{"id":{"repo_id":"greece","oai_identifier":"oai:10442/47502"},"canonical_url":"https://search.ndltd.org/etd/greece/oai:10442/47502","repository":{"repo_id":"greece","name":"Greek National Archive of PhD Theses","base_url":"https://phdtheses.ekt.gr/eadd_oai/request"},"display":{"title":"Μελέτη με προσομοίωση Monte Carlo της επίδρασης των τεχνικών παραμέτρων αξονικού τομογράφου διπλής πηγής-διπλής ενέργειας στην ποιότητα εικόνας και στη δόση με σκοπό τη δημιουργία σύγχρονου εκπαιδευτικού εργαλείου","abstract":"In the present study, a Dual-Source Computed Tomography (DSCT) scanner was simulated in order to examine the possibility of using it as a dosimetric tool and to create educational scenarios in Medical Physics. The aim of the system simulation, based on the Monte Carlo N-particle radiation code (MCNP), was to develop a model that approximates the actual system reliably. The simulation of a DSCT scanner could provide a powerful tool for dose assessment and support the training of clinical scientists in the imaging performance characteristics of Computed Tomography. Subsequently, problem-based scenarios for dosimetry and study of technical parameters on image quality were implemented and evaluated. The design and development of problem-based scenarios with the use of OpenLabyrinth targeted at the creation of a modern educational tool in Medical Physics.","abstract_html":"In the present study, a Dual-Source Computed Tomography (DSCT) scanner was simulated in order to examine the possibility of using it as a dosimetric tool and to create educational scenarios in Medical Physics. The aim of the system simulation, based on the Monte Carlo N-particle radiation code (MCNP), was to develop a model that approximates the actual system reliably. The simulation of a DSCT scanner could provide a powerful tool for dose assessment and support the training of clinical scientists in the imaging performance characteristics of Computed Tomography. Subsequently, problem-based scenarios for dosimetry and study of technical parameters on image quality were implemented and evaluated. The design and development of problem-based scenarios with the use of OpenLabyrinth targeted at the creation of a modern educational tool in Medical Physics.","abstract_has_math":false,"creators":["Chantzi, Stefania","Χαντζή, Στεφανία"],"institution":"Aristotle University Of Thessaloniki (AUTH)","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2020,"date_issued":"2020","date_published":"2020","updated_at":"2026-11-18T21:38:40Z","subjects":["Υπολογιστικός τομογράφος διπλής πηγής – διπλής ενέργειας","Προσομοίωση Monte Carlo","Ηλεκτρονικό εκπαιδευτικό εργαλείο","Dual source - dual energy computed tomography scanner","Monte Carlo simulation","Digital educational tools","Φυσική","Φυσικές Επιστήμες","Εφαρμοσμένη φυσική","Επιστήμη Ηλεκτρονικών Υπολογιστών και Πληροφορική","Διεπιστημονικές εφαρμογές επιστήμης ηλεκτρονικών υπολογιστών","Physical Sciences","Natural Sciences","Applied Physics","Computer and Information Sciences","Computer Science Interdisciplinary Applications"],"languages":["gre"],"rights":["BY_NC_SA"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["10.12681/eadd/47502"],"render_values":[{"text":"10.12681/eadd/47502","href":"https://doi.org/10.12681/eadd/47502","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10442/hedi/47502","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/10442/hedi/47502","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://phdtheses.ekt.gr/eadd_oai/request?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3A10442%2F47502","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Chantzi, Stefania","Χαντζή, Στεφανία"]},{"key":"dc:creator.fathername","label":"Dc Creator Fathername","values":["Lazaros"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2020"]},{"key":"dc:publisher","label":"Institution","values":["Aristotle University Of Thessaloniki (AUTH)","Αριστοτέλειο Πανεπιστήμιο Θεσσαλονίκης (ΑΠΘ)"]},{"key":"dc:type","label":"Dc Type","values":["PhD Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Υπολογιστικός τομογράφος διπλής πηγής – διπλής ενέργειας","Προσομοίωση Monte Carlo","Ηλεκτρονικό εκπαιδευτικό εργαλείο","Dual source - dual energy computed tomography scanner","Monte Carlo simulation","Digital educational tools","Φυσική","Φυσικές Επιστήμες","Εφαρμοσμένη φυσική","Επιστήμη Ηλεκτρονικών Υπολογιστών και Πληροφορική","Διεπιστημονικές εφαρμογές επιστήμης ηλεκτρονικών υπολογιστών","Physical Sciences","Natural Sciences","Applied Physics","Computer and Information Sciences","Computer Science Interdisciplinary Applications"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["gre"]},{"key":"dc:rights","label":"Dc Rights","values":["BY_NC_SA"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.12681/eadd/47502","http://hdl.handle.net/10442/hedi/47502"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["In the present study, a Dual-Source Computed Tomography (DSCT) scanner was simulated in order to examine the possibility of using it as a dosimetric tool and to create educational scenarios in