{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/14653"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/14653","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"UV light-based interventions to inactivate pathogens on fresh produce through the use of UV-LEDs and water-assisted processing","abstract":"Germicidal efficacies of a low pressure mercury lamp and UV-LEDs were compared for E. coli, Listeria, and Salmonella. UV-LEDs emitting at 259 and 268 nm were most effective in pathogen inactivation. Synergistic lethality occurred between 259 and 289 nm light applied simultaneously. The efficacy of dry and \"water-assisted\" UV254 treatment, and treatment with 277 nm UV-LEDs at 4 and 25°C for the inactivation of pathogens on apples and lettuce was examined. An LPM lamp emitting light at 254 nm was more effective in the dry treatment of E. coli O157:H7 on lettuce, while UV-LEDs at 277 nm were more effective against L. monocytogenes on apples. Water-assisted treatment was more effective overall than direct illumination because the majority of bacteria were released into the water and then inactivated by UV light. UV-LEDs have increased power output but similar germicidal efficacy at 4°C vs. 25°C, validating their use in temperature-controlled facilities.","abstract_html":"Germicidal efficacies of a low pressure mercury lamp and UV-LEDs were compared for E. coli, Listeria, and Salmonella. UV-LEDs emitting at 259 and 268 nm were most effective in pathogen inactivation. Synergistic lethality occurred between 259 and 289 nm light applied simultaneously. The efficacy of dry and &quot;water-assisted&quot; UV254 treatment, and treatment with 277 nm UV-LEDs at 4 and 25°C for the inactivation of pathogens on apples and lettuce was examined. An LPM lamp emitting light at 254 nm was more effective in the dry treatment of E. coli O157:H7 on lettuce, while UV-LEDs at 277 nm were more effective against L. monocytogenes on apples. Water-assisted treatment was more effective overall than direct illumination because the majority of bacteria were released into the water and then inactivated by UV light. UV-LEDs have increased power output but similar germicidal efficacy at 4°C vs. 25°C, validating their use in temperature-controlled facilities.","abstract_has_math":false,"creators":["Green, Andrew"],"institution":"University of Guelph","degree_name":"Master of Science","degree_level":null,"degree_discipline":null,"degree_department":"Department of Food Science","school":null,"contributors":[],"advisors":["Warriner, Keith"],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018-12-17","date_published":"2018-12-17","updated_at":"2026-11-19T08:22:03Z","subjects":["fresh produce","ultraviolet","light emitting diode","food-borne pathogen"],"languages":["en"],"rights":["Attribution 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10214/14653","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10214/14653","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F14653","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Warriner, Keith"]},{"key":"dc:creator","label":"Author","values":["Green, Andrew"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-12-17T16:53:10Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-12-17T16:53:10Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2018-08"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2018-12-07"]},{"key":"dc:date.issued","label":"Date","values":["2018-12-17"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Department of Food Science"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Food Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["fresh produce","ultraviolet","light emitting diode","food-borne pathogen"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution 4.0 International"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://creativecommons.org/licenses/by/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10214/14653"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Germicidal efficacies of a low pressure mercury lamp and UV-LEDs were compared for E. coli, Listeria, and Salmonella. UV-LEDs emitting at 259 and 268 nm were most effective in pathogen inactivation. Synergistic lethality occurred between 259 and 289 nm light applied simultaneously. The efficacy of dry and \"water-assisted\" UV254 treatment, and treatment with 277 nm UV-LEDs at 4 and 25°C for the inactivation of pathogens on apples and lettuce was examined. An LPM lamp emitting light at 254 nm was more effective in the dry treatment of E. coli O157:H7 on lettuce, while UV-LEDs at 277 nm were more effective against L. monocytogenes on apples. Water-assisted treatment was more effective overall than direct illumination because the majority of bacteria were released into the water and then inactivated by UV light. UV-LEDs have increased power output but similar germicidal efficacy at 4°C vs. 25°C, validating their use in temperature-controlled facilities."]},{"key":"dc:title","label":"Title","values":["UV light-based interventions to inactivate pathogens on fresh produce through the use of UV-LEDs and water-assisted processing"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Warriner, Keith"],"dc:creator":["Green, Andrew"],"dc:date.accessioned":["2018-12-17T16:53:10Z"],"dc:date.available":["2018-12-17T16:53:10Z"],"dc:date.copyright":["2018-08"],"dc:date.created":["2018-12-07"],"dc:date.issued":["2018-12-17"],"dc:description.abstract":["Germicidal efficacies of a low pressure mercury lamp and UV-LEDs were compared for E. coli, Listeria, and Salmonella. UV-LEDs emitting at 259 and 268 nm were most effective in pathogen inactivation. Synergistic lethality occurred between 259 and 289 nm light applied simultaneously. The efficacy of dry and \"water-assisted\" UV254 treatment, and treatment with 277 nm UV-LEDs at 4 and 25°C for the inactivation of pathogens on apples and lettuce was examined. An LPM lamp emitting light at 254 nm was more effective in the dry treatment of E. coli O157:H7 on lettuce, while UV-LEDs at 277 nm were more effective against L. monocytogenes on apples. Water-assisted treatment was more effective overall than direct illumination because the majority of bacteria were released into the water and then inactivated by UV light. UV-LEDs have increased power output but similar germicidal efficacy at 4°C vs. 25°C, validating their use in temperature-controlled facilities."],"dc:identifier.uri":["http://hdl.handle.net/10214/14653"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights":["Attribution 4.0 International"],"dc:rights.uri":["http://creativecommons.org/licenses/by/4.0/"],"dc:subject":["fresh produce","ultraviolet","light emitting diode","food-borne pathogen"],"dc:title":["UV light-based interventions to inactivate pathogens on fresh produce through the use of UV-LEDs and water-assisted processing"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["Department of Food Science"],"thesis:degree_name":["Master of Science"],"thesis:degree_program":["Food Science"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:22:03Z"}