{"id":{"repo_id":"greece","oai_identifier":"oai:10442/49453"},"canonical_url":"https://search.ndltd.org/etd/greece/oai:10442/49453","repository":{"repo_id":"greece","name":"Greek National Archive of PhD Theses","base_url":"https://phdtheses.ekt.gr/eadd_oai/request"},"display":{"title":"Συγκριτική μελέτη δύο σχημάτων ινσουλινοθεραπείας σε ασθενείς με σακχαρώδη διαβήτη τύπου 2 με την χρήση αισθητήρων γλυκόζης","abstract":"Aim: To compare in terms of glycemic variability two premixed insulins, Premixed HumanInsulin 30/70 (PHI) and Biphasic Aspart 30 (BiAsp30), using Continuous Glucose Monitoring (CGM)and to estimate the correlation of Glycated Albumin (GA) and Fructosamine (FA) with CGM data.Patients-Data: A total of 36 well-controlled patients with type 2 Diabetes Mellitus (T2DM) underwent7-day CGM with PHI and subsequently with BiAsp30. GA and FA were measured at the first and lastday of each week of CGM. Results: BiAsp30 was associated with lower Average Blood Glucose(ABG) during the 23:00–03:00 period (PHI: 135.08 28.94 mg/dL, BiAsp30: 117.75 21.24 mg/dL,p < 0.001) and the 00:00–06:00 period (PHI: 120.42 23.13 mg/dL, BiAsp30: 111.17 14.74 mg/dL,p = 0.008), as well as with more time below range (<70 mg/dL) (TBR) during the 23:00–03:00 periodin the week (PHI: 3.65 5.93%, BiAsp30: 11.12 16.07%, p = 0.005). PHI was associated withlower ABG before breakfast (PHI: 111.75 23.9 mg/dL, BiAsp30: 128.25 35.9 mg/dL, p = 0.013).There were no differences between the two groups in ABG, Time In Range and Time Below Rangeduring the entire 24-h period for 7 days, p = 0.502, p = 0.534, and p = 0.258 respectively, and inTBR for the 00:00–06:00 period p = 0.253. Total daily insulin requirements were higher for BiAsp30(PHI: 47.92 12.18 IU, BiAsp30: 49.58 14.12 IU, p = 0.001). GA and FA correlated significantlywith ABG (GA: r = 0.512, p = 0.011, FA: r = 0.555, p = 0.005). Conclusions: In well-controlled patientswith T2DM, BiAsp30 is an equally effective alternative to PHI.","abstract_html":"Aim: To compare in terms of glycemic variability two premixed insulins, Premixed HumanInsulin 30/70 (PHI) and Biphasic Aspart 30 (BiAsp30), using Continuous Glucose Monitoring (CGM)and to estimate the correlation of Glycated Albumin (GA) and Fructosamine (FA) with CGM data.Patients-Data: A total of 36 well-controlled patients with type 2 Diabetes Mellitus (T2DM) underwent7-day CGM with PHI and subsequently with BiAsp30. GA and FA were measured at the first and lastday of each week of CGM. Results: BiAsp30 was associated with lower Average Blood Glucose(ABG) during the 23:00–03:00 period (PHI: 135.08 28.94 mg/dL, BiAsp30: 117.75 21.24 mg/dL,p &lt; 0.001) and the 00:00–06:00 period (PHI: 120.42 23.13 mg/dL, BiAsp30: 111.17 14.74 mg/dL,p = 0.008), as well as with more time below range (&lt;70 mg/dL) (TBR) during the 23:00–03:00 periodin the week (PHI: 3.65 5.93%, BiAsp30: 11.12 16.07%, p = 0.005). PHI was associated withlower ABG before breakfast (PHI: 111.75 23.9 