{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/14107"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/14107","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Development of an Electrochemical Immunosensing Platform for Detection of Avian Influenza Viruses Using a Hybrid Nanocomposite Scaffold","abstract":"This thesis is an investigation of a sandwich-based electrochemical immunosensor for detection of avian influenza virus (AIV) strains H5N1, H4N6, and H9N2. This sensor was developed using gold-graphene nanocomposites, immobilized viral antibodies, and cadmium telluride (CdTe) quantum dot electrochemical tagging. The nanocomposites were formed by the simultaneous reduction of a gold salt and graphene using hydroquinone as the reducing agent, thus producing non-spherical gold nanoparticles on graphene sheets. Viral antibodies were immobilized on nanocomposites and CdTe quantum dots through N-(3-dimethylaminopropyl)-N′-ethylcarbodiimide and N-hydroxysuccinimide chemistry. Cyclic voltammetry studies were used to validate the detection of H5 surface protein and H4N6 inactivated virus. The immunosensor detected H5 protein in phosphate buffer solution (pH 7.4) with a limit of detection (LOD) of 10 fg/mL and a linear detection range was established for 10 ng/mL to 10 pg/mL. The biosensor detected H4N6 and H9N2 viruses in three parts diluted whole chicken blood with a LOD of 1.28x10-7 hemagglutinating units (HAU). Commercial ELISA testing for H4N6 showed a limit of detection of 0.128 HAU. The sensor showed 106-fold increased detection of H4N6 virus in blood in comparison to its commercial ELISA kit counterpart. The developed immunosensor may effectively change the way avian influenza is detected, monitored, and controlled; transforming time-consuming reactive methods, into rapid predictive technology.","abstract_html":"This thesis is an investigation of a sandwich-based electrochemical immunosensor for detection of avian influenza virus (AIV) strains H5N1, H4N6, and H9N2. This sensor was developed using gold-graphene nanocomposites, immobilized viral antibodies, and cadmium telluride (CdTe) quantum dot electrochemical tagging. The nanocomposites were formed by the simultaneous reduction of a gold salt and graphene using hydroquinone as the reducing agent, thus producing non-spherical gold nanoparticles on graphene sheets. Viral antibodies were immobilized on nanocomposites and CdTe quantum dots through N-(3-dimethylaminopropyl)-N′-ethylcarbodiimide and N-hydroxysuccinimide chemistry. Cyclic voltammetry studies were used to validate the detection of H5 surface protein and H4N6 inactivated virus. The immunosensor detected H5 protein in phosphate buffer solution (pH 7.4) with a limit of detection (LOD) of 10 fg/mL and a linear detection range was established for 10 ng/mL to 10 pg/mL. The biosensor detected H4N6 and H9N2 viruses in three parts diluted whole chicken blood with a LOD of 1.28x10-7 hemagglutinating units (HAU). Commercial ELISA testing for H4N6 showed a limit of detection of 0.128 HAU. The sensor showed 106-fold increased detection of H4N6 virus in blood in comparison to its commercial ELISA kit counterpart. The developed immunosensor may effectively change the way avian influenza is detected, monitored, and controlled; transforming time-consuming reactive methods, into rapid predictive technology.","abstract_has_math":false,"creators":["Buozis, John"],"institution":"University of Guelph","degree_name":"Master of Applied Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Misra, Manjusri","Hayward, Gordon","Gordon, Karen"],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018-08-27","date_published":"2018-08-27","updated_at":"2026-11-19T08:25:07Z","subjects":["Electrochemical Immunosensor","Avian Influenza","H5N1","H4N6","H9N2","Nanocomposites","Point-of-care"],"languages":["en"],"rights":["Attribution-NonCommercial-NoDerivs 2.5 Canada"],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/2.5/ca/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/14107","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/14107","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F14107","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F14107","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Misra, Manjusri","Hayward, Gordon","Gordon, Karen"]},{"key":"dc:creator","label":"Author","values":["Buozis, John"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-08-27T14:15:25Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-08-27T14:15:25Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2018-05"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2018-06-28"]},{"key":"dc:date.issued","label":"Date","values":["2018-08-27"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrochemical Immunosensor","Avian