{"id":{"repo_id":"greece","oai_identifier":"oai:10442/8564"},"canonical_url":"https://search.ndltd.org/etd/greece/oai:10442/8564","repository":{"repo_id":"greece","name":"Greek National Archive of PhD Theses","base_url":"https://phdtheses.ekt.gr/eadd_oai/request"},"display":{"title":"ΣΥΓΚΡΙΤΙΚΗ ΜΕΛΕΤΗ ΤΟΥ ΕΛΕΓΧΟΥ ΤΗΣ ΝΕΟΟΣΤΕΟΓΕΝΕΣΗΣ ΣΕ ΕΠΙΜΗΚΥΝΣΕΙΣ ΜΑΚΡΩΝ ΟΣΤΩΝ - ΜΕ ΤΗΝ ΜΕΘΟΔΟ ILIZAROV - ΜΕ ΑΠΛΗ ΑΚΤΙΝΟΓΡΑΦΙΑ, ΥΠΕΡΗΧΟΥΣ, ΠΟΣΟΤΙΚΗ ΚΑΙ ΤΡΙΣΔΙΑΣΤΑΤΗ ΑΞΟΝΙΚΗ ΤΟΜΟΓΡΑΦΙΑ (QCT - 3DCT)","abstract":"IN 20 PATIENTS WHO UNDERWENT BONE LENGTHENING, BONE DENSITY OF NEWLY FORMED BONE WAS MEASURED WITH QCT SLICES AND THREE DIMENSIONAL RECONSTRUCTION OF IMAGES (3D - CT) WAS PERFORMED AT THE END OF LENGTHENING AND MATURATION PHASE. THE DENSITY OF EVERY SLICE WAS MEASURED WITH RESPECT TO ITS DISTANCE FROM THE CORTICOTOMY BORDER. THUS, WITH COMPARISON OF DENSITIES OF SAME SLICES AT THE END OF BOTH PHASES, THE RHYTHM OF NEW BONE FORMATION WAS STUDIED IN REFERENCE TO TIMEAND SPACE. IN AN EXPERIMENT PERFORMED ON 50 CADAVER TIBIAS, BONE DENSITIES OF QCT SLICES WERE MEASURED THROUGOUT THE WHOLE LENGTH OF TIBIAE. MEAN AND MINIMAL BONE DENSITY VALUES WERE FOUND AND COMPARED TO THOSE OBSERVED IN OUR PATIENTS. IN ANOTHER EXPERIMENT ON 30 CADAVER TIBIAS, BONE DENSITY OF MARKED SLICES WERE MEASURED WITH AND WITHOUT THE ILIZAROV APPARATUS. ARTIFACTS PRODUCEDBY THE PRESENCE OF THE APPARATUS WERE IDENTIFIED IN VARIOUS DISTANCES FROM THE APPARATUS RINGS. IN A THIRD EXPERIMENT WE MEASURED THE IRRADIATION ABSORPTION OF VARIOUS POINTS ON A PLEXYGLASS PHANTOM. OUR RESULTS SHOWED A SMALL DOSE OF IRRADIATION ABSORBED BY THE GONADS, STATISTICALLY INSIGNIFICANT ARTIFACTS FOR SLICES TAKEN>1CM AWAY FROM THE APPARATUS RINGS AND AN EXACT DETERMINATION OF BONE MATURATION. WITH 3D - CT WE OBTAINED AN EXCELLENT