Medical Physics. The aim of the system simulation, based on the Monte Carlo N-particle radiation code (MCNP), was to develop a model that approximates the actual system reliably. The simulation of a DSCT scanner could provide a powerful tool for dose assessment and support the training of clinical scientists in the imaging performance characteristics of Computed Tomography. Subsequently, problem-based scenarios for dosimetry and study of technical parameters on image quality were implemented and evaluated. The design and development of problem-based scenarios with the use of OpenLabyrinth targeted at the creation of a modern educational tool in Medical Physics.","Στην παρούσα μελέτη προσομοιώθηκε ο υπολογιστικός τομογράφος διπλής πηγής-διπλής ενέργειας με σκοπό τη διερεύνηση της χρήσης του ως εργαλείο δοσιμετρίας καθώς και το σχεδιασμό εκπαιδευτικών σεναρίων στην Ιατρική Φυσική. Στόχος της προσομοίωσης του συστήματος, με βάση τον κώδικα μεταφοράς ακτινοβολίας Monte Carlo N-particle (MCNP), ήταν η κατασκευή ενός μοντέλου που να προσεγγίζει σε ικανοποιητικό βαθμό και με αξιοπιστία το πραγματικό σύστημα. Η προσομοίωση του συγκεκριμένου τομογράφου είχε σκοπό τη δημιουργία σύγχρονου εκπαιδευτικού εργαλείου. Για την επίτευξη αυτού του σκοπού υλοποιήθηκαν και αξιολογήθηκαν προβληματο-κεντρικά σενάρια σχετικά με τη δοσιμετρία και την επίδραση τεχνικών παραμέτρων στην ποιότητα της εικόνας. Ο σχεδιασμός και η ανάπτυξη των εκπαιδευτικών σεναρίων έγινε με τη χρήση του καινοτόμου συστήματος OpenLabyrinth."]},{"key":"dc:title","label":"Title","values":["Μελέτη με προσομοίωση Monte Carlo της επίδρασης των τεχνικών παραμέτρων αξονικού τομογράφου διπλής πηγής-διπλής ενέργειας στην ποιότητα εικόνας και στη δόση με σκοπό τη δημιουργία σύγχρονου εκπαιδευτικού εργαλείου","Monte Carlo simulation of the effect of technical parameters of dual source - dual energy computed tomography scanner in image quality and dose in order to create a modern educational tool"]}]}],"canonical_facts":{"dc:creator":["Chantzi, Stefania","Χαντζή, Στεφανία"],"dc:creator.fathername":["Lazaros"],"dc:date":["2020"],"dc:description":["In the present study, a Dual-Source Computed Tomography (DSCT) scanner was simulated in order to examine the possibility of using it as a dosimetric tool and to create educational scenarios in Medical Physics. The aim of the system simulation, based on the Monte Carlo N-particle radiation code (MCNP), was to develop a model that approximates the actual system reliably. The simulation of a DSCT scanner could provide a powerful tool for dose assessment and support the training of clinical scientists in the imaging performance characteristics of Computed Tomography. Subsequently, problem-based scenarios for dosimetry and study of technical parameters on image quality were implemented and evaluated. The design and development of problem-based scenarios with the use of OpenLabyrinth targeted at the creation of a modern educational tool in Medical Physics.","Στην παρούσα μελέτη προσομοιώθηκε ο υπολογιστικός τομογράφος διπλής πηγής-διπλής ενέργειας με σκοπό τη διερεύνηση της χρήσης του ως εργαλείο δοσιμετρίας καθώς και το σχεδιασμό εκπαιδευτικών σεναρίων στην Ιατρική Φυσική. Στόχος της προσομοίωσης του συστήματος, με βάση τον κώδικα μεταφοράς ακτινοβολίας Monte Carlo N-particle (MCNP), ήταν η κατασκευή ενός μοντέλου που να προσεγγίζει σε ικανοποιητικό βαθμό και με αξιοπιστία το πραγματικό σύστημα. Η προσομοίωση του συγκεκριμένου τομογράφου είχε σκοπό τη δημιουργία σύγχρονου εκπαιδευτικού εργαλείου. Για την επίτευξη αυτού του σκοπού υλοποιήθηκαν και αξιολογήθηκαν προβληματο-κεντρικά σενάρια σχετικά με τη δοσιμετρία και την επίδραση τεχνικών παραμέτρων στην ποιότητα της εικόνας. Ο σχεδιασμός και η ανάπτυξη των εκπαιδευτικών σεναρίων έγινε με τη χρήση του καινοτόμου συστήματος OpenLabyrinth."],"dc:identifier":["10.12681/eadd/47502","http://hdl.handle.net/10442/hedi/47502"],"dc:language":["gre"],"dc:publisher":["Aristotle University Of Thessaloniki (AUTH)","Αριστοτέλειο Πανεπιστήμιο Θεσσαλονίκης (ΑΠΘ)"],"dc:rights":["BY_NC_SA"],"dc:subject":["Υπολογιστικός τομογράφος διπλής πηγής – διπλής ενέργειας","Προσομοίωση Monte Carlo","Ηλεκτρονικό εκπαιδευτικό εργαλείο","Dual source - dual energy computed tomography scanner","Monte Carlo simulation","Digital educational tools","Φυσική","Φυσικές Επιστήμες","Εφαρμοσμένη φυσική","Επιστήμη Ηλεκτρονικών Υπολογιστών και Πληροφορική","Διεπιστημονικές εφαρμογές επιστήμης ηλεκτρονικών υπολογιστών","Physical Sciences","Natural Sciences","Applied Physics","Computer and Information Sciences","Computer Science Interdisciplinary Applications"],"dc:title":["Μελέτη με προσομοίωση Monte Carlo της επίδρασης των τεχνικών παραμέτρων αξονικού τομογράφου διπλής πηγής-διπλής ενέργειας στην ποιότητα εικόνας και στη δόση με σκοπό τη δημιουργία σύγχρονου εκπαιδευτικού εργαλείου","Monte Carlo simulation of the effect of technical parameters of dual source - dual energy computed tomography scanner in image quality and dose in order to create a modern educational tool"],"dc:type":["PhD Thesis"]},"updated_at":"2026-11-18T21:38:40Z"}