{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/10129"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/10129","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Flexibility of bacterial type IV pili determined using atomic force microscopy","abstract":"Type IV pili (T4P) are very thin protein filaments extended and retracted from the surface of certain Gram-negative bacteria. T4P play a major role in processes such as adhesion, twitching motility and biofilm formation. We improve on previous atomic force microscopy (AFM) measurements of the mechanical properties of T4P of Pseudomonas aeruginosa. A protocol was adapted and developed to perform single cell force spectroscopy (SCFS) by adhering a single bacterium to the end of a colloidal cantilever which is brought into contact with a substrate, allowing the pili to adhere. Force-distance curves are then collected by retracting the cantilever, corresponding to the stretching of the T4P. The persistence length, a parameter that characterizes the flexibility of a polymer, can be determined from the worm-like chain (WLC) model. The value of the persistence length measured by total internal reflection fluorescence (TIRF) microscopy is a factor of 1000 times greater than that measured in SCFS experiments. We show that the SCFS protocol is unlikely to be successful without rolling the bacteria beneath the cantilever, which could result in the T4P contacting the adhesive that coats the cantilever. We suggest that the persistence length discrepancy in the literature is due to a force-induced conformational change that occurs when pulling the T4P in the SCFS experiments.","abstract_html":"Type IV pili (T4P) are very thin protein filaments extended and retracted from the surface of certain Gram-negative bacteria. T4P play a major role in processes such as adhesion, twitching motility and biofilm formation. We improve on previous atomic force microscopy (AFM) measurements of the mechanical properties of T4P of Pseudomonas aeruginosa. A protocol was adapted and developed to perform single cell force spectroscopy (SCFS) by adhering a single bacterium to the end of a colloidal cantilever which is brought into contact with a substrate, allowing the pili to adhere. Force-distance curves are then collected by retracting the cantilever, corresponding to the stretching of the T4P. The persistence length, a parameter that characterizes the flexibility of a polymer, can be determined from the worm-like chain (WLC) model. The value of the persistence length measured by total internal reflection fluorescence (TIRF) microscopy is a factor of 1000 times greater than that measured in SCFS experiments. We show that the SCFS protocol is unlikely to be successful without rolling the bacteria beneath the cantilever, which could result in the T4P contacting the adhesive that coats the cantilever. We suggest that the persistence length discrepancy in the literature is due to a force-induced conformational change that occurs when pulling the T4P in the SCFS experiments.","abstract_has_math":false,"creators":["Mogyoros, Joshua"],"institution":"University of Guelph","degree_name":"Master of Science","degree_level":null,"degree_discipline":null,"degree_department":"Department of Physics","school":null,"contributors":[],"advisors":["Dutcher, John"],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016-12-21","date_published":"2016-12-21","updated_at":"2026-11-19T08:27:40Z","subjects":["type IV pili","Pseudomonas aeruginosa","atomic force microscopy","force spectroscopy","polymer physics","biophysics","persistence length","bacteria","physics","biology","biological physics","pili","pilus","flexibility","T4P","single cell force spectroscopy","AFM","SCFS","P. aeruginosa","TIRF","total internal reflection fluorescence","worm-like chain model","WLC"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/10129","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/10129","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F10129","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F10129","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Dutcher, John"]},{"key":"dc:creator","label":"Author","values":["Mogyoros, Joshua"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-12-21T14:36:33Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-12-21T14:36:33Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2016"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2016-12-06"]},{"key":"dc:date.issued","label":"Date","values":["2016-12-21"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Department of Physics"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["type IV pili","Pseudomonas aeruginosa","atomic force microscopy","force spectroscopy","polymer physics","biophysics","persistence length","bacteria","physics","biology","biological physics","pili","pilus","flexibility","T4P","single cell force spectroscopy","AFM","SCFS","P. aeruginosa","TIRF","total internal reflection fluorescence","worm-like chain model","WLC"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10214/10129"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Type IV pili (T4P) are very thin protein filaments extended and retracted from the surface of certain Gram-negative bacteria. T4P play a major role in processes such as adhesion, twitching motility and biofilm formation. We improve on previous atomic force microscopy (AFM) measurements of the mechanical properties of T4P of Pseudomonas aeruginosa. A protocol was adapted and developed to perform single cell force spectroscopy (SCFS) by adhering a single bacterium to the end of a colloidal cantilever which is brought into contact with a substrate, allowing the pili to adhere. Force-distance curves are then collected by retracting the cantilever, corresponding to the stretching of the T4P. The persistence length, a parameter that characterizes the flexibility of a polymer, can be determined from the worm-like chain (WLC) model. The value of the persistence length measured by total internal reflection fluorescence (TIRF) microscopy is a factor of 1000 times greater than that measured in SCFS experiments. We show that the SCFS protocol is unlikely to be successful without rolling the bacteria beneath the cantilever, which could result in the T4P contacting the adhesive that coats the cantilever. We suggest that the persistence length discrepancy in the literature is due to a force-induced conformational change that occurs when pulling the T4P in the SCFS experiments."]},{"key":"dc:title","label":"Title","values":["Flexibility of bacterial type IV pili determined using atomic force microscopy"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Dutcher, John"],"dc:creator":["Mogyoros, Joshua"],"dc:date.accessioned":["2016-12-21T14:36:33Z"],"dc:date.available":["2016-12-21T14:36:33Z"],"dc:date.copyright":["2016"],"dc:date.created":["2016-12-06"],"dc:date.issued":["2016-12-21"],"dc:description.abstract":["Type IV pili (T4P) are very thin protein filaments extended and retracted from the surface of certain Gram-negative bacteria. T4P play a major role in processes such as adhesion, twitching motility and biofilm formation. We improve on previous atomic force microscopy (AFM) measurements of the mechanical properties of T4P of Pseudomonas aeruginosa. A protocol was adapted and developed to perform single cell force spectroscopy (SCFS) by adhering a single bacterium to the end of a colloidal cantilever which is brought into contact with a substrate, allowing the pili to adhere. Force-distance curves are then collected by retracting the cantilever, corresponding to the stretching of the T4P. The persistence length, a parameter that characterizes the flexibility of a polymer, can be determined from the worm-like chain (WLC) model. The value of the persistence length measured by total internal reflection fluorescence (TIRF) microscopy is a factor of 1000 times greater than that measured in SCFS experiments. We show that the SCFS protocol is unlikely to be successful without rolling the bacteria beneath the cantilever, which could result in the T4P contacting the adhesive that coats the cantilever. We suggest that the persistence length discrepancy in the literature is due to a force-induced conformational change that occurs when pulling the T4P in the SCFS experiments."],"dc:identifier.uri":["http://hdl.handle.net/10214/10129"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["type IV pili","Pseudomonas aeruginosa","atomic force microscopy","force spectroscopy","polymer physics","biophysics","persistence length","bacteria","physics","biology","biological physics","pili","pilus","flexibility","T4P","single cell force spectroscopy","AFM","SCFS","P. aeruginosa","TIRF","total internal reflection fluorescence","worm-like chain model","WLC"],"dc:title":["Flexibility of bacterial type IV pili determined using atomic force microscopy"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["Department of Physics"],"thesis:degree_name":["Master of Science"],"thesis:degree_program":["Physics"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:27:40Z"}