mg/dL, BiAsp30: 128.25 35.9 mg/dL, p = 0.013).There were no differences between the two groups in ABG, Time In Range and Time Below Rangeduring the entire 24-h period for 7 days, p = 0.502, p = 0.534, and p = 0.258 respectively, and inTBR for the 00:00–06:00 period p = 0.253. Total daily insulin requirements were higher for BiAsp30(PHI: 47.92 12.18 IU, BiAsp30: 49.58 14.12 IU, p = 0.001). GA and FA correlated significantlywith ABG (GA: r = 0.512, p = 0.011, FA: r = 0.555, p = 0.005). Conclusions: In well-controlled patientswith T2DM, BiAsp30 is an equally effective alternative to PHI.","abstract_has_math":false,"creators":["Margaritidis, Charalampos","Μαργαριτίδης, Χαράλαμπος"],"institution":"Aristotle University Of Thessaloniki (AUTH)","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2021,"date_issued":"2021","date_published":"2021","updated_at":"2026-11-18T21:40:42Z","subjects":["Αισθητήρες γλυκόζης","Συνεχής καταγραφή γλυκόζης","Μίγματα ινσουλίνης","Σακχαρώδης Διαβήτης (ΣΔ)","Glucose sensors","Continuous Glucose Monitoring","Premixed insulins","Diabetes mellitus","Κλινική Ιατρική","Ιατρική και Επιστήμες Υγείας","Ενδοκρινολογία, Διαβήτης και Μεταβολισμός","Γενική και Εσωτερική ιατρική","Clinical Medicine","Medical and Health Sciences","Endocrinology, Diabetes and Metabolism","General and Internal Medicine"],"languages":["gre"],"rights":["BY_NC_ND_4_0"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["10.12681/eadd/49453"],"render_values":[{"text":"10.12681/eadd/49453","href":"https://doi.org/10.12681/eadd/49453","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10442/hedi/49453","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/10442/hedi/49453","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://phdtheses.ekt.gr/eadd_oai/request?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3A10442%2F49453","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Margaritidis, Charalampos","Μαργαριτίδης, Χαράλαμπος"]},{"key":"dc:creator.fathername","label":"Dc Creator Fathername","values":["Athanasios"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2021"]},{"key":"dc:publisher","label":"Institution","values":["Aristotle University Of Thessaloniki (AUTH)","Αριστοτέλειο Πανεπιστήμιο Θεσσαλονίκης (ΑΠΘ)"]},{"key":"dc:type","label":"Dc Type","values":["PhD Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Αισθητήρες γλυκόζης","Συνεχής καταγραφή γλυκόζης","Μίγματα ινσουλίνης","Σακχαρώδης Διαβήτης (ΣΔ)","Glucose sensors","Continuous Glucose Monitoring","Premixed insulins","Diabetes mellitus","Κλινική Ιατρική","Ιατρική και Επιστήμες Υγείας","Ενδοκρινολογία, Διαβήτης και Μεταβολισμός","Γενική και Εσωτερική ιατρική","Clinical Medicine","Medical and Health Sciences","Endocrinology, Diabetes and Metabolism","General and Internal Medicine"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["gre"]},{"key":"dc:rights","label":"Dc