{"id":{"repo_id":"gsu","oai_identifier":"oai:digitalcommons.georgiasouthern.edu:etd-4217"},"canonical_url":"https://search.ndltd.org/etd/gsu/oai:digitalcommons.georgiasouthern.edu:etd-4217","repository":{"repo_id":"gsu","name":"Georgia Southern University","base_url":"https://digitalcommons.georgiasouthern.edu/do/oai/"},"display":{"title":"Impact of Y-Mixer Geometry and Flow Rate Modulation on Chemical Gradient Generators in Microfluidic Devices","abstract":"Various microfluidic structures are devised to generate tunable, stable spatiotemporal chemical gradients for single-cell studies. This work addresses the role of Y-mixer junctions in generating nonlinear gradients by increasing the width of one arm (bias), which is suspected to cause premature diffusion within the mixer. This study introduced a cinching feature to narrow the wider arm locally and redefine the junctions of these biased Y-mixers using four novel geometries defined by a 5-micrometer drawing rule. Furthermore, three flow rate factors allowed us to explore the impact on the generated gradient landscapes. The results showed that the four novel designs similarly increased maximum concentration by an average of 10.8% for the largest mixer arm width and expanded the concentration range along the left side of the chamber. Also, the higher flow rate enhanced maximum chamber concentration by 15.6% and decreased the range along the left side of the chamber by up to 7.83%. Thus, cinching the Y-mixer junctions mitigates premature diffusion, and flow rate modulation optimizes gradient characteristics. Future work is needed to verify simulated results, parameterize channel dimensions based on flow rates, and conduct wet-lab tests to assess sedimentation risk.","abstract_html":"Various microfluidic structures are devised to generate tunable, stable spatiotemporal chemical gradients for single-cell studies. This work addresses the role of Y-mixer junctions in generating nonlinear gradients by increasing the width of one arm (bias), which is suspected to cause premature diffusion within the mixer. This study introduced a cinching feature to narrow the wider arm locally and redefine the junctions of these biased Y-mixers using four novel geometries defined by a 5-micrometer drawing rule. Furthermore, three flow rate factors allowed us to explore the impact on the generated gradient landscapes. The results showed that the four novel designs similarly increased maximum concentration by an average of 10.8% for the largest mixer arm width and expanded the concentration range along the left side of the chamber. Also, the higher flow rate enhanced maximum chamber concentration by 15.6% and decreased the range along the left side of the chamber by up to 7.83%. Thus, cinching the Y-mixer junctions mitigates premature diffusion, and flow rate modulation optimizes gradient characteristics. Future work is needed to verify simulated results, parameterize channel dimensions based on flow rates, and conduct wet-lab tests to assess sedimentation risk.","abstract_has_math":false,"creators":["Thurston Hutton, Elizabeth"],"institution":null,"degree_name":"Master of Science, Applied Physical Science","degree_level":"Thesis (open access)","degree_discipline":"Department of Physics and Astronomy","degree_department":null,"school":null,"contributors":["H. J. Jason Liu","Clayton Heller"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:56:09Z","subjects":["Microfluidics","Chemical gradients","Single-cell studies","Y-mixer","Flow rate","Nonlinear chemical gradients","Analytical Chemistry","Biological and Chemical Physics","Fluid Dynamics"],"languages":[],"rights":[],"rights_urls":["http://creativecommons.org/licenses/by/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.georgiasouthern.edu/etd/2955","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.georgiasouthern.edu/etd/2955","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.georgiasouthern.