{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/11923"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/11923","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Finite element analysis of shape memory alloy Niti stent in coronary artery","abstract":"The coronary artery stent is a medical device that treats different coronary diseases. Though in the long run, there is a threat of restenosis, stent recoiling, or stent fracture. Thus, studying the behavior of the Nitinol shape memory alloy stent within hyperelastic model of arterial tissue under different medical conditions is necessary to predict any adverse outcomes. In this research, the stent-artery model is tested within normal human body temperature 36.5 ̊C, and high body temperature 40.0 ̊C, under two conditions of mean arterial pressure (MAP), normal MAP, 70-105 mmHg, and high MAP, 105-140 mmHg. At hypertension, the artery expands to a diameter that is 0.201 mm wider than the original diameter. In addition, the equivalent stress of Nitinol stent increased by 12% at fever and hypertension, however, no recoiling occurred. In conclusion, the stent retracted the artery wall without causing huge stress and safely expanded it with no penetration.","abstract_html":"The coronary artery stent is a medical device that treats different coronary diseases. Though in the long run, there is a threat of restenosis, stent recoiling, or stent fracture. Thus, studying the behavior of the Nitinol shape memory alloy stent within hyperelastic model of arterial tissue under different medical conditions is necessary to predict any adverse outcomes. In this research, the stent-artery model is tested within normal human body temperature 36.5 ̊C, and high body temperature 40.0 ̊C, under two conditions of mean arterial pressure (MAP), normal MAP, 70-105 mmHg, and high MAP, 105-140 mmHg. At hypertension, the artery expands to a diameter that is 0.201 mm wider than the original diameter. In addition, the equivalent stress of Nitinol stent increased by 12% at fever and hypertension, however, no recoiling occurred. In conclusion, the stent retracted the artery wall without causing huge stress and safely expanded it with no penetration.","abstract_has_math":false,"creators":["Al-abassi, Amatulraheem"],"institution":"University of Guelph","degree_name":"Master of Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Deiab, Ibrahim"],"committee_chairs":[],"committee_members":[],"year":2017,"date_issued":"2017-10-16","date_published":"2017-10-16","updated_at":"2026-11-19T08:23:25Z","subjects":["Nitinol Stent","Coronary Artery"],"languages":["en"],"rights":["Attribution-NonCommercial-NoDerivs 2.5 Canada"],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/2.5/ca/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/11923","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/11923","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F11923","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F11923","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Deiab, Ibrahim"]},{"key":"dc:creator","label":"Author","values":["Al-abassi, Amatulraheem"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2017-10-16T19:42:56Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2017-10-16T19:42:56Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2017-10"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2017-10-06"]},{"key":"dc:date.issued","label":"Date","values":["2017-10-16"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Nitinol Stent","Coronary Artery"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution-NonCommercial-NoDerivs 2.5 Canada"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://creativecommons.org/licenses/by-nc-nd/2.5/ca/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10214/11923"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The coronary artery stent is a medical device that treats different coronary diseases. Though in the long run, there is a threat of restenosis, stent recoiling, or stent fracture. Thus, studying the behavior of the Nitinol shape memory alloy stent within hyperelastic model of arterial tissue under different medical conditions is necessary to predict any adverse outcomes. In this research, the stent-artery model is tested within normal human body temperature 36.5 ̊C, and high body temperature 40.0 ̊C, under two conditions of mean arterial pressure (MAP), normal MAP, 70-105 mmHg, and high MAP, 105-140 mmHg. At hypertension, the artery expands to a diameter that is 0.201 mm wider than the original diameter. In addition, the equivalent stress of Nitinol stent increased by 12% at fever and hypertension, however, no recoiling occurred. In conclusion, the stent retracted the artery wall without causing huge stress and safely expanded it with no penetration."]},{"key":"dc:title","label":"Title","values":["Finite element analysis of shape memory alloy Niti stent in coronary artery"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Deiab, Ibrahim"],"dc:creator":["Al-abassi, Amatulraheem"],"dc:date.accessioned":["2017-10-16T19:42:56Z"],"dc:date.available":["2017-10-16T19:42:56Z"],"dc:date.copyright":["2017-10"],"dc:date.created":["2017-10-06"],"dc:date.issued":["2017-10-16"],"dc:description.abstract":["The coronary artery stent is a medical device that treats different coronary diseases. Though in the long run, there is a threat of restenosis, stent recoiling, or stent fracture. Thus, studying the behavior of the Nitinol shape memory alloy stent within hyperelastic model of arterial tissue under different medical conditions is necessary to predict any adverse outcomes. In this research, the stent-artery model is tested within normal human body temperature 36.5 ̊C, and high body temperature 40.0 ̊C, under two conditions of mean arterial pressure (MAP), normal MAP, 70-105 mmHg, and high MAP, 105-140 mmHg. At hypertension, the artery expands to a diameter that is 0.201 mm wider than the original diameter. In addition, the equivalent stress of Nitinol stent increased by 12% at fever and hypertension, however, no recoiling occurred. In conclusion, the stent retracted the artery wall without causing huge stress and safely expanded it with no penetration."],"dc:identifier.uri":["http://hdl.handle.net/10214/11923"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights":["Attribution-NonCommercial-NoDerivs 2.5 Canada"],"dc:rights.uri":["http://creativecommons.org/licenses/by-nc-nd/2.5/ca/"],"dc:subject":["Nitinol Stent","Coronary Artery"],"dc:title":["Finite element analysis of shape memory alloy Niti stent in coronary artery"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Science"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:23:25Z"}