Rights","values":["BY_NC_ND_4_0"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.12681/eadd/49453","http://hdl.handle.net/10442/hedi/49453"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Aim: To compare in terms of glycemic variability two premixed insulins, Premixed HumanInsulin 30/70 (PHI) and Biphasic Aspart 30 (BiAsp30), using Continuous Glucose Monitoring (CGM)and to estimate the correlation of Glycated Albumin (GA) and Fructosamine (FA) with CGM data.Patients-Data: A total of 36 well-controlled patients with type 2 Diabetes Mellitus (T2DM) underwent7-day CGM with PHI and subsequently with BiAsp30. GA and FA were measured at the first and lastday of each week of CGM. Results: BiAsp30 was associated with lower Average Blood Glucose(ABG) during the 23:00–03:00 period (PHI: 135.08 28.94 mg/dL, BiAsp30: 117.75 21.24 mg/dL,p < 0.001) and the 00:00–06:00 period (PHI: 120.42 23.13 mg/dL, BiAsp30: 111.17 14.74 mg/dL,p = 0.008), as well as with more time below range (<70 mg/dL) (TBR) during the 23:00–03:00 periodin the week (PHI: 3.65 5.93%, BiAsp30: 11.12 16.07%, p = 0.005). PHI was associated withlower ABG before breakfast (PHI: 111.75 23.9 mg/dL, BiAsp30: 128.25 35.9 mg/dL, p = 0.013).There were no differences between the two groups in ABG, Time In Range and Time Below Rangeduring the entire 24-h period for 7 days, p = 0.502, p = 0.534, and p = 0.258 respectively, and inTBR for the 00:00–06:00 period p = 0.253. Total daily insulin requirements were higher for BiAsp30(PHI: 47.92 12.18 IU, BiAsp30: 49.58 14.12 IU, p = 0.001). GA and FA correlated significantlywith ABG (GA: r = 0.512, p = 0.011, FA: r = 0.555, p = 0.005). Conclusions: In well-controlled patientswith T2DM, BiAsp30 is an equally effective alternative to PHI.","ΣΚΟΠΟΣ: Η συγκριτική μελέτη δύο σχημάτων ινσουλινοθεραπείας (μίγμα ανθρώπινης ινσουλίνης 30/70-PIΗ και μίγμα ανάλογου-PAI, και συγκεκριμένα διφασική ινσουλίνη Aspart 30/70-Biasp30) με τη χρήση αισθητήρων γλυκόζης, και εκτίμηση της συσχέτισης της γλυκοζυλιωμένης αιμοσφαιρίνης (HbA1c), της γλυκοζυλιωμένης αλβουμίνης(GA) και της φρουκτοζαμίνης(FA) με τα δεδομένα της συνεχούς καταγραφής(CGM). ΑΣΘΕΝΕΙΣ-ΜΕΘΟΔΟΙ: Μια cross-over μελέτη σε 36 καλά ρυθμισμένα άτομα με Σακχαρώδη Διαβήτη τύπου 2 (ΣΔτ2), οι οποίοι υποβλήθηκαν σε 7ήμερη CGM με το PHI και στη συνέχεια με το Biasp30. ΑΠΟΤΕΛΕΣΜΑΤΑ: Το Biasp30 πέτυχε χαμηλότερη μέση τιμή γλυκόζης (Average Blood Glucose- ABG) για το διάστημα 23:00-03:00 (PHI: 135.08± 28.94mg/dl, Biasp30: 117.75± 21.24 mg/dl, p<0.001) και το διάστημα 00:00-06:00 (PHI: 120.42 ±23.13mg/dl, Biasp30: 111.17± 14.74, p=0.008, περισσότερο χρόνο σε επίπεδα γλυκόζης κάτω από το όριο των 70mg/dl (Time Below Range-TBR) για το διάστημα 23:00-03:00 (PHI: 58.75 ± 99.49min, Biasp30: 179.17 ± 249.30min,p=0.003). Το PHI πέτυχε χαμηλότερη ABG πριν το πρωινό (PHI: 111.75± 23.9 mg/dl, Biasp30: 128.25± 35.9mg/dl, p=0.013). Δεν υπήρξαν διαφορές μεταξύ των δύο ομάδων στην ABG για το συνολικό διάστημα του 24ώρου (PHI: 140.08± 20.71mg/dl, Biasp30:138.08± 17.93mg/dl,p=0.502), στο χρόνο εντός του στόχου (Time In