{"id":{"repo_id":"gsu","oai_identifier":"oai:digitalcommons.georgiasouthern.edu:etd-2508"},"canonical_url":"https://search.ndltd.org/etd/gsu/oai:digitalcommons.georgiasouthern.edu:etd-2508","repository":{"repo_id":"gsu","name":"Georgia Southern University","base_url":"https://digitalcommons.georgiasouthern.edu/do/oai/"},"display":{"title":"Assessment of optimized electrode configuration in Electrical Impedance Myography study using genetic algorithm via Finite Element Model","abstract":"Electrical Impedance Myography (EIM) is a neurophysiologic technique in which high- frequency, low-intensity electrical current is applied via surface electrodes over a muscle or muscle group of interest and the resulting electrical parameters (resistance, reactance and phase) are analyzed to isolate diseased muscles from healthy ones. Beside muscle properties, some other anatomic and non-anatomic factors like muscle shape, subcutaneous fat (SF) thickness, inter-electrode distance, etc. also impact the major EIM parameters and thus affect the EIM analysis outcomes. The purpose of this study is to explore the effects of variation in some of these factors impose on EIM parameters and propose an optimum electrode configuration which is least affected by these anatomic and non-anatomic factors without compromising EIM’s ability to detect muscle conditions. In this study, genetic algorithm was applied as an optimization tool in order to find out an optimized electrode setup, which is less prone to these factors other than muscle properties. The results obtained suggest a particular arrangement of electrodes and minimization of electrode surface area to its practical limit, can overcome the effect of undesired factors on EIM parameters to a larger extent.","abstract_html":"Electrical Impedance Myography (EIM) is a neurophysiologic technique in which high- frequency, low-intensity electrical current is applied via surface electrodes over a muscle or muscle group of interest and the resulting electrical parameters (resistance, reactance and phase) are analyzed to isolate diseased muscles from healthy ones. Beside muscle properties, some other anatomic and non-anatomic factors like muscle shape, subcutaneous fat (SF) thickness, inter-electrode distance, etc. also impact the major EIM parameters and thus affect the EIM analysis outcomes. The purpose of this study is to explore the effects of variation in some of these factors impose on EIM parameters and propose an optimum electrode configuration which is least affected by these anatomic and non-anatomic factors without compromising EIM’s ability to detect muscle conditions. In this study, genetic algorithm was applied as an optimization tool in order to find out an optimized electrode setup, which is less prone to these factors other than muscle properties. The results obtained suggest a particular arrangement of electrodes and minimization of electrode surface area to its practical limit, can overcome the effect of undesired factors on EIM parameters to a larger extent.","abstract_has_math":false,"creators":["Baidya, Somen"],"institution":null,"degree_name":"Master of Science in Applied Engineering (M.S.A.E.)","degree_level":"Thesis (open access)","degree_discipline":"Department of Electrical Engineering","degree_department":null,"school":null,"contributors":["Danda Rawat","Rocio Alba-Flores"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:54:33Z","subjects":["EIM","Optimized Electrode Configuration","FEM","Genetic Algorithm","Biomedical","Biomedical Devices and Instrumentation"],"languages":[],"rights":[],"rights_urls":["http://creativecommons.org/licenses/by/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.georgiasouthern.edu/etd/1390","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.georgiasouthern.edu/etd/1390","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.georgiasouthern.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.georgiasouthern.edu%3Aetd-2508","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Danda Rawat","Rocio Alba-Flores"]},{"key":"dc:creator","label":"Author","values":["Baidya, Somen"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2016-04-15T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2016-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Department of Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis (open access)"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Applied Engineering (M.S.A.E.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["EIM","Optimized Electrode Configuration","FEM","Genetic Algorithm","Biomedical","Biomedical Devices and Instrumentation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights.license","label":"Dc Rights License","values":["http://creativecommons.org/licenses/by/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.georgiasouthern.edu/etd/1390"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Electrical Impedance Myography (EIM) is a neurophysiologic technique in which high- frequency, low-intensity electrical current is applied via surface electrodes over a muscle or muscle group of interest and the resulting electrical parameters (resistance, reactance and phase) are analyzed to isolate diseased muscles from healthy ones. Beside muscle properties, some other anatomic and non-anatomic factors like muscle shape, subcutaneous fat (SF) thickness, inter-electrode distance, etc. also impact the major EIM parameters and thus affect the EIM analysis outcomes. The purpose of this study is to explore the effects of variation in some of these factors impose on EIM parameters and propose an optimum electrode configuration which is least affected by these anatomic and non-anatomic factors without compromising EIM’s ability to detect muscle conditions. In this study, genetic algorithm was applied as an optimization tool in order to find out an optimized electrode setup, which is less prone to these factors other than muscle properties. The results obtained suggest a particular arrangement of electrodes and minimization of electrode surface area to its practical limit, can overcome the effect of undesired factors on EIM parameters to a larger extent."]},{"key":"dc:title","label":"Title","values":["Assessment of optimized electrode configuration in Electrical Impedance Myography study using genetic algorithm via Finite Element Model"]}]}],"canonical_facts":{"dc:contributor":["Danda Rawat","Rocio Alba-Flores"],"dc:creator":["Baidya, Somen"],"dc:date.available":["2016-04-15T07:00:00Z"],"dc:date.created":["2016-01-01T08:00:00Z"],"dc:description.abstract":["Electrical Impedance Myography (EIM) is a neurophysiologic technique in which high- frequency, low-intensity electrical current is applied via surface electrodes over a muscle or muscle group of interest and the resulting electrical parameters (resistance, reactance and phase) are analyzed to isolate diseased muscles from healthy ones. Beside muscle properties, some other anatomic and non-anatomic factors like muscle shape, subcutaneous fat (SF) thickness, inter-electrode distance, etc. also impact the major EIM parameters and thus affect the EIM analysis outcomes. The purpose of this study is to explore the effects of variation in some of these factors impose on EIM parameters and propose an optimum electrode configuration which is least affected by these anatomic and non-anatomic factors without compromising EIM’s ability to detect muscle conditions. In this study, genetic algorithm was applied as an optimization tool in order to find out an optimized electrode setup, which is less prone to these factors other than muscle properties. The results obtained suggest a particular arrangement of electrodes and minimization of electrode surface area to its practical limit, can overcome the effect of undesired factors on EIM parameters to a larger extent."],"dc:identifier":["https://digitalcommons.georgiasouthern.edu/etd/1390"],"dc:rights.license":["http://creativecommons.org/licenses/by/4.0/"],"dc:subject":["EIM","Optimized Electrode Configuration","FEM","Genetic Algorithm","Biomedical","Biomedical Devices and Instrumentation"],"dc:title":["Assessment of optimized electrode configuration in Electrical Impedance Myography study using genetic algorithm via Finite Element Model"],"thesis:degree_discipline":["Department of Electrical Engineering"],"thesis:degree_level":["Thesis (open access)"],"thesis:degree_name":["Master of Science in Applied Engineering (M.S.A.E.)"]},"updated_at":"2026-11-19T07:54:33Z"}