{"id":{"repo_id":"greece","oai_identifier":"oai:10442/59746"},"canonical_url":"https://search.ndltd.org/etd/greece/oai:10442/59746","repository":{"repo_id":"greece","name":"Greek National Archive of PhD Theses","base_url":"https://phdtheses.ekt.gr/eadd_oai/request"},"display":{"title":"Magnetic resonance imaging of transmembrane water permeability for detection of cell death","abstract":"The apparent exchange rate (AXR) detected by magnetic resonance filter-exchange spectroscopy (FEXSY) and imaging (FEXI) quantifies transmembrane water exchange, which is altered after cell death initiation. Here, FEXSY and FEXI protocols were implemented on a preclinical and clinical MRI system. The AXR is shown as a contrast agent-free early cell death imaging biomarker in vitro and in vivo. A pilot study in patients demonstrates the translatability of AXR measurements to the clinic.","abstract_html":"The apparent exchange rate (AXR) detected by magnetic resonance filter-exchange spectroscopy (FEXSY) and imaging (FEXI) quantifies transmembrane water exchange, which is altered after cell death initiation. Here, FEXSY and FEXI protocols were implemented on a preclinical and clinical MRI system. The AXR is shown as a contrast agent-free early cell death imaging biomarker in vitro and in vivo. A pilot study in patients demonstrates the translatability of AXR measurements to the clinic.","abstract_has_math":false,"creators":["Kaika, Athanasia","Καΐκα, Αθανασία"],"institution":"Institutes outside Greece","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024","date_published":"2024","updated_at":"2026-11-18T22:23:52Z","subjects":["Πυρηνικός μαγνητικός συντονισμός","Μαγνητική τομογραφία","Διαμεμβρανιακή διαπερατότητα νερού","Φαινομενικός συντελεστής ανταλλαγής","Ρυθμός ανταλλαγής νερού","Κυτταρικός θάνατος","NMR","MRI","Transmembrane water permeability","AXR","Water exchange rate","FEXSY","FEXI","Cell death","Φυσική","Φυσικές Επιστήμες","Εφαρμοσμένη φυσική","Ιατρική Βιοτεχνολογία","Ιατρική και Επιστήμες Υγείας","Physical Sciences","Natural Sciences","Applied Physics","Medical Biotechnology","Medical and Health Sciences"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["10.12681/eadd/59746"],"render_values":[{"text":"10.12681/eadd/59746","href":"https://doi.org/10.12681/eadd/59746","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10442/hedi/59746","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/10442/hedi/59746","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://phdtheses.ekt.gr/eadd_oai/request?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3A10442%2F59746","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Kaika, Athanasia","Καΐκα, Αθανασία"]},{"key":"dc:creator.fathername","label":"Dc Creator Fathername","values":["Nikolaos"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2024"]},{"key":"dc:publisher","label":"Institution","values":["Institutes outside Greece","Ιδρύματα Εξωτερικού"]},{"key":"dc:type","label":"Dc Type","values":["PhD Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Πυρηνικός μαγνητικός συντονισμός","Μαγνητική τομογραφία","Διαμεμβρανιακή διαπερατότητα νερού","Φαινομενικός συντελεστής ανταλλαγής","Ρυθμός ανταλλαγής νερού","Κυτταρικός θάνατος","NMR","MRI","Transmembrane water permeability","AXR","Water exchange rate","FEXSY","FEXI","Cell death","Φυσική","Φυσικές Επιστήμες","Εφαρμοσμένη φυσική","Ιατρική Βιοτεχνολογία","Ιατρική και Επιστήμες Υγείας","Physical Sciences","Natural Sciences","Applied Physics","Medical Biotechnology","Medical and Health Sciences"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.12681/eadd/59746","http://hdl.handle.net/10442/hedi/59746"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The