{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/13539"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/13539","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Development of Ammonia and Particulate Matter Emission Factors for a Broiler House with a Heat Exchanger Ventilation System","abstract":"This thesis investigates the ammonia and sized-fractioned particulate matter (PM2.5 and PM10) emission factors for a broiler house equipped with a heat exchanger ventilation system, the Agro Clima Unit, for comparison with conventional broiler house emission factors. The data collection was performed in Bruce County, Ontario during four production cycles over the period of July 2016 to April 2017. The average emission factors for ammonia, PM2.5, and PM10 were found to be 117 ± 98 g day-1 AU-1, 9.30 ± 14.0 g day-1 AU-1, and 15.8 ± 17.7 g day-1 AU-1, respectively. Seasonal variation appeared to have a significant effect on both ammonia and particulate matter emissions. The findings of the study suggest that the Agro Clima Unit may be effectively managing the moisture in the house and, under these drier conditions, less ammonia, and more particulate matter is generated.","abstract_html":"This thesis investigates the ammonia and sized-fractioned particulate matter (PM2.5 and PM10) emission factors for a broiler house equipped with a heat exchanger ventilation system, the Agro Clima Unit, for comparison with conventional broiler house emission factors. The data collection was performed in Bruce County, Ontario during four production cycles over the period of July 2016 to April 2017. The average emission factors for ammonia, PM2.5, and PM10 were found to be 117 ± 98 g day-1 AU-1, 9.30 ± 14.0 g day-1 AU-1, and 15.8 ± 17.7 g day-1 AU-1, respectively. Seasonal variation appeared to have a significant effect on both ammonia and particulate matter emissions. The findings of the study suggest that the Agro Clima Unit may be effectively managing the moisture in the house and, under these drier conditions, less ammonia, and more particulate matter is generated.","abstract_has_math":false,"creators":["Celli, Giulia"],"institution":"University of Guelph","degree_name":"Master of Applied Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Van Heyst, Bill"],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018-06-21","date_published":"2018-06-21","updated_at":"2026-11-19T08:26:14Z","subjects":["particulate matter","emission factor","PM2.5","PM10","broiler","Agro Clima Unit","heat exchanger","ventilation","ammonia","animal production","air emissions"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/13539","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/13539","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F13539","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F13539","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Van Heyst, Bill"]},{"key":"dc:creator","label":"Author","values":["Celli, Giulia"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-06-21T18:39:35Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-06-21T18:39:35Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2018-06"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2018-06-01"]},{"key":"dc:date.issued","label":"Date","values":["2018-06-21"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["particulate matter","emission factor","PM2.5","PM10","broiler","Agro Clima Unit","heat exchanger","ventilation","ammonia","animal production","air emissions"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10214/13539"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis investigates the ammonia and sized-fractioned particulate matter (PM2.5 and PM10) emission factors for a broiler house equipped with a heat exchanger ventilation system, the Agro Clima Unit, for comparison with conventional broiler house emission factors. The data collection was performed in Bruce County, Ontario during four production cycles over the period of July 2016 to April 2017. The average emission factors for ammonia, PM2.5, and PM10 were found to be 117 ± 98 g day-1 AU-1, 9.30 ± 14.0 g day-1 AU-1, and 15.8 ± 17.7 g day-1 AU-1, respectively. Seasonal variation appeared to have a significant effect on both ammonia and particulate matter emissions. The findings of the study suggest that the Agro Clima Unit may be effectively managing the moisture in the house and, under these drier conditions, less ammonia, and more particulate matter is generated."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["Canadian Poultry Research Council","Ontario Ministry of Agriculture, Food and Rural Affairs"]},{"key":"dc:title","label":"Title","values":["Development of Ammonia and Particulate Matter Emission Factors for a Broiler House with a Heat Exchanger Ventilation System"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Van Heyst, Bill"],"dc:creator":["Celli, Giulia"],"dc:date.accessioned":["2018-06-21T18:39:35Z"],"dc:date.available":["2018-06-21T18:39:35Z"],"dc:date.copyright":["2018-06"],"dc:date.created":["2018-06-01"],"dc:date.issued":["2018-06-21"],"dc:description.abstract":["This thesis investigates the ammonia and sized-fractioned particulate matter (PM2.5 and PM10) emission factors for a broiler house equipped with a heat exchanger ventilation system, the Agro Clima Unit, for comparison with conventional broiler house emission factors. The data collection was performed in Bruce County, Ontario during four production cycles over the period of July 2016 to April 2017. The average emission factors for ammonia, PM2.5, and PM10 were found to be 117 ± 98 g day-1 AU-1, 9.30 ± 14.0 g day-1 AU-1, and 15.8 ± 17.7 g day-1 AU-1, respectively. Seasonal variation appeared to have a significant effect on both ammonia and particulate matter emissions. The findings of the study suggest that the Agro Clima Unit may be effectively managing the moisture in the house and, under these drier conditions, less ammonia, and more particulate matter is generated."],"dc:description.sponsorship":["Canadian Poultry Research Council","Ontario Ministry of Agriculture, Food and Rural Affairs"],"dc:identifier.uri":["http://hdl.handle.net/10214/13539"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["particulate matter","emission factor","PM2.5","PM10","broiler","Agro Clima Unit","heat exchanger","ventilation","ammonia","animal production","air emissions"],"dc:title":["Development of Ammonia and Particulate Matter Emission Factors for a Broiler House with a Heat Exchanger Ventilation System"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Applied Science"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:26:14Z"}