{"id":{"repo_id":"gsu","oai_identifier":"oai:digitalcommons.georgiasouthern.edu:etd-4019"},"canonical_url":"https://search.ndltd.org/etd/gsu/oai:digitalcommons.georgiasouthern.edu:etd-4019","repository":{"repo_id":"gsu","name":"Georgia Southern University","base_url":"https://digitalcommons.georgiasouthern.edu/do/oai/"},"display":{"title":"Feasibility of Pile Driving Analyzer for Pile On Rock","abstract":"The purpose of the field verification of piles is to check whether piles can withstand design load. Two commonly used methods are high strain dynamic piles and static load testing. Static load testing is very time-consuming, requires heavy deadloads and much space, and doesn’t have stress monitoring advantages in piles. High strain dynamic has been employed as an alternative in this regard. Pile dynamic analyzer (PDA) is a device which is used during dynamic testing to analyze the measurements from the test. PDA calculates the geotechnical or structural resistance by using wave mechanics algorithm installed in it. Total driving resistance (or geotechnical resistance) consists of dynamic and static resistance. In PDA, the pile capacity is considered as static resistance which is calculated using Case formula. In this formula, a Case damping factor which represents ground condition needs to be selected carefully since it affects the estimation of maximum pile capacity (RMX). It was found that 0.9 of Case damping factor was used in the reviewed projects with PDA. This is believed to be irrelevant to the ground conditions. Therefore, the estimated ultimate pile capacity (RMX) could be questionable. However, this issue is not supposed to be critical as the final estimation of the pile capacity is estimated by the result of CAPWAP analysis. It has not been confirmed whether the Case damping factor estimated by CAPWAP represents the ground conditions well, especially for rock. Hence, the Case damping factor from CAPWAP still needs to be verified, preferably by static load test. However, it is expected to be very uneconomical for rock, thus alternative methods are recommended for investigation. The CAPWAP damping factors grouped by Banks and Cobb Counties show a good trend against blows per inch in each group. However, it still needs to be interpreted carefully as the other factors affect the penetration of a pile.","abstract_html":"The purpose of the field verification of piles is to check whether piles can withstand design load. Two commonly used methods are high strain dynamic piles and static load testing. Static load testing is very time-consuming, requires heavy deadloads and much space, and doesn’t have stress monitoring advantages in piles. High strain dynamic has been employed as an alternative in this regard. Pile dynamic analyzer (PDA) is a device which is used during dynamic testing to analyze the measurements from the test. PDA calculates the geotechnical or structural resistance by using wave mechanics algorithm installed in it. Total driving resistance (or geotechnical resistance) consists of dynamic and static resistance. In PDA, the pile capacity is considered as static resistance which is calculated using Case formula. In this formula, a Case damping factor which represents ground condition needs to be selected carefully since it affects the estimation of maximum pile capacity (RMX). It was found that 0.9 of Case damping factor was used in the reviewed projects with PDA. This is believed to be irrelevant to the ground conditions. Therefore, the estimated ultimate pile capacity (RMX) could be questionable. However, this issue is not supposed to be critical as the final estimation of the pile capacity is estimated by the result of CAPWAP analysis. It has not been confirmed whether the Case damping factor estimated by CAPWAP represents the ground conditions well, especially for rock. Hence, the Case damping factor from CAPWAP still needs to be verified, preferably by static load test. However, it is expected to be very uneconomical for rock, thus alternative methods are recommended for investigation. The CAPWAP damping factors grouped by Banks and Cobb Counties show a good trend against blows per inch in each group. However, it still needs to be interpreted carefully as the other factors affect the penetration of a pile.","abstract_has_math":false,"creators":["Ahmed, Tanvir"],"institution":null,"degree_name":"Master of Science, Civil Engineering","degree_level":"Thesis (open access)","degree_discipline":"Department of Civil Engineering and Construction","degree_department":null,"school":null,"contributors":["Gustavo Maldonado","Xiaoming Yang"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:55:41Z","subjects":["Wave Mechanics","Pile Driving Analyzer","Hard Rock","Weak Rock","Static Load Test","Dynamic Testing","Geotechnical Engineering"],"languages":[],"rights":[],"rights_urls":["http://creativecommons.org/licenses/by/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.georgiasouthern.edu/etd/2779","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.georgiasouthern.edu/etd/2779","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.georgiasouthern.