{"id":{"repo_id":"gsu","oai_identifier":"oai:digitalcommons.georgiasouthern.edu:etd-2954"},"canonical_url":"https://search.ndltd.org/etd/gsu/oai:digitalcommons.georgiasouthern.edu:etd-2954","repository":{"repo_id":"gsu","name":"Georgia Southern University","base_url":"https://digitalcommons.georgiasouthern.edu/do/oai/"},"display":{"title":"Active Thermal Management of Electronic Devices Using Fractal Extended Surfaces","abstract":"In the present work, the active thermal management of electronic devices using fractal extended surfaces is experimentally investigated. The thermal performance of extended surfaces inspired by the first four fractal iterations of the Sierpinski carpet fractal pattern in a forced convection environment was quantified based on fin effectiveness, fin efficiency, and fin effectiveness per unit mass. The fins were experimentally examined in a thermal testing tunnel with a range of velocities (0.5m/s, 1m/s, 2m/s, and 4m/s). When compared to a solid rectangular fin, without perforations, of equal height, width, and thickness (2in x 2in x 1/16in), the Sierpinski carpet fractal pattern of the fourth iteration was found to be 4.26% more effective at dissipating heat by convection. It was also found that the 2in fins were 2.91 % more effective than 4in fins of the Sierpinski carpet fractal pattern.","abstract_html":"In the present work, the active thermal management of electronic devices using fractal extended surfaces is experimentally investigated. The thermal performance of extended surfaces inspired by the first four fractal iterations of the Sierpinski carpet fractal pattern in a forced convection environment was quantified based on fin effectiveness, fin efficiency, and fin effectiveness per unit mass. The fins were experimentally examined in a thermal testing tunnel with a range of velocities (0.5m/s, 1m/s, 2m/s, and 4m/s). When compared to a solid rectangular fin, without perforations, of equal height, width, and thickness (2in x 2in x 1/16in), the Sierpinski carpet fractal pattern of the fourth iteration was found to be 4.26% more effective at dissipating heat by convection. It was also found that the 2in fins were 2.91 % more effective than 4in fins of the Sierpinski carpet fractal pattern.","abstract_has_math":false,"creators":["Wolfe, Tiesha M"],"institution":null,"degree_name":"Master of Science in Applied Engineering (M.S.A.E.)","degree_level":"Thesis (restricted to Georgia Southern)","degree_discipline":"Department of Mechanical Engineering","degree_department":null,"school":null,"contributors":["Brian L Vlcek","Marcel Ilie"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:56:03Z","subjects":["Thesis","College of Graduate Studies","Graduate Degree","Georgia Southern University","Sierpinski Carpet Fractal Fin","Forced Convection","Fin Efficiency","Fin Effectiveness","Fin Effectiveness Per Unit Mass","Applied Mechanics","Electrical and Electronics","Energy Systems","Heat Transfer, Combustion"],"languages":[],"rights":[],"rights_urls":["http://creativecommons.org/licenses/by/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.georgiasouthern.edu/etd/1824","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.georgiasouthern.edu/etd/1824","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.georgiasouthern.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.georgiasouthern.edu%3Aetd-2954","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Brian L Vlcek","Marcel Ilie"]},{"key":"dc:creator","label":"Author","values":["Wolfe, Tiesha M"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2020-08-30T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2018-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Department of Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis (restricted to Georgia Southern)"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Applied Engineering (M.S.A.E.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Thesis","College of Graduate Studies","Graduate Degree","Georgia Southern University","Sierpinski Carpet Fractal Fin","Forced Convection","Fin Efficiency","Fin Effectiveness","Fin Effectiveness Per Unit Mass","Applied Mechanics","Electrical and Electronics","Energy Systems","Heat Transfer, Combustion"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights.license","label":"Dc Rights License","values":["http://creativecommons.org/licenses/by/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.georgiasouthern.edu/etd/1824"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In the present work, the active thermal management of electronic devices using fractal extended surfaces is experimentally investigated. The thermal performance of extended surfaces inspired by the first four fractal iterations of the Sierpinski carpet fractal pattern in a forced convection environment was quantified based on fin effectiveness, fin efficiency, and fin effectiveness per unit mass. The fins were experimentally examined in a thermal testing tunnel with a range of velocities (0.5m/s, 1m/s, 2m/s, and 4m/s). When compared to a solid rectangular fin, without perforations, of equal height, width, and thickness (2in x 2in x 1/16in), the Sierpinski carpet fractal pattern of the fourth iteration was found to be 4.26% more effective at dissipating heat by convection. It was also found that the 2in fins were 2.91 % more effective than 4in fins of the Sierpinski carpet fractal pattern."]},{"key":"dc:source","label":"Dc Source","values":["Wolfe, T., and Calamas, D., 2018, \"Active Thermal Management of Electronic Devices Using Fractal Extended Surfaces,\" J Heat Transfer"]},{"key":"dc:title","label":"Title","values":["Active Thermal Management of Electronic Devices Using Fractal Extended Surfaces"]}]}],"canonical_facts":{"dc:contributor":["Brian L Vlcek","Marcel Ilie"],"dc:creator":["Wolfe, Tiesha M"],"dc:date.available":["2020-08-30T07:00:00Z"],"dc:date.created":["2018-01-01T08:00:00Z"],"dc:description.abstract":["In the present work, the active thermal management of electronic devices using fractal extended surfaces is experimentally investigated. The thermal performance of extended surfaces inspired by the first four fractal iterations of the Sierpinski carpet fractal pattern in a forced convection environment was quantified based on fin effectiveness, fin efficiency, and fin effectiveness per unit mass. The fins were experimentally examined in a thermal testing tunnel with a range of velocities (0.5m/s, 1m/s, 2m/s, and 4m/s). When compared to a solid rectangular fin, without perforations, of equal height, width, and thickness (2in x 2in x 1/16in), the Sierpinski carpet fractal pattern of the fourth iteration was found to be 4.26% more effective at dissipating heat by convection. It was also found that the 2in fins were 2.91 % more effective than 4in fins of the Sierpinski carpet fractal pattern."],"dc:identifier":["https://digitalcommons.georgiasouthern.edu/etd/1824"],"dc:rights.license":["http://creativecommons.org/licenses/by/4.0/"],"dc:source":["Wolfe, T., and Calamas, D., 2018, \"Active Thermal Management of Electronic Devices Using Fractal Extended Surfaces,\" J Heat Transfer"],"dc:subject":["Thesis","College of Graduate Studies","Graduate Degree","Georgia Southern University","Sierpinski Carpet Fractal Fin","Forced Convection","Fin Efficiency","Fin Effectiveness","Fin Effectiveness Per Unit Mass","Applied Mechanics","Electrical and Electronics","Energy Systems","Heat Transfer, Combustion"],"dc:title":["Active Thermal Management of Electronic Devices Using Fractal Extended Surfaces"],"thesis:degree_discipline":["Department of Mechanical Engineering"],"thesis:degree_level":["Thesis (restricted to Georgia Southern)"],"thesis:degree_name":["Master of Science in Applied Engineering (M.S.A.E.)"]},"updated_at":"2026-11-19T07:56:03Z"}