesion development due to long standing tubes, used in common surgical practice, in a rat model. Methods. Pieces of Polyurethane, Teflon, Silicone and Polyvinyl Chloride (PVC) from commercial available intravenous catheters (7F) were placed intraperitoneally in thirty-six female Wistar rats randomly assigned to four groups. Three months later, histologic evaluation by two independent pathologists was done blindly. The number of organs involved was examined, and the degree of inflammatory infiltration, thickness, extent and density of the adhesions were graded in a score system. Results. The overall adhesion score differed significantly (p<0.01) among the groups, the highest being in the Teflon group (mean: 13.2), followed by the PVC group (10), the silicone group (9.6) and the polyurethane group which was the lowest (6.8). Discussion. Polyurethane caused the least adhesion development in this experimental model than the other materials and therefore can be used more extensively for the construction of catheters for intraperitoneal use. This is clinically important in cases where indwelling intra-peritoneal catheters for prolonged use are necessary.","Σκοπός της μελέτης είναι η σύγκριση της δημιουργίας συμφύσεων, σε ένα πειραματικό μοντέλο, μετά από την ενδοπεριτοναϊκή τοποθέτηση τεσσάρων υλικών, τα οποία χρησιμοποιούνται για τη κατασκευή ενδοπεριτοναϊκών καθετήρων. Τμήματα πολυουρεθανίου, τεφλόν, σιλικόνης και πολυβινυλοχλωριδίου (PVC) τοποθετήθηκαν ενδοπεριτοναϊκά σε 36 θηλυκούς αρουραίους τύπου Wistar. Η ανάπτυξη συμφύσεων εκτιμήθηκε ποσοτικά με τη κλίμακα Nair. To πολυουρεθάνιο προκάλεσε το μικρότερο σχηματισμό συμφύσεων ενώ υψηλότερη βαθμολογία στη κλίμακα Nair έλαβαν τα πειραματόζωα της ομάδας πολυβινυλοχλωριδίου PVC. Όταν συγκρίναμε το πάχος και τη σταθερότητα των συμφύσεων ανάμεσα στις τέσσερις ομάδες, παρατηρήθηκαν σημαντικές διαφορές, με την ομάδα του πολυουρεθανίου να παρουσιάζει λεπτές και χαλαρές συμφύσεις. Αντίθετα, σχεδόν όλα τα πειραματόζωα της ομάδας τεφλόν ανέπτυξαν παχιές και πυκνές συμφύσεις. Συμπερασματικά, το πολυουρεθάνιο προκάλεσε τη μικρότερη δημιουργία συμφύσεων σε σχέση με τα υπόλοιπα υλικά και μπορεί να χρησιμοποιηθεί ευρύτερα για τη κατασκευή ενδοπεριτοναϊκών καθετήρων παρατεταμένης χρήσης."],"dc:identifier":["10.12681/eadd/44668","http://hdl.handle.net/10442/hedi/44668"],"dc:language":["gre"],"dc:publisher":["National and Kapodistrian University of Athens","Εθνικό και Καποδιστριακό Πανεπιστήμιο Αθηνών (ΕΚΠΑ)"],"dc:subject":["Καθετήρες","Ενδοπεριτοναϊκές συμφύσεις","Πολυμερή υλικά","Πολυουρεθάνιο","Πολυβινυλοχλωρίδιο","Σιλικόνη","Τεφλόν","Catheters","Intraperitoneal adhesions","Polymeric materials","Polyurethane","Polyvinylchloride","Silicone","Teflon","Adhesions","Ιατρική και Επιστήμες Υγείας","Βασική Ιατρική","Κλινική Ιατρική","Medical and Health Sciences","Basic Medicine","Clinical Medicine"],"dc:title":["Πειραματική μελέτη της ανάπτυξης συμφύσεων μετά την τοποθέτηση ενδοπεριτοναϊκά διαφόρων πλαστικών υλικών","Adhesion formation and intraperitoneal catheters: experimental study"],"dc:type":["PhD Thesis"]},"updated_at":"2026-11-18T21:34:53Z"}