{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/14772"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/14772","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Application of Low Pressure Reverse Osmosis Membranes for the treatment of UASB effluent","abstract":"Research was completed on the performance of low energy reverse osmosis membranes for the treatment of Upflow Anaerobic Sludge Bioreactor (UASB) effluent with the goal of water reuse. The parameters studied were included the flux profile, constituent rejection, and membrane resistance changes. An investigation into the effectiveness of pre-treatment by GAC column and a study of fouling characteristics was also completed. Wastewater was taken from an industrial partner who operated an industrial scale UASB used to treat is brewery effluent. The studied RO membranes showed between 94-96% COD rejection, 93-96% TP rejection, and 68-80% TN rejection. The effluent quality met the reused guidelines put forth by the US EPA, however limits found in case studies suggest that the effluent quality is high in both salinity and COD. A GAC column was found to improve the flux and rejection of all membranes. Calcium was identified as the main inorganic foulant.","abstract_html":"Research was completed on the performance of low energy reverse osmosis membranes for the treatment of Upflow Anaerobic Sludge Bioreactor (UASB) effluent with the goal of water reuse. The parameters studied were included the flux profile, constituent rejection, and membrane resistance changes. An investigation into the effectiveness of pre-treatment by GAC column and a study of fouling characteristics was also completed. Wastewater was taken from an industrial partner who operated an industrial scale UASB used to treat is brewery effluent. The studied RO membranes showed between 94-96% COD rejection, 93-96% TP rejection, and 68-80% TN rejection. The effluent quality met the reused guidelines put forth by the US EPA, however limits found in case studies suggest that the effluent quality is high in both salinity and COD. A GAC column was found to improve the flux and rejection of all membranes. Calcium was identified as the main inorganic foulant.","abstract_has_math":false,"creators":["Innes, Peter"],"institution":"University of Guelph","degree_name":"Master of Applied Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Chang, Sheng"],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019-01-11","date_published":"2019-01-11","updated_at":"2026-11-19T08:24:16Z","subjects":["Reverse Osmosis","UASB","Water Reuse"],"languages":["en"],"rights":["Attribution-NoDerivatives 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by-nd/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/14772","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/14772","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F14772","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F14772","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Chang, Sheng"]},{"key":"dc:creator","label":"Author","values":["Innes, Peter"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-01-11T18:03:41Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2019-01-11T18:03:41Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2019-01"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2019-01-09"]},{"key":"dc:date.issued","label":"Date","values":["2019-01-11"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Reverse Osmosis","UASB","Water Reuse"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution-NoDerivatives 4.0 International"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://creativecommons.org/licenses/by-nd/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10214/14772"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Research was completed on the performance of low energy reverse osmosis membranes for the treatment of Upflow Anaerobic Sludge Bioreactor (UASB) effluent with the goal of water reuse. The parameters studied were included the flux profile, constituent rejection, and membrane resistance changes. An investigation into the effectiveness of pre-treatment by GAC column and a study of fouling characteristics was also completed. Wastewater was taken from an industrial partner who operated an industrial scale UASB used to treat is brewery effluent. The studied RO membranes showed between 94-96% COD rejection, 93-96% TP rejection, and 68-80% TN rejection. The effluent quality met the reused guidelines put forth by the US EPA, however limits found in case studies suggest that the effluent quality is high in both salinity and COD. A GAC column was found to improve the flux and rejection of all membranes. Calcium was identified as the main inorganic foulant."]},{"key":"dc:title","label":"Title","values":["Application of Low Pressure Reverse Osmosis Membranes for the treatment of UASB effluent"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Chang, Sheng"],"dc:creator":["Innes, Peter"],"dc:date.accessioned":["2019-01-11T18:03:41Z"],"dc:date.available":["2019-01-11T18:03:41Z"],"dc:date.copyright":["2019-01"],"dc:date.created":["2019-01-09"],"dc:date.issued":["2019-01-11"],"dc:description.abstract":["Research was completed on the performance of low energy reverse osmosis membranes for the treatment of Upflow Anaerobic Sludge Bioreactor (UASB) effluent with the goal of water reuse. The parameters studied were included the flux profile, constituent rejection, and membrane resistance changes. An investigation into the effectiveness of pre-treatment by GAC column and a study of fouling characteristics was also completed. Wastewater was taken from an industrial partner who operated an industrial scale UASB used to treat is brewery effluent. The studied RO membranes showed between 94-96% COD rejection, 93-96% TP rejection, and 68-80% TN rejection. The effluent quality met the reused guidelines put forth by the US EPA, however limits found in case studies suggest that the effluent quality is high in both salinity and COD. A GAC column was found to improve the flux and rejection of all membranes. Calcium was identified as the main inorganic foulant."],"dc:identifier.uri":["http://hdl.handle.net/10214/14772"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights":["Attribution-NoDerivatives 4.0 International"],"dc:rights.uri":["http://creativecommons.org/licenses/by-nd/4.0/"],"dc:subject":["Reverse Osmosis","UASB","Water Reuse"],"dc:title":["Application of Low Pressure Reverse Osmosis Membranes for the treatment of UASB effluent"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Applied Science"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:24:16Z"}