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.georgiasouthern.edu%3Aetd-4217","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["H. J. Jason Liu","Clayton Heller"]},{"key":"dc:creator","label":"Author","values":["Thurston Hutton, Elizabeth"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-18T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2025-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Department of Physics and Astronomy"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis (open access)"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science, Applied Physical Science"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Microfluidics","Chemical gradients","Single-cell studies","Y-mixer","Flow rate","Nonlinear chemical gradients","Analytical Chemistry","Biological and Chemical Physics","Fluid Dynamics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights.license","label":"Dc Rights License","values":["http://creativecommons.org/licenses/by/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.georgiasouthern.edu/etd/2955"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Various microfluidic structures are devised to generate tunable, stable spatiotemporal chemical gradients for single-cell studies. This work addresses the role of Y-mixer junctions in generating nonlinear gradients by increasing the width of one arm (bias), which is suspected to cause premature diffusion within the mixer. This study introduced a cinching feature to narrow the wider arm locally and redefine the junctions of these biased Y-mixers using four novel geometries defined by a 5-micrometer drawing rule. Furthermore, three flow rate factors allowed us to explore the impact on the generated gradient landscapes. The results showed that the four novel designs similarly increased maximum concentration by an average of 10.8% for the largest mixer arm width and expanded the concentration range along the left side of the chamber. Also, the higher flow rate enhanced maximum chamber concentration by 15.6% and decreased the range along the left side of the chamber by up to 7.83%. Thus, cinching the Y-mixer junctions mitigates premature diffusion, and flow rate modulation optimizes gradient characteristics. Future work is needed to verify simulated results, parameterize channel dimensions based on flow rates, and conduct wet-lab tests to assess sedimentation risk."]},{"key":"dc:source","label":"Dc Source","values":["Thurston Hutton, E. Impact of Y-mixer geometry and flow rate modulation on chemical gradient generators in microfluidic devices. M.S. Thesis, Georgia Southern University, Statesboro, GA, 2025."]},{"key":"dc:title","label":"Title","values":["Impact of Y-Mixer Geometry and Flow Rate Modulation on Chemical Gradient Generators in Microfluidic Devices"]}]}],"canonical_facts":{"dc:contributor":["H. J. Jason Liu","Clayton Heller"],"dc:creator":["Thurston Hutton, Elizabeth"],"dc:date.available":["2025-04-18T07:00:00Z"],"dc:date.created":["2025-01-01T08:00:00Z"],"dc:description.abstract":["Various microfluidic structures are devised to generate tunable, stable spatiotemporal chemical gradients for single-cell studies. This work addresses the role of Y-mixer junctions in generating nonlinear gradients by increasing the width of one arm (bias), which is suspected to cause premature diffusion within the mixer. This study introduced a cinching feature to narrow the wider arm locally and redefine the junctions of these biased Y-mixers using four novel geometries defined by a 5-micrometer drawing rule. Furthermore, three flow rate factors allowed us to explore the impact on the generated gradient landscapes. The results showed that the four novel designs similarly increased maximum concentration by an average of 10.8% for the largest mixer arm width and expanded the concentration range along the left side of the chamber. Also, the higher flow rate enhanced maximum chamber concentration by 15.6% and decreased the range along the left side of the chamber by up to 7.83%. Thus, cinching the Y-mixer junctions mitigates premature diffusion, and flow rate modulation optimizes gradient characteristics. Future work is needed to verify simulated results, parameterize channel dimensions based on flow rates, and conduct wet-lab tests to assess sedimentation risk."],"dc:identifier":["https://digitalcommons.georgiasouthern.edu/etd/2955"],"dc:rights.license":["http://creativecommons.org/licenses/by/4.0/"],"dc:source":["Thurston Hutton, E. Impact of Y-mixer geometry and flow rate modulation on chemical gradient generators in microfluidic devices. M.S. Thesis, Georgia Southern University, Statesboro, GA, 2025."],"dc:subject":["Microfluidics","Chemical gradients","Single-cell studies","Y-mixer","Flow rate","Nonlinear chemical gradients","Analytical Chemistry","Biological and Chemical Physics","Fluid Dynamics"],"dc:title":["Impact of Y-Mixer Geometry and Flow Rate Modulation on Chemical Gradient Generators in Microfluidic Devices"],"thesis:degree_discipline":["Department of Physics and Astronomy"],"thesis:degree_level":["Thesis (open access)"],"thesis:degree_name":["Master of Science, Applied Physical Science"]},"updated_at":"2026-11-19T07:56:09Z"}