{"id":{"repo_id":"gsu","oai_identifier":"oai:digitalcommons.georgiasouthern.edu:etd-3959"},"canonical_url":"https://search.ndltd.org/etd/gsu/oai:digitalcommons.georgiasouthern.edu:etd-3959","repository":{"repo_id":"gsu","name":"Georgia Southern University","base_url":"https://digitalcommons.georgiasouthern.edu/do/oai/"},"display":{"title":"Optimization of Filter Bank Canonical Correlation Analysis for Ssvep Based Brain Computer Interface","abstract":"Sinusoidal steady state visually evoked potential signals, or SSVEP signals, are a type of brain signal generated through the user’s prolonged exposure to flickering visual stimuli. The canonical correlation analysis(CCA) method is a means of classifying this type of signal by comparing the frequency components of the recorded SSVEP signal to a generated reference signal. This method can be further improved through the use of a filter bank to divide the signal into multiple sub bands before performing analysis and combining the results to determine the frequency classification. The experiment performed in this paper tested five overall parameters to determine which settings would optimize performance for four frequency classifications at 8 Hz, 9 Hz, 10 Hz, and 11 Hz. The parameters tested included: number of reference harmonics, weights a and b, number of sub bands in the filter bank, and the stopband frequencies of the filter bank designs. The highest overall classification accuracy of 98.69 percent was found under four reference harmonics in a filter bank comprised of equally spaced start and stop bands, with four filtered sub bands, and a weight combination of �� = 2, �� = 0.75.","abstract_html":"Sinusoidal steady state visually evoked potential signals, or SSVEP signals, are a type of brain signal generated through the user’s prolonged exposure to flickering visual stimuli. The canonical correlation analysis(CCA) method is a means of classifying this type of signal by comparing the frequency components of the recorded SSVEP signal to a generated reference signal. This method can be further improved through the use of a filter bank to divide the signal into multiple sub bands before performing analysis and combining the results to determine the frequency classification. The experiment performed in this paper tested five overall parameters to determine which settings would optimize performance for four frequency classifications at 8 Hz, 9 Hz, 10 Hz, and 11 Hz. The parameters tested included: number of reference harmonics, weights a and b, number of sub bands in the filter bank, and the stopband frequencies of the filter bank designs. The highest overall classification accuracy of 98.69 percent was found under four reference harmonics in a filter bank comprised of equally spaced start and stop bands, with four filtered sub bands, and a weight combination of �� = 2, �� = 0.75.","abstract_has_math":false,"creators":["Ferrara, Nicholas"],"institution":null,"degree_name":"Master of Science, Electrical Engineering","degree_level":"Thesis (restricted to Georgia Southern)","degree_discipline":"Department of Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":["Dr. Mohammad Ahad","Dr. Fernando Rios"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:56:48Z","subjects":["Brain Computer Interface(BCI)","canonical correlation analysis(CCA)","electroencephalogram(EEG)","filter bank","harmonics","steady state visually evoked potential(SSVEP)","Biomedical","Signal Processing"],"languages":[],"rights":[],"rights_urls":["http://creativecommons.org/licenses/by/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.georgiasouthern.edu/etd/2784","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.georgiasouthern.edu/etd/2784","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.georgiasouthern.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.georgiasouthern.edu%3Aetd-3959","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Dr. Mohammad Ahad","Dr. Fernando Rios"]},{"key":"dc:creator","label":"Author","values":["Ferrara, Nicholas"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2024-04-11T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2024-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Department of Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis (restricted to Georgia Southern)"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science, Electrical Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Brain Computer Interface(BCI)","canonical correlation analysis(CCA)","electroencephalogram(EEG)","filter bank","harmonics","steady state visually evoked potential(SSVEP)","Biomedical","Signal Processing"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights.license","label":"Dc Rights License","values":["http://creativecommons.org/licenses/by/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.georgiasouthern.edu/etd/2784"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Sinusoidal steady state visually evoked potential signals, or SSVEP signals, are a type of brain signal generated through the user’s prolonged exposure to flickering visual stimuli. The canonical correlation analysis(CCA) method is a means of classifying this type of signal by comparing the frequency components of the recorded SSVEP signal to a generated reference signal. This method can be further improved through the use of a filter bank to divide the signal into multiple sub bands before performing analysis and combining the results to determine the frequency classification. The experiment performed in this paper tested five overall parameters to determine which settings would optimize performance for four frequency classifications at 8 Hz, 9 Hz, 10 Hz, and 11 Hz. The parameters tested included: number of reference harmonics, weights a and b, number of sub bands in the filter bank, and the stopband frequencies of the filter bank designs. The highest overall classification accuracy of 98.69 percent was found under four reference harmonics in a filter bank comprised of equally spaced start and stop bands, with four filtered sub bands, and a weight combination of �� = 2, �� = 0.75."]},{"key":"dc:title","label":"Title","values":["Optimization of Filter Bank Canonical Correlation Analysis for Ssvep Based Brain Computer Interface"]}]}],"canonical_facts":{"dc:contributor":["Dr. Mohammad Ahad","Dr. Fernando Rios"],"dc:creator":["Ferrara, Nicholas"],"dc:date.available":["2024-04-11T07:00:00Z"],"dc:date.created":["2024-01-01T08:00:00Z"],"dc:description.abstract":["Sinusoidal steady state visually evoked potential signals, or SSVEP signals, are a type of brain signal generated through the user’s prolonged exposure to flickering visual stimuli. The canonical correlation analysis(CCA) method is a means of classifying this type of signal by comparing the frequency components of the recorded SSVEP signal to a generated reference signal. This method can be further improved through the use of a filter bank to divide the signal into multiple sub bands before performing analysis and combining the results to determine the frequency classification. The experiment performed in this paper tested five overall parameters to determine which settings would optimize performance for four frequency classifications at 8 Hz, 9 Hz, 10 Hz, and 11 Hz. The parameters tested included: number of reference harmonics, weights a and b, number of sub bands in the filter bank, and the stopband frequencies of the filter bank designs. The highest overall classification accuracy of 98.69 percent was found under four reference harmonics in a filter bank comprised of equally spaced start and stop bands, with four filtered sub bands, and a weight combination of �� = 2, �� = 0.75."],"dc:identifier":["https://digitalcommons.georgiasouthern.edu/etd/2784"],"dc:rights.license":["http://creativecommons.org/licenses/by/4.0/"],"dc:subject":["Brain Computer Interface(BCI)","canonical correlation analysis(CCA)","electroencephalogram(EEG)","filter bank","harmonics","steady state visually evoked potential(SSVEP)","Biomedical","Signal Processing"],"dc:title":["Optimization of Filter Bank Canonical Correlation Analysis for Ssvep Based Brain Computer Interface"],"thesis:degree_discipline":["Department of Electrical and Computer Engineering"],"thesis:degree_level":["Thesis (restricted to Georgia Southern)"],"thesis:degree_name":["Master of Science, Electrical Engineering"]},"updated_at":"2026-11-19T07:56:48Z"}