Range -TIR-% του συνολικού χρόνου καταγραφής) (PHI: 75.92± 12.42%, Biasp30:74.17± 15.90%, p=0.534) και στο συνολικό TBR (% of the total CGM time) (PHI: 4.17± 3.55%, Biasp30: 5.5± 3.40%, p=0.063),και στο TBR για το διάστημα 00:00-06:00 period (PHI: 8.45 ± 8.81%, Biasp30: 12.08 ± 16.13%, p=0.253). Οι συνολικές μονάδες ινσουλίνης ήταν περισσότερες με το Biasp30(PHI: 47.92± 12.18 IU, Biasp30:49.58± 14.12 IU, p=0.001). HbA1c, GA and FA εμφάνισαν στατιστικά σημαντική συσχέτιση με την ABG (GA: r=0.512, p=0.011, FA: r=0.555, p=0.005, HbA1c: r=0.642, p=0.001).ΣΥΜΠΕΡΑΣΜΑΤΑ: Σε καλά ρυθμισμένους ασθενείς με ΣΔτ2 τα PIA και αποτελούν ισάξιες επιλογές με τα PHI. Από τους διάφορους δείκτες γλυκαιμικής μεταβλητότητας η HbA1c παρουσιάζει την ισχυρότερη συσχέτιση με την ABG."]},{"key":"dc:title","label":"Title","values":["Συγκριτική μελέτη δύο σχημάτων ινσουλινοθεραπείας σε ασθενείς με σακχαρώδη διαβήτη τύπου 2 με την χρήση αισθητήρων γλυκόζης","Comparison of premixed human insulin 30/70 to biphasic aspart 30 in well-controlled patients with type 2 diabetes using continuous glucose monitoring"]}]}],"canonical_facts":{"dc:creator":["Margaritidis, Charalampos","Μαργαριτίδης, Χαράλαμπος"],"dc:creator.fathername":["Athanasios"],"dc:date":["2021"],"dc:description":["Aim: To compare in terms of glycemic variability two premixed insulins, Premixed HumanInsulin 30/70 (PHI) and Biphasic Aspart 30 (BiAsp30), using Continuous Glucose Monitoring (CGM)and to estimate the correlation of Glycated Albumin (GA) and Fructosamine (FA) with CGM data.Patients-Data: A total of 36 well-controlled patients with type 2 Diabetes Mellitus (T2DM) underwent7-day CGM with PHI and subsequently with BiAsp30. GA and FA were measured at the first and lastday of each week of CGM. Results: BiAsp30 was associated with lower Average Blood Glucose(ABG) during the 23:00–03:00 period (PHI: 135.08 28.94 mg/dL, BiAsp30: 117.75 21.24 mg/dL,p < 0.001) and the 00:00–06:00 period (PHI: 120.42 23.13 mg/dL, BiAsp30: 111.17 14.74 mg/dL,p = 0.008), as well as with more time below range (<70 mg/dL) (TBR) during the 23:00–03:00 periodin the week (PHI: 3.65 5.93%, BiAsp30: 11.12 16.07%, p = 0.005). PHI was associated withlower ABG before breakfast (PHI: 111.75 23.9 mg/dL, BiAsp30: 128.25 35.9 mg/dL, p = 0.013).There were no differences between the two groups in ABG, Time In Range and Time Below Rangeduring the entire 24-h period for 7 days, p = 0.502, p = 0.534, and p = 0.258 respectively, and inTBR for the 00:00–06:00 period p = 0.253. Total daily insulin requirements were higher for BiAsp30(PHI: 47.92 12.18 IU, BiAsp30: 49.58 14.12 IU, p = 0.001). GA and FA correlated significantlywith ABG (GA: r = 0.512, p = 0.011, FA: r = 0.555, p = 0.005). Conclusions: In well-controlled patientswith T2DM, BiAsp30 is an equally effective alternative to PHI.","ΣΚΟΠΟΣ: Η συγκριτική μελέτη δύο σχημάτων ινσουλινοθεραπείας (μίγμα ανθρώπινης ινσουλίνης 30/70-PIΗ και μίγμα ανάλογου-PAI, και συγκεκριμένα διφασική ινσουλίνη