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.georgiasouthern.edu%3Aetd-4019","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Gustavo Maldonado","Xiaoming Yang"]},{"key":"dc:creator","label":"Author","values":["Ahmed, Tanvir"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2024-04-19T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2024-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Department of Civil Engineering and Construction"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis (open access)"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science, Civil Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Wave Mechanics","Pile Driving Analyzer","Hard Rock","Weak Rock","Static Load Test","Dynamic Testing","Geotechnical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights.license","label":"Dc Rights License","values":["http://creativecommons.org/licenses/by/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.georgiasouthern.edu/etd/2779"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The purpose of the field verification of piles is to check whether piles can withstand design load. Two commonly used methods are high strain dynamic piles and static load testing. Static load testing is very time-consuming, requires heavy deadloads and much space, and doesn’t have stress monitoring advantages in piles. High strain dynamic has been employed as an alternative in this regard. Pile dynamic analyzer (PDA) is a device which is used during dynamic testing to analyze the measurements from the test. PDA calculates the geotechnical or structural resistance by using wave mechanics algorithm installed in it. Total driving resistance (or geotechnical resistance) consists of dynamic and static resistance. In PDA, the pile capacity is considered as static resistance which is calculated using Case formula. In this formula, a Case damping factor which represents ground condition needs to be selected carefully since it affects the estimation of maximum pile capacity (RMX). It was found that 0.9 of Case damping factor was used in the reviewed projects with PDA. This is believed to be irrelevant to the ground conditions. Therefore, the estimated ultimate pile capacity (RMX) could be questionable. However, this issue is not supposed to be critical as the final estimation of the pile capacity is estimated by the result of CAPWAP analysis. It has not been confirmed whether the Case damping factor estimated by CAPWAP represents the ground conditions well, especially for rock. Hence, the Case damping factor from CAPWAP still needs to be verified, preferably by static load test. However, it is expected to be very uneconomical for rock, thus alternative methods are recommended for investigation. The CAPWAP damping factors grouped by Banks and Cobb Counties show a good trend against blows per inch in each group. However, it still needs to be interpreted carefully as the other factors affect the penetration of a pile."]},{"key":"dc:title","label":"Title","values":["Feasibility of Pile Driving Analyzer for Pile On Rock"]}]}],"canonical_facts":{"dc:contributor":["Gustavo Maldonado","Xiaoming Yang"],"dc:creator":["Ahmed, Tanvir"],"dc:date.available":["2024-04-19T07:00:00Z"],"dc:date.created":["2024-01-01T08:00:00Z"],"dc:description.abstract":["The purpose of the field verification of piles is to check whether piles can withstand design load. Two commonly used methods are high strain dynamic piles and static load testing. Static load testing is very time-consuming, requires heavy deadloads and much space, and doesn’t have stress monitoring advantages in piles. High strain dynamic has been employed as an alternative in this regard. Pile dynamic analyzer (PDA) is a device which is used during dynamic testing to analyze the measurements from the test. PDA calculates the geotechnical or structural resistance by using wave mechanics algorithm installed in it. Total driving resistance (or geotechnical resistance) consists of dynamic and static resistance. In PDA, the pile capacity is considered as static resistance which is calculated using Case formula. In this formula, a Case damping factor which represents ground condition needs to be selected carefully since it affects the estimation of maximum pile capacity (RMX). It was found that 0.9 of Case damping factor was used in the reviewed projects with PDA. This is believed to be irrelevant to the ground conditions. Therefore, the estimated ultimate pile capacity (RMX) could be questionable. However, this issue is not supposed to be critical as the final estimation of the pile capacity is estimated by the result of CAPWAP analysis. It has not been confirmed whether the Case damping factor estimated by CAPWAP represents the ground conditions well, especially for rock. Hence, the Case damping factor from CAPWAP still needs to be verified, preferably by static load test. However, it is expected to be very uneconomical for rock, thus alternative methods are recommended for investigation. The CAPWAP damping factors grouped by Banks and Cobb Counties show a good trend against blows per inch in each group. However, it still needs to be interpreted carefully as the other factors affect the penetration of a pile."],"dc:identifier":["https://digitalcommons.georgiasouthern.edu/etd/2779"],"dc:rights.license":["http://creativecommons.org/licenses/by/4.0/"],"dc:subject":["Wave Mechanics","Pile Driving Analyzer","Hard Rock","Weak Rock","Static Load Test","Dynamic Testing","Geotechnical Engineering"],"dc:title":["Feasibility of Pile Driving Analyzer for Pile On Rock"],"thesis:degree_discipline":["Department of Civil Engineering and Construction"],"thesis:degree_level":["Thesis (open access)"],"thesis:degree_name":["Master of Science, Civil Engineering"]},"updated_at":"2026-11-19T07:55:41Z"}