apparent exchange rate (AXR) detected by magnetic resonance filter-exchange spectroscopy (FEXSY) and imaging (FEXI) quantifies transmembrane water exchange, which is altered after cell death initiation. Here, FEXSY and FEXI protocols were implemented on a preclinical and clinical MRI system. The AXR is shown as a contrast agent-free early cell death imaging biomarker in vitro and in vivo. A pilot study in patients demonstrates the translatability of AXR measurements to the clinic.","Ο φαινομενικός συντελεστής ανταλλαγής (AXR) που ανιχνεύεται με φασματοσκοπία ανταλλαγής μαγνητικού συντονισμού (FEXSY) και απεικόνιση (FEXI) ποσοτικοποιεί την διαμεμβρανική ανταλλαγή νερού, η οποία μεταβάλλεται μετά την έναρξη του κυτταρικού θανάτου. Σε αυτή την μελέτη, αναπτύχθηκαν πρωτόκολλα FEXSY και FEXI για εφαρμογές σε προκλινικό και κλινικό σύστημα μαγνητικής τομογραφίας. Ο AXR αναδείχτηκε βιοδείκτης απεικόνισης του πρόωρου κυτταρικού θανάτου χωρίς την χρήση σκιαγραφικού παράγοντα in vitro και in vivo. Επιπλέον, μια πιλοτική μελέτη σε ασθενείς αποδεικνύει τη δυνατότητα ένταξης του AXR ως κλινικό βιοδείκτη."]},{"key":"dc:title","label":"Title","values":["Magnetic resonance imaging of transmembrane water permeability for detection of cell death","Απεικόνιση μαγνητικού συντονισμού της διαμεμβρανικής διαπερατότητας του νερού για την ανίχνευση του κυτταρικού θανάτου"]}]}],"canonical_facts":{"dc:creator":["Kaika, Athanasia","Καΐκα, Αθανασία"],"dc:creator.fathername":["Nikolaos"],"dc:date":["2024"],"dc:description":["The apparent exchange rate (AXR) detected by magnetic resonance filter-exchange spectroscopy (FEXSY) and imaging (FEXI) quantifies transmembrane water exchange, which is altered after cell death initiation. Here, FEXSY and FEXI protocols were implemented on a preclinical and clinical MRI system. The AXR is shown as a contrast agent-free early cell death imaging biomarker in vitro and in vivo. A pilot study in patients demonstrates the translatability of AXR measurements to the clinic.","Ο φαινομενικός συντελεστής ανταλλαγής (AXR) που ανιχνεύεται με φασματοσκοπία ανταλλαγής μαγνητικού συντονισμού (FEXSY) και απεικόνιση (FEXI) ποσοτικοποιεί την διαμεμβρανική ανταλλαγή νερού, η οποία μεταβάλλεται μετά την έναρξη του κυτταρικού θανάτου. Σε αυτή την μελέτη, αναπτύχθηκαν πρωτόκολλα FEXSY και FEXI για εφαρμογές σε προκλινικό και κλινικό σύστημα μαγνητικής τομογραφίας. Ο AXR αναδείχτηκε βιοδείκτης απεικόνισης του πρόωρου κυτταρικού θανάτου χωρίς την χρήση σκιαγραφικού παράγοντα in vitro και in vivo. Επιπλέον, μια πιλοτική μελέτη σε ασθενείς αποδεικνύει τη δυνατότητα ένταξης του AXR ως κλινικό βιοδείκτη."],"dc:identifier":["10.12681/eadd/59746","http://hdl.handle.net/10442/hedi/59746"],"dc:language":["eng"],"dc:publisher":["Institutes outside Greece","Ιδρύματα Εξωτερικού"],"dc:subject":["Πυρηνικός μαγνητικός συντονισμός","Μαγνητική τομογραφία","Διαμεμβρανιακή διαπερατότητα νερού","Φαινομενικός συντελεστής ανταλλαγής","Ρυθμός ανταλλαγής νερού","Κυτταρικός θάνατος","NMR","MRI","Transmembrane water permeability","AXR","Water exchange rate","FEXSY","FEXI","Cell death","Φυσική","Φυσικές Επιστήμες","Εφαρμοσμένη φυσική","Ιατρική Βιοτεχνολογία","Ιατρική και Επιστήμες Υγείας","Physical Sciences","Natural Sciences","Applied Physics","Medical Biotechnology","Medical and Health Sciences"],"dc:title":["Magnetic resonance imaging of transmembrane water permeability for detection of cell death","Απεικόνιση μαγνητικού συντονισμού της διαμεμβρανικής διαπερατότητας του νερού για την ανίχνευση του κυτταρικού θανάτου"],"dc:type":["PhD Thesis"]},"updated_at":"2026-11-18T22:23:52Z"}