Influenza","H5N1","H4N6","H9N2","Nanocomposites","Point-of-care"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution-NonCommercial-NoDerivs 2.5 Canada"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://creativecommons.org/licenses/by-nc-nd/2.5/ca/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10214/14107"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis is an investigation of a sandwich-based electrochemical immunosensor for detection of avian influenza virus (AIV) strains H5N1, H4N6, and H9N2. This sensor was developed using gold-graphene nanocomposites, immobilized viral antibodies, and cadmium telluride (CdTe) quantum dot electrochemical tagging. The nanocomposites were formed by the simultaneous reduction of a gold salt and graphene using hydroquinone as the reducing agent, thus producing non-spherical gold nanoparticles on graphene sheets. Viral antibodies were immobilized on nanocomposites and CdTe quantum dots through N-(3-dimethylaminopropyl)-N′-ethylcarbodiimide and N-hydroxysuccinimide chemistry. Cyclic voltammetry studies were used to validate the detection of H5 surface protein and H4N6 inactivated virus. The immunosensor detected H5 protein in phosphate buffer solution (pH 7.4) with a limit of detection (LOD) of 10 fg/mL and a linear detection range was established for 10 ng/mL to 10 pg/mL. The biosensor detected H4N6 and H9N2 viruses in three parts diluted whole chicken blood with a LOD of 1.28x10-7 hemagglutinating units (HAU). Commercial ELISA testing for H4N6 showed a limit of detection of 0.128 HAU. The sensor showed 106-fold increased detection of H4N6 virus in blood in comparison to its commercial ELISA kit counterpart. The developed immunosensor may effectively change the way avian influenza is detected, monitored, and controlled; transforming time-consuming reactive methods, into rapid predictive technology."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["Natural Sciences and Engineering Research Council of Canada","Ontario Ministry of Agriculture, Food and Rural Affairs"]},{"key":"dc:title","label":"Title","values":["Development of an Electrochemical Immunosensing Platform for Detection of Avian Influenza Viruses Using a Hybrid Nanocomposite Scaffold"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Misra, Manjusri","Hayward, Gordon","Gordon, Karen"],"dc:creator":["Buozis, John"],"dc:date.accessioned":["2018-08-27T14:15:25Z"],"dc:date.available":["2018-08-27T14:15:25Z"],"dc:date.copyright":["2018-05"],"dc:date.created":["2018-06-28"],"dc:date.issued":["2018-08-27"],"dc:description.abstract":["This thesis is an investigation of a sandwich-based electrochemical immunosensor for detection of avian influenza virus (AIV) strains H5N1, H4N6, and H9N2. This sensor was developed using gold-graphene nanocomposites, immobilized viral antibodies, and cadmium telluride (CdTe) quantum dot electrochemical tagging. The nanocomposites were formed by the simultaneous reduction of a gold salt and graphene using hydroquinone as the reducing agent, thus producing non-spherical gold nanoparticles on graphene sheets. Viral antibodies were immobilized on nanocomposites and CdTe quantum dots through N-(3-dimethylaminopropyl)-N′-ethylcarbodiimide and N-hydroxysuccinimide chemistry. Cyclic voltammetry studies were used to validate the detection of H5 surface protein and H4N6 inactivated virus. The immunosensor detected H5 protein in phosphate buffer solution (pH 7.4) with a limit of detection (LOD) of 10 fg/mL and a linear detection range was established for 10 ng/mL to 10 pg/mL. The biosensor detected H4N6 and H9N2 viruses in three parts diluted whole chicken blood with a LOD of 1.28x10-7 hemagglutinating units (HAU). Commercial ELISA testing for H4N6 showed a limit of detection of 0.128 HAU. The sensor showed 106-fold increased detection of H4N6 virus in blood in comparison to its commercial ELISA kit counterpart. The developed immunosensor may effectively change the way avian influenza is detected, monitored, and controlled; transforming time-consuming reactive methods, into rapid predictive technology."],"dc:description.sponsorship":["Natural Sciences and Engineering Research Council of Canada","Ontario Ministry of Agriculture, Food and Rural Affairs"],"dc:identifier.uri":["http://hdl.handle.net/10214/14107"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights":["Attribution-NonCommercial-NoDerivs 2.5 Canada"],"dc:rights.uri":["http://creativecommons.org/licenses/by-nc-nd/2.5/ca/"],"dc:subject":["Electrochemical Immunosensor","Avian Influenza","H5N1","H4N6","H9N2","Nanocomposites","Point-of-care"],"dc:title":["Development of an Electrochemical Immunosensing Platform for Detection of Avian Influenza Viruses Using a Hybrid Nanocomposite Scaffold"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Applied Science"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:25:07Z"}