{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/10464"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/10464","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Contaminant Mass Distribution of a Mixed Organic Contaminant Plume Down-Gradient of an Aged DNAPL Source Zone in Sedimentary Rock","abstract":"Releases of mixed organic solvent DNAPL occurred before 1970 at an industrial site. The DNAPL migrated through glacial sediments and shallow bedrock, accumulated between 45 and 55 m bgs in a fractured sandstone, and is a persistent source for a large groundwater plume. Here, the contaminant mass variability is characterized using five cored holes along a 238 m long transect orthogonal to groundwater flow and immediately downgradient of the source. Average sample frequency was 4.7 samples per metre. Results show distinct and sometimes unpredictable spatial variability of concentration and composition. One core was located 13 m from a hole cored and sampled in a similar manner 10.5 years earlier. Comparison of results shows an 85% reduction in total VOC mass, attributed mostly to groundwater flushing above the known DNAPL accumulation with evidence for some microbial degradation. These data are foundational to future mass flux estimates and source zone longevity calculations.","abstract_html":"Releases of mixed organic solvent DNAPL occurred before 1970 at an industrial site. The DNAPL migrated through glacial sediments and shallow bedrock, accumulated between 45 and 55 m bgs in a fractured sandstone, and is a persistent source for a large groundwater plume. Here, the contaminant mass variability is characterized using five cored holes along a 238 m long transect orthogonal to groundwater flow and immediately downgradient of the source. Average sample frequency was 4.7 samples per metre. Results show distinct and sometimes unpredictable spatial variability of concentration and composition. One core was located 13 m from a hole cored and sampled in a similar manner 10.5 years earlier. Comparison of results shows an 85% reduction in total VOC mass, attributed mostly to groundwater flushing above the known DNAPL accumulation with evidence for some microbial degradation. These data are foundational to future mass flux estimates and source zone longevity calculations.","abstract_has_math":false,"creators":["Buckley, Andrew Keith"],"institution":"University of Guelph","degree_name":"Master of Applied Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Parker, Beth"],"committee_chairs":[],"committee_members":[],"year":2017,"date_issued":"2017-05-10","date_published":"2017-05-10","updated_at":"2026-11-19T08:25:07Z","subjects":["Contaminant Hydrogeology","Fractured Sedimentary Rock","Transect","Contaminated Groundwater","Discrete Fracture Network (DFN) Approach","Mixed Organic Solvent DNAPL Source Zone"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/10464","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/10464","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F10464","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F10464","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Parker, Beth"]},{"key":"dc:creator","label":"Author","values":["Buckley, Andrew Keith"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2017-05-10T20:15:57Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2017-05-10T20:15:57Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2017"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2017-05-02"]},{"key":"dc:date.issued","label":"Date","values":["2017-05-10"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Contaminant Hydrogeology","Fractured Sedimentary Rock","Transect","Contaminated Groundwater","Discrete Fracture Network (DFN) Approach","Mixed Organic Solvent DNAPL Source Zone"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10214/10464"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Releases of mixed organic solvent DNAPL occurred before 1970 at an industrial site. The DNAPL migrated through glacial sediments and shallow bedrock, accumulated between 45 and 55 m bgs in a fractured sandstone, and is a persistent source for a large groundwater plume. Here, the contaminant mass variability is characterized using five cored holes along a 238 m long transect orthogonal to groundwater flow and immediately downgradient of the source. Average sample frequency was 4.7 samples per metre. Results show distinct and sometimes unpredictable spatial variability of concentration and composition. One core was located 13 m from a hole cored and sampled in a similar manner 10.5 years earlier. Comparison of results shows an 85% reduction in total VOC mass, attributed mostly to groundwater flushing above the known DNAPL accumulation with evidence for some microbial degradation. These data are foundational to future mass flux estimates and source zone longevity calculations."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["Natural Sciences and Engineering Research Council of Canada","Hydrite Chemical Co."]},{"key":"dc:title","label":"Title","values":["Contaminant Mass Distribution of a Mixed Organic Contaminant Plume Down-Gradient of an Aged DNAPL Source Zone in Sedimentary Rock"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Parker, Beth"],"dc:creator":["Buckley, Andrew Keith"],"dc:date.accessioned":["2017-05-10T20:15:57Z"],"dc:date.available":["2017-05-10T20:15:57Z"],"dc:date.copyright":["2017"],"dc:date.created":["2017-05-02"],"dc:date.issued":["2017-05-10"],"dc:description.abstract":["Releases of mixed organic solvent DNAPL occurred before 1970 at an industrial site. The DNAPL migrated through glacial sediments and shallow bedrock, accumulated between 45 and 55 m bgs in a fractured sandstone, and is a persistent source for a large groundwater plume. Here, the contaminant mass variability is characterized using five cored holes along a 238 m long transect orthogonal to groundwater flow and immediately downgradient of the source. Average sample frequency was 4.7 samples per metre. Results show distinct and sometimes unpredictable spatial variability of concentration and composition. One core was located 13 m from a hole cored and sampled in a similar manner 10.5 years earlier. Comparison of results shows an 85% reduction in total VOC mass, attributed mostly to groundwater flushing above the known DNAPL accumulation with evidence for some microbial degradation. These data are foundational to future mass flux estimates and source zone longevity calculations."],"dc:description.sponsorship":["Natural Sciences and Engineering Research Council of Canada","Hydrite Chemical Co."],"dc:identifier.uri":["http://hdl.handle.net/10214/10464"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["Contaminant Hydrogeology","Fractured Sedimentary Rock","Transect","Contaminated Groundwater","Discrete Fracture Network (DFN) Approach","Mixed Organic Solvent DNAPL Source Zone"],"dc:title":["Contaminant Mass Distribution of a Mixed Organic Contaminant Plume Down-Gradient of an Aged DNAPL Source Zone in Sedimentary Rock"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Applied Science"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:25:07Z"}