Aspart 30/70-Biasp30) με τη χρήση αισθητήρων γλυκόζης, και εκτίμηση της συσχέτισης της γλυκοζυλιωμένης αιμοσφαιρίνης (HbA1c), της γλυκοζυλιωμένης αλβουμίνης(GA) και της φρουκτοζαμίνης(FA) με τα δεδομένα της συνεχούς καταγραφής(CGM). ΑΣΘΕΝΕΙΣ-ΜΕΘΟΔΟΙ: Μια cross-over μελέτη σε 36 καλά ρυθμισμένα άτομα με Σακχαρώδη Διαβήτη τύπου 2 (ΣΔτ2), οι οποίοι υποβλήθηκαν σε 7ήμερη CGM με το PHI και στη συνέχεια με το Biasp30. ΑΠΟΤΕΛΕΣΜΑΤΑ: Το Biasp30 πέτυχε χαμηλότερη μέση τιμή γλυκόζης (Average Blood Glucose- ABG) για το διάστημα 23:00-03:00 (PHI: 135.08± 28.94mg/dl, Biasp30: 117.75± 21.24 mg/dl, p<0.001) και το διάστημα 00:00-06:00 (PHI: 120.42 ±23.13mg/dl, Biasp30: 111.17± 14.74, p=0.008, περισσότερο χρόνο σε επίπεδα γλυκόζης κάτω από το όριο των 70mg/dl (Time Below Range-TBR) για το διάστημα 23:00-03:00 (PHI: 58.75 ± 99.49min, Biasp30: 179.17 ± 249.30min,p=0.003). Το PHI πέτυχε χαμηλότερη ABG πριν το πρωινό (PHI: 111.75± 23.9 mg/dl, Biasp30: 128.25± 35.9mg/dl, p=0.013). Δεν υπήρξαν διαφορές μεταξύ των δύο ομάδων στην ABG για το συνολικό διάστημα του 24ώρου (PHI: 140.08± 20.71mg/dl, Biasp30:138.08± 17.93mg/dl,p=0.502), στο χρόνο εντός του στόχου (Time In Range -TIR-% του συνολικού χρόνου καταγραφής) (PHI: 75.92± 12.42%, Biasp30:74.17± 15.90%, p=0.534) και στο συνολικό TBR (% of the total CGM time) (PHI: 4.17± 3.55%, Biasp30: 5.5± 3.40%, p=0.063),και στο TBR για το διάστημα 00:00-06:00 period (PHI: 8.45 ± 8.81%, Biasp30: 12.08 ± 16.13%, p=0.253). Οι συνολικές μονάδες ινσουλίνης ήταν περισσότερες με το Biasp30(PHI: 47.92± 12.18 IU, Biasp30:49.58± 14.12 IU, p=0.001). HbA1c, GA and FA εμφάνισαν στατιστικά σημαντική συσχέτιση με την ABG (GA: r=0.512, p=0.011, FA: r=0.555, p=0.005, HbA1c: r=0.642, p=0.001).ΣΥΜΠΕΡΑΣΜΑΤΑ: Σε καλά ρυθμισμένους ασθενείς με ΣΔτ2 τα PIA και αποτελούν ισάξιες επιλογές με τα PHI. Από τους διάφορους δείκτες γλυκαιμικής μεταβλητότητας η HbA1c παρουσιάζει την ισχυρότερη συσχέτιση με την ABG."],"dc:identifier":["10.12681/eadd/49453","http://hdl.handle.net/10442/hedi/49453"],"dc:language":["gre"],"dc:publisher":["Aristotle University Of Thessaloniki (AUTH)","Αριστοτέλειο Πανεπιστήμιο Θεσσαλονίκης (ΑΠΘ)"],"dc:rights":["BY_NC_ND_4_0"],"dc:subject":["Αισθητήρες γλυκόζης","Συνεχής καταγραφή γλυκόζης","Μίγματα ινσουλίνης","Σακχαρώδης Διαβήτης (ΣΔ)","Glucose sensors","Continuous Glucose Monitoring","Premixed insulins","Diabetes mellitus","Κλινική Ιατρική","Ιατρική και Επιστήμες Υγείας","Ενδοκρινολογία, Διαβήτης και Μεταβολισμός","Γενική και Εσωτερική ιατρική","Clinical Medicine","Medical and Health Sciences","Endocrinology, Diabetes and Metabolism","General and Internal Medicine"],"dc:title":["Συγκριτική μελέτη δύο σχημάτων ινσουλινοθεραπείας σε ασθενείς με σακχαρώδη διαβήτη τύπου 2 με την χρήση αισθητήρων γλυκόζης","Comparison of premixed human insulin 30/70 to biphasic aspart 30 in well-controlled patients with type 2 diabetes using continuous glucose monitoring"],"dc:type":["PhD Thesis"]},"updated_at":"2026-11-18T21:40:42Z"}