ESTIMATION OF THE DISTRIBUTION OF NEW BONE IN SPACE, WHICH LED US TO A SAFER DECISION ON THE APPROPRIATE TIME FOR APPARATUS REMOVAL.","abstract_html":"IN 20 PATIENTS WHO UNDERWENT BONE LENGTHENING, BONE DENSITY OF NEWLY FORMED BONE WAS MEASURED WITH QCT SLICES AND THREE DIMENSIONAL RECONSTRUCTION OF IMAGES (3D - CT) WAS PERFORMED AT THE END OF LENGTHENING AND MATURATION PHASE. THE DENSITY OF EVERY SLICE WAS MEASURED WITH RESPECT TO ITS DISTANCE FROM THE CORTICOTOMY BORDER. THUS, WITH COMPARISON OF DENSITIES OF SAME SLICES AT THE END OF BOTH PHASES, THE RHYTHM OF NEW BONE FORMATION WAS STUDIED IN REFERENCE TO TIMEAND SPACE. IN AN EXPERIMENT PERFORMED ON 50 CADAVER TIBIAS, BONE DENSITIES OF QCT SLICES WERE MEASURED THROUGOUT THE WHOLE LENGTH OF TIBIAE. MEAN AND MINIMAL BONE DENSITY VALUES WERE FOUND AND COMPARED TO THOSE OBSERVED IN OUR PATIENTS. IN ANOTHER EXPERIMENT ON 30 CADAVER TIBIAS, BONE DENSITY OF MARKED SLICES WERE MEASURED WITH AND WITHOUT THE ILIZAROV APPARATUS. ARTIFACTS PRODUCEDBY THE PRESENCE OF THE APPARATUS WERE IDENTIFIED IN VARIOUS DISTANCES FROM THE APPARATUS RINGS. IN A THIRD EXPERIMENT WE MEASURED THE IRRADIATION ABSORPTION OF VARIOUS POINTS ON A PLEXYGLASS PHANTOM. OUR RESULTS SHOWED A SMALL DOSE OF IRRADIATION ABSORBED BY THE GONADS, STATISTICALLY INSIGNIFICANT ARTIFACTS FOR SLICES TAKEN&gt;1CM AWAY FROM THE APPARATUS RINGS AND AN EXACT DETERMINATION OF BONE MATURATION. WITH 3D - CT WE OBTAINED AN EXCELLENT ESTIMATION OF THE DISTRIBUTION OF NEW BONE IN SPACE, WHICH LED US TO A SAFER DECISION ON THE APPROPRIATE TIME FOR APPARATUS REMOVAL.","abstract_has_math":false,"creators":["Salmas, Marios","Σαλμάς, Μάριος"],"institution":"University of Patras","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1997,"date_issued":"1997","date_published":"1997","updated_at":"2026-11-18T20:24:46Z","subjects":["Ακτινογραφίες","ΕΠΙΜΗΚΥΝΣΗ ΟΣΤΩΝ","Οστεογένεση","ΠΟΣΟΤΙΚΗ ΑΞΟΝΙΚΗ ΤΟΜΟΓΡΑΦΙΑ","ΤΡΙΣΔΙΑΣΤΑΤΗ ΑΞΟΝΙΚΗ ΤΟΜΟΓΡΑΦΙΑ","Υπέρηχοι","ΦΛΟΙΟΤΟΜΗ","3D - CT","Bone lenghening","Corticotomy","Ilizarov","Osteogenesis","PLAIN X-RAYS","QCT","Ultrasound","Ιατρική και Επιστήμες Υγείας","Κλινική Ιατρική","Medical and Health Sciences","Clinical Medicine"],"languages":["gre"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["10.12681/eadd/8564"],"render_values":[{"text":"10.12681/eadd/8564","href":"https://doi.org/10.12681/eadd/8564","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10442/hedi/8564","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/10442/hedi/8564","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://phdtheses.ekt.gr/eadd_oai/request?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3A10442%2F8564","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Salmas, Marios","Σαλμάς, Μάριος"]},{"key":"dc:creator.fathername","label":"Dc Creator Fathername","values":["Georgios"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1997"]},{"key":"dc:publisher","label":"Institution","values":["University of Patras","Πανεπιστήμιο Πατρών"]},{"key":"dc:type","label":"Dc Type","values":["PhD Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Ακτινογραφίες","ΕΠΙΜΗΚΥΝΣΗ ΟΣΤΩΝ","Οστεογένεση","ΠΟΣΟΤΙΚΗ ΑΞΟΝΙΚΗ ΤΟΜΟΓΡΑΦΙΑ","ΤΡΙΣΔΙΑΣΤΑΤΗ ΑΞΟΝΙΚΗ ΤΟΜΟΓΡΑΦΙΑ","Υπέρηχοι","ΦΛΟΙΟΤΟΜΗ","3D - CT","Bone lenghening","Corticotomy","Ilizarov","Osteogenesis","PLAIN X-RAYS","QCT","Ultrasound","Ιατρική και Επιστήμες Υγείας","Κλινική Ιατρική","Medical and Health Sciences","Clinical Medicine"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["gre"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.12681/eadd/8564","http://hdl.handle.net/10442/hedi/8564"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["IN 