{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/11604"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/11604","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Experimental and Numerical Investigations of Fluid Flow through Catalytic Converters","abstract":"The need for better automotive technologies to improve fuel economy, while meeting stringent vehicle emission standards, grows with the demand for environmental protection and rising fuel prices. A new technology, designed and patented by Vida Fresh Air Inc., offers emission reduction while improving fuel economy. In this study, experimental and numerical investigations are performed to understand the flow through the catalytic converter, commercially known as CleanalyticTM, using a scaled-down test rig. Experiments are conducted using hot air flow to evaluate the thermalhydraulic characteristics of the new technology. The measurements are performed for Reynolds number of 43,000 and free stream temperature of 177 ºC. These conditions were selected to achieve thermal and hydraulic similarity of actual test conditions for engines. The numerical investigations are performed using ANSYS Fluent and the model predicted the experimental measurements within ±6 %. The use of CleanalyticTM improved the performance of the catalytic converter.","abstract_html":"The need for better automotive technologies to improve fuel economy, while meeting stringent vehicle emission standards, grows with the demand for environmental protection and rising fuel prices. A new technology, designed and patented by Vida Fresh Air Inc., offers emission reduction while improving fuel economy. In this study, experimental and numerical investigations are performed to understand the flow through the catalytic converter, commercially known as CleanalyticTM, using a scaled-down test rig. Experiments are conducted using hot air flow to evaluate the thermalhydraulic characteristics of the new technology. The measurements are performed for Reynolds number of 43,000 and free stream temperature of 177 ºC. These conditions were selected to achieve thermal and hydraulic similarity of actual test conditions for engines. The numerical investigations are performed using ANSYS Fluent and the model predicted the experimental measurements within ±6 %. The use of CleanalyticTM improved the performance of the catalytic converter.","abstract_has_math":false,"creators":["Ibrahim, Hesham"],"institution":"University of Guelph","degree_name":"Master of Applied Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Ahmed, Wael"],"committee_chairs":[],"committee_members":[],"year":2017,"date_issued":"2017-09-15","date_published":"2017-09-15","updated_at":"2026-11-19T08:22:27Z","subjects":["fluid flow","catalytic converters","thermalhydraulic characteristics"],"languages":["en"],"rights":["Attribution-NonCommercial-NoDerivs 2.5 Canada"],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/2.5/ca/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/11604","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/11604","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F11604","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F11604","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ahmed, Wael"]},{"key":"dc:creator","label":"Author","values":["Ibrahim, Hesham"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2017-09-15T19:45:41Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2017-09-15T19:45:41Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2017-09"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2017-09-11"]},{"key":"dc:date.issued","label":"Date","values":["2017-09-15"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["fluid flow","catalytic converters","thermalhydraulic characteristics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution-NonCommercial-NoDerivs 2.5 Canada"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://creativecommons.org/licenses/by-nc-nd/2.5/ca/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10214/11604"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The need for better automotive technologies to improve fuel economy, while meeting stringent vehicle emission standards, grows with the demand for environmental protection and rising fuel prices. A new technology, designed and patented by Vida Fresh Air Inc., offers emission reduction while improving fuel economy. In this study, experimental and numerical investigations are performed to understand the flow through the catalytic converter, commercially known as CleanalyticTM, using a scaled-down test rig. Experiments are conducted using hot air flow to evaluate the thermalhydraulic characteristics of the new technology. The measurements are performed for Reynolds number of 43,000 and free stream temperature of 177 ºC. These conditions were selected to achieve thermal and hydraulic similarity of actual test conditions for engines. The numerical investigations are performed using ANSYS Fluent and the model predicted the experimental measurements within ±6 %. The use of CleanalyticTM improved the performance of the catalytic converter."]},{"key":"dc:title","label":"Title","values":["Experimental and Numerical Investigations of Fluid Flow through Catalytic Converters"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Ahmed, Wael"],"dc:creator":["Ibrahim, Hesham"],"dc:date.accessioned":["2017-09-15T19:45:41Z"],"dc:date.available":["2017-09-15T19:45:41Z"],"dc:date.copyright":["2017-09"],"dc:date.created":["2017-09-11"],"dc:date.issued":["2017-09-15"],"dc:description.abstract":["The need for better automotive technologies to improve fuel economy, while meeting stringent vehicle emission standards, grows with the demand for environmental protection and rising fuel prices. A new technology, designed and patented by Vida Fresh Air Inc., offers emission reduction while improving fuel economy. In this study, experimental and numerical investigations are performed to understand the flow through the catalytic converter, commercially known as CleanalyticTM, using a scaled-down test rig. Experiments are conducted using hot air flow to evaluate the thermalhydraulic characteristics of the new technology. The measurements are performed for Reynolds number of 43,000 and free stream temperature of 177 ºC. These conditions were selected to achieve thermal and hydraulic similarity of actual test conditions for engines. The numerical investigations are performed using ANSYS Fluent and the model predicted the experimental measurements within ±6 %. The use of CleanalyticTM improved the performance of the catalytic converter."],"dc:identifier.uri":["http://hdl.handle.net/10214/11604"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights":["Attribution-NonCommercial-NoDerivs 2.5 Canada"],"dc:rights.uri":["http://creativecommons.org/licenses/by-nc-nd/2.5/ca/"],"dc:subject":["fluid flow","catalytic converters","thermalhydraulic characteristics"],"dc:title":["Experimental and Numerical Investigations of Fluid Flow through Catalytic Converters"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Applied Science"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:22:27Z"}