20 PATIENTS WHO UNDERWENT BONE LENGTHENING, BONE DENSITY OF NEWLY FORMED BONE WAS MEASURED WITH QCT SLICES AND THREE DIMENSIONAL RECONSTRUCTION OF IMAGES (3D - CT) WAS PERFORMED AT THE END OF LENGTHENING AND MATURATION PHASE. THE DENSITY OF EVERY SLICE WAS MEASURED WITH RESPECT TO ITS DISTANCE FROM THE CORTICOTOMY BORDER. THUS, WITH COMPARISON OF DENSITIES OF SAME SLICES AT THE END OF BOTH PHASES, THE RHYTHM OF NEW BONE FORMATION WAS STUDIED IN REFERENCE TO TIMEAND SPACE. IN AN EXPERIMENT PERFORMED ON 50 CADAVER TIBIAS, BONE DENSITIES OF QCT SLICES WERE MEASURED THROUGOUT THE WHOLE LENGTH OF TIBIAE. MEAN AND MINIMAL BONE DENSITY VALUES WERE FOUND AND COMPARED TO THOSE OBSERVED IN OUR PATIENTS. IN ANOTHER EXPERIMENT ON 30 CADAVER TIBIAS, BONE DENSITY OF MARKED SLICES WERE MEASURED WITH AND WITHOUT THE ILIZAROV APPARATUS. ARTIFACTS PRODUCEDBY THE PRESENCE OF THE APPARATUS WERE IDENTIFIED IN VARIOUS DISTANCES FROM THE APPARATUS RINGS. IN A THIRD EXPERIMENT WE MEASURED THE IRRADIATION ABSORPTION OF VARIOUS POINTS ON A PLEXYGLASS PHANTOM. OUR RESULTS SHOWED A SMALL DOSE OF IRRADIATION ABSORBED BY THE GONADS, STATISTICALLY INSIGNIFICANT ARTIFACTS FOR SLICES TAKEN>1CM AWAY FROM THE APPARATUS RINGS AND AN EXACT DETERMINATION OF BONE MATURATION. WITH 3D - CT WE OBTAINED AN EXCELLENT ESTIMATION OF THE DISTRIBUTION OF NEW BONE IN SPACE, WHICH LED US TO A SAFER DECISION ON THE APPROPRIATE TIME FOR APPARATUS REMOVAL.","ΣΕ 20 ΑΣΘΕΝΕΙΣ ΟΙ ΟΠΟΙΟΙ ΥΠΟΒΛΗΘΗΚΑΝ ΣΕ ΕΠΙΜΗΚΥΝΣΗ ΟΣΤΟΥ, ΜΕΤΡΗΘΗΚΕ Η ΟΣΤΙΚΗ ΠΥΚΝΟΤΗΤΑ ΤΟΥ ΝΕΟΣΧΗΜΑΤΙΣΘΕΝΤΟΣ ΟΣΤΟΥ ΜΕ QCT ΚΑΙ ΤΡΙΣΔΙΑΣΤΑΤΗ ΑΞΟΝΙΚΗ ΤΟΜΟΓΡΑΦΙΑ ΠΟΥ ΕΓΙΝΑΝ ΣΤΟ ΤΕΛΟΣ ΤΗΣ ΦΑΣΗΣ ΕΠΙΜΗΚΥΝΣΗΣ ΚΑΙ ΩΡΙΜΑΝΣΗΣ. Η ΠΥΚΝΟΤΗΤΑ ΤΗΣ ΚΑΘΕ ΤΟΜΗΣ ΜΕΤΡΗΘΗΚΕ ΣΕ ΣΧΕΣΗ ΜΕ ΤΗΝ ΑΠΟΣΤΑΣΗ ΑΠΟ ΤΑ ΑΚΡΑ ΤΗΣ ΚΟΡΤΙΚΟΤΟΜΗΣ.ΕΤΣΙ ΥΣΤΕΡΑ ΑΠΟ ΣΥΓΚΡΙΣΗ ΤΩΝ ΤΙΜΩΝ ΣΤΟ ΤΕΛΟΣ ΚΑΘΕ ΦΑΣΗΣ ΜΕΛΕΤΗΘΗΚΕ Η ΚΑΤΑΝΟΜΗ ΤΟΥ ΝΕΟΥ ΟΣΤΟΥ ΣΤΟ ΧΩΡΟ ΚΑΙ ΤΟΝ ΧΡΟΝΟ. ΠΕΙΡΑΜΑΤΙΚΗ ΜΕΛΕΤΗ ΣΕ 50 ΠΤΩΜΑΤΙΚΕΣΚΝΗΜΕΣ ΣΤΙΣ ΟΠΟΙΕΣ ΜΕΤΡΗΘΗΚΕ Η ΜΕΣΗ ΟΣΤΙΚΗ ΠΥΚΝΟΤΗΤΑ ΟΛΩΝ ΤΩΝ ΤΟΜΩΝ, ΑΝΕΔΕΙΞΕΤΙΣ ΤΙΜΕΣ ΑΝΑΦΟΡΑΣ, ΜΕ ΤΙΣ ΟΠΟΙΕΣ ΣΥΓΚΡΙΘΗΚΑΝ ΤΑ ΔΕΔΟΜΕΝΑ ΤΗΣ ΚΛΙΝΙΚΗΣ ΜΕΛΕΤΗΣ. ΜΕ ΑΛΛΟ ΠΕΙΡΑΜΑ ΣΕ 30 ΠΤΩΜΑΤΙΚΕΣ ΚΝΗΜΕΣ ΜΕΛΕΤΗΘΗΚΑΝ ΟΙ ΜΕΣΕΣ ΤΙΜΕΣ ΠΥΚΝΟΤΗΤΟΣ ΜΕ ΚΑΙ ΧΩΡΙΣ ΤΗΝ ΠΑΡΟΥΣΙΑ ΤΗΣ ΣΥΣΚΕΥΗΣ ILIZAROV ΚΑΙ ΚΑΤΕΓΡΑΦΗΣΑΝ ΤΑ ΤΕΧΝΗΤΑ ΣΦΑΛΜΑΤΑ ΠΟΥ ΟΦΕΙΛΟΝΤΑΝ ΣΤΗΝ ΠΑΡΟΥΣΙΑ ΤΗΣ ΣΥΣΚΕΥΗΣ. ΣΕ ΤΡΙΤΟ ΠΕΙΡΑΜΑ ΜΕΤΡΗΣΑΜΕ ΤΗΝ ΑΚΤΙΝΟΒΟΛΙΑ ΠΟΥ ΑΠΟΡΡΟΦΑΤΑΙ ΑΠΟ ΤΟΥΣ ΙΣΤΟΥΣ ΑΠΟ ΜΙΑ ΕΞΕΤΑΣΗ QCT. ΤΑ ΑΠΟΤΕΛΕΣΜΑΤΑ ΜΑΣ ΕΔΕΙΞΑΝ ΜΙΚΡΗ ΔΟΣΗ ΑΚΤΙΝΟΒΟΛΙΑΣ ΝΑ ΑΠΟΡΡΟΦΑΤΑΙ ΑΠΟ ΤΙΣ ΓΟΝΑΔΕΣ, ΜΗ ΣΗΜΑΝΤΙΚΑ ΣΤΑΤΙΣΤΙΚΩΣ ΤΕΧΝΗΤΑ ΣΦΑΛΜΑΤΑ ΑΠΟ ΤΗΝ ΠΑΡΟΥΣΙΑ ΤΗΣ ΣΥΣΚΕΥΗΣ ΓΙΑ ΤΟΜΗ ΠΟΥ ΑΠΕΙΧΕ ΑΠΟ ΤΟΝ ΔΑΚΤΥΛΙΟ ΑΠΟΣΤΑΣΗΣ > 1CM ΚΑΙ ΑΚΡΙΒΗ ΚΑΘΟΡΙΣΜΟ ΤΗΣ ΩΡΙΜΑΝΣΗΣ ΤΟΥ ΝΕΟΥ ΟΣΤΟΥ. ΜΕ ΤΗΝ 3D - CT ΕΙΧΑΜΕ ΑΡΙΣΤΗ ΕΚΤΙΜΗΣΗ ΤΗΣ ΚΑΤΑΝΟΜΗΣ ΤΟΥ ΝΕΟΥ ΟΣΤΟΥ ΣΤΟ ΧΩΡΟ, Η ΟΠΟΙΑ ΜΑΣ ΟΔΗΓΗΣΕ ΣΕ ΑΣΦΑΛΕΣΤΕΡΗ ΑΠΟΦΑΣΗ ΓΙΑ ΤΗΝ ΑΦΑΙΡΕΣΗ ΤΗΣ ΣΥΣΚΕΥΗΣ."]},{"key":"dc:title","label":"Title","values":["ΣΥΓΚΡΙΤΙΚΗ ΜΕΛΕΤΗ ΤΟΥ ΕΛΕΓΧΟΥ ΤΗΣ ΝΕΟΟΣΤΕΟΓΕΝΕΣΗΣ ΣΕ ΕΠΙΜΗΚΥΝΣΕΙΣ ΜΑΚΡΩΝ ΟΣΤΩΝ - ΜΕ ΤΗΝ ΜΕΘΟΔΟ ILIZAROV - ΜΕ ΑΠΛΗ ΑΚΤΙΝΟΓΡΑΦΙΑ, ΥΠΕΡΗΧΟΥΣ, ΠΟΣΟΤΙΚΗ ΚΑΙ ΤΡΙΣΔΙΑΣΤΑΤΗ ΑΞΟΝΙΚΗ ΤΟΜΟΓΡΑΦΙΑ (QCT - 3DCT)","STUDY OF OSTEOGENESIS IN LONG BONES LENGTHENING WITH METHOD OF ILIZAROV: COMPARING WITH PLAIN X-RAYS, ULTRASOUND, QUANTITATIVE AND THREE DIMENSIONAL COMPUTED TOMOGRAPHY - (QCT, 3D - CT)"]}]}],"canonical_facts":{"dc:creator":["Salmas, Marios","Σαλμάς, Μάριος"],"dc:creator.fathername":["Georgios"],"dc:date":["1997"],"dc:description":["IN 20 PATIENTS WHO UNDERWENT BONE LENGTHENING, BONE DENSITY OF NEWLY FORMED BONE WAS MEASURED WITH QCT SLICES AND THREE DIMENSIONAL RECONSTRUCTION OF IMAGES (3D - CT) WAS PERFORMED AT THE END OF LENGTHENING AND MATURATION PHASE. THE DENSITY OF EVERY SLICE WAS MEASURED WITH RESPECT TO ITS DISTANCE FROM THE CORTICOTOMY BORDER. THUS, WITH COMPARISON OF DENSITIES OF SAME SLICES AT THE END OF BOTH PHASES, THE RHYTHM OF NEW BONE FORMATION WAS STUDIED IN REFERENCE TO TIMEAND SPACE. IN AN EXPERIMENT PERFORMED ON 50 CADAVER TIBIAS, BONE DENSITIES OF QCT SLICES WERE MEASURED THROUGOUT THE WHOLE LENGTH OF TIBIAE. MEAN AND MINIMAL BONE DENSITY VALUES WERE FOUND AND COMPARED TO THOSE OBSERVED IN OUR PATIENTS. IN ANOTHER EXPERIMENT ON 30 CADAVER TIBIAS, BONE DENSITY OF MARKED SLICES WERE MEASURED WITH AND WITHOUT THE ILIZAROV APPARATUS. ARTIFACTS PRODUCEDBY THE PRESENCE OF THE APPARATUS WERE IDENTIFIED IN VARIOUS DISTANCES FROM THE APPARATUS RINGS. IN A THIRD EXPERIMENT WE MEASURED THE IRRADIATION ABSORPTION OF VARIOUS POINTS ON A PLEXYGLASS PHANTOM. OUR RESULTS SHOWED A SMALL DOSE OF IRRADIATION ABSORBED BY THE GONADS, STATISTICALLY INSIGNIFICANT ARTIFACTS FOR SLICES TAKEN>1CM AWAY FROM THE APPARATUS RINGS AND AN EXACT DETERMINATION OF BONE MATURATION. WITH 3D - CT WE OBTAINED AN EXCELLENT ESTIMATION OF THE DISTRIBUTION OF NEW BONE IN SPACE, WHICH LED US TO A SAFER DECISION ON THE APPROPRIATE TIME FOR APPARATUS REMOVAL.","ΣΕ 20 ΑΣΘΕΝΕΙΣ ΟΙ ΟΠΟΙΟΙ ΥΠΟΒΛΗΘΗΚΑΝ ΣΕ ΕΠΙΜΗΚΥΝΣΗ ΟΣΤΟΥ, ΜΕΤΡΗΘΗΚΕ Η ΟΣΤΙΚΗ ΠΥΚΝΟΤΗΤΑ ΤΟΥ ΝΕΟΣΧΗΜΑΤΙΣΘΕΝΤΟΣ ΟΣΤΟΥ ΜΕ QCT ΚΑΙ ΤΡΙΣΔΙΑΣΤΑΤΗ ΑΞΟΝΙΚΗ ΤΟΜΟΓΡΑΦΙΑ ΠΟΥ ΕΓΙΝΑΝ ΣΤΟ ΤΕΛΟΣ ΤΗΣ ΦΑΣΗΣ ΕΠΙΜΗΚΥΝΣΗΣ ΚΑΙ ΩΡΙΜΑΝΣΗΣ. Η ΠΥΚΝΟΤΗΤΑ ΤΗΣ ΚΑΘΕ ΤΟΜΗΣ ΜΕΤΡΗΘΗΚΕ ΣΕ ΣΧΕΣΗ ΜΕ ΤΗΝ ΑΠΟΣΤΑΣΗ ΑΠΟ ΤΑ ΑΚΡΑ ΤΗΣ ΚΟΡΤΙΚΟΤΟΜΗΣ.ΕΤΣΙ ΥΣΤΕΡΑ ΑΠΟ ΣΥΓΚΡΙΣΗ ΤΩΝ ΤΙΜΩΝ ΣΤΟ ΤΕΛΟΣ ΚΑΘΕ ΦΑΣΗΣ ΜΕΛΕΤΗΘΗΚΕ Η ΚΑΤΑΝΟΜΗ ΤΟΥ ΝΕΟΥ ΟΣΤΟΥ ΣΤΟ ΧΩΡΟ ΚΑΙ ΤΟΝ ΧΡΟΝΟ. ΠΕΙΡΑΜΑΤΙΚΗ ΜΕΛΕΤΗ ΣΕ 50 ΠΤΩΜΑΤΙΚΕΣΚΝΗΜΕΣ ΣΤΙΣ ΟΠΟΙΕΣ ΜΕΤΡΗΘΗΚΕ Η ΜΕΣΗ ΟΣΤΙΚΗ ΠΥΚΝΟΤΗΤΑ ΟΛΩΝ ΤΩΝ ΤΟΜΩΝ, ΑΝΕΔΕΙΞΕΤΙΣ ΤΙΜΕΣ ΑΝΑΦΟΡΑΣ, ΜΕ ΤΙΣ ΟΠΟΙΕΣ ΣΥΓΚΡΙΘΗΚΑΝ ΤΑ ΔΕΔΟΜΕΝΑ ΤΗΣ ΚΛΙΝΙΚΗΣ ΜΕΛΕΤΗΣ. ΜΕ ΑΛΛΟ ΠΕΙΡΑΜΑ ΣΕ 30 ΠΤΩΜΑΤΙΚΕΣ ΚΝΗΜΕΣ ΜΕΛΕΤΗΘΗΚΑΝ ΟΙ ΜΕΣΕΣ ΤΙΜΕΣ ΠΥΚΝΟΤΗΤΟΣ ΜΕ ΚΑΙ ΧΩΡΙΣ ΤΗΝ ΠΑΡΟΥΣΙΑ ΤΗΣ ΣΥΣΚΕΥΗΣ ILIZAROV ΚΑΙ ΚΑΤΕΓΡΑΦΗΣΑΝ ΤΑ ΤΕΧΝΗΤΑ ΣΦΑΛΜΑΤΑ ΠΟΥ ΟΦΕΙΛΟΝΤΑΝ ΣΤΗΝ ΠΑΡΟΥΣΙΑ ΤΗΣ ΣΥΣΚΕΥΗΣ. ΣΕ ΤΡΙΤΟ ΠΕΙΡΑΜΑ ΜΕΤΡΗΣΑΜΕ ΤΗΝ ΑΚΤΙΝΟΒΟΛΙΑ ΠΟΥ ΑΠΟΡΡΟΦΑΤΑΙ ΑΠΟ ΤΟΥΣ ΙΣΤΟΥΣ ΑΠΟ ΜΙΑ ΕΞΕΤΑΣΗ QCT. ΤΑ ΑΠΟΤΕΛΕΣΜΑΤΑ ΜΑΣ ΕΔΕΙΞΑΝ ΜΙΚΡΗ ΔΟΣΗ ΑΚΤΙΝΟΒΟΛΙΑΣ ΝΑ ΑΠΟΡΡΟΦΑΤΑΙ ΑΠΟ ΤΙΣ ΓΟΝΑΔΕΣ, ΜΗ ΣΗΜΑΝΤΙΚΑ ΣΤΑΤΙΣΤΙΚΩΣ ΤΕΧΝΗΤΑ ΣΦΑΛΜΑΤΑ ΑΠΟ ΤΗΝ ΠΑΡΟΥΣΙΑ ΤΗΣ ΣΥΣΚΕΥΗΣ ΓΙΑ ΤΟΜΗ ΠΟΥ ΑΠΕΙΧΕ ΑΠΟ ΤΟΝ ΔΑΚΤΥΛΙΟ ΑΠΟΣΤΑΣΗΣ > 1CM ΚΑΙ ΑΚΡΙΒΗ ΚΑΘΟΡΙΣΜΟ ΤΗΣ ΩΡΙΜΑΝΣΗΣ ΤΟΥ ΝΕΟΥ ΟΣΤΟΥ. ΜΕ ΤΗΝ 3D - CT ΕΙΧΑΜΕ ΑΡΙΣΤΗ ΕΚΤΙΜΗΣΗ ΤΗΣ ΚΑΤΑΝΟΜΗΣ ΤΟΥ ΝΕΟΥ ΟΣΤΟΥ ΣΤΟ ΧΩΡΟ, Η ΟΠΟΙΑ ΜΑΣ ΟΔΗΓΗΣΕ ΣΕ ΑΣΦΑΛΕΣΤΕΡΗ ΑΠΟΦΑΣΗ ΓΙΑ ΤΗΝ ΑΦΑΙΡΕΣΗ ΤΗΣ ΣΥΣΚΕΥΗΣ."],"dc:identifier":["10.12681/eadd/8564","http://hdl.handle.net/10442/hedi/8564"],"dc:language":["gre"],"dc:publisher":["University of Patras","Πανεπιστήμιο Πατρών"],"dc:subject":["Ακτινογραφίες","ΕΠΙΜΗΚΥΝΣΗ ΟΣΤΩΝ","Οστεογένεση","ΠΟΣΟΤΙΚΗ ΑΞΟΝΙΚΗ ΤΟΜΟΓΡΑΦΙΑ","ΤΡΙΣΔΙΑΣΤΑΤΗ ΑΞΟΝΙΚΗ ΤΟΜΟΓΡΑΦΙΑ","Υπέρηχοι","ΦΛΟΙΟΤΟΜΗ","3D - CT","Bone lenghening","Corticotomy","Ilizarov","Osteogenesis","PLAIN X-RAYS","QCT","Ultrasound","Ιατρική και Επιστήμες Υγείας","Κλινική Ιατρική","Medical and Health Sciences","Clinical Medicine"],"dc:title":["ΣΥΓΚΡΙΤΙΚΗ ΜΕΛΕΤΗ ΤΟΥ ΕΛΕΓΧΟΥ ΤΗΣ ΝΕΟΟΣΤΕΟΓΕΝΕΣΗΣ ΣΕ ΕΠΙΜΗΚΥΝΣΕΙΣ ΜΑΚΡΩΝ ΟΣΤΩΝ - ΜΕ ΤΗΝ ΜΕΘΟΔΟ ILIZAROV - ΜΕ ΑΠΛΗ ΑΚΤΙΝΟΓΡΑΦΙΑ, ΥΠΕΡΗΧΟΥΣ, ΠΟΣΟΤΙΚΗ ΚΑΙ ΤΡΙΣΔΙΑΣΤΑΤΗ ΑΞΟΝΙΚΗ ΤΟΜΟΓΡΑΦΙΑ (QCT - 3DCT)","STUDY OF OSTEOGENESIS IN LONG BONES LENGTHENING WITH METHOD OF ILIZAROV: COMPARING WITH PLAIN X-RAYS, ULTRASOUND, QUANTITATIVE AND THREE DIMENSIONAL COMPUTED TOMOGRAPHY - (QCT, 3D - CT)"],"dc:type":["PhD Thesis"]},"updated_at":"2026-11-18T20:24:46Z"}