{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/17372"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/17372","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Investigating the Performance Degradation of Centrifugal Pumps","abstract":"Centrifugal pumps are used in a variety of engineering applications such as power production, heating, cooling, and water distribution systems. Although centrifugal pumps are considered to be highly reliable hydraulic machines, they are susceptible to a wide range of damages due to several degradation mechanisms, operating away from the best efficiency point and improper installation. The most common forms of condition monitoring for rotating machines performance monitoring coupled with vibration analysis. The goal of this thesis is to document the performance degradation and vibration characteristics for an industrial scale centrifugal pump subjected to specific forms of damage, in particular impeller unbalance. In this work a 7.5 kW centrifugal pump rated for a flow rate of 17 L/s and 23 m of pressure head is tested in a state-of-the-art pump experimental setup, equipped with a wide range of sensors and control devices. Extensive performance and vibration measurements were collected to evaluate the effects of various levels of impeller unbalance using the time and frequency domain techniques coupled with principal component analysis. The results from this work can be used to evaluate and monitor the pump performance under prescribed degradation in order to enhance the preventative maintenance program.","abstract_html":"Centrifugal pumps are used in a variety of engineering applications such as power production, heating, cooling, and water distribution systems. Although centrifugal pumps are considered to be highly reliable hydraulic machines, they are susceptible to a wide range of damages due to several degradation mechanisms, operating away from the best efficiency point and improper installation. The most common forms of condition monitoring for rotating machines performance monitoring coupled with vibration analysis. The goal of this thesis is to document the performance degradation and vibration characteristics for an industrial scale centrifugal pump subjected to specific forms of damage, in particular impeller unbalance. In this work a 7.5 kW centrifugal pump rated for a flow rate of 17 L/s and 23 m of pressure head is tested in a state-of-the-art pump experimental setup, equipped with a wide range of sensors and control devices. Extensive performance and vibration measurements were collected to evaluate the effects of various levels of impeller unbalance using the time and frequency domain techniques coupled with principal component analysis. The results from this work can be used to evaluate and monitor the pump performance under prescribed degradation in order to enhance the preventative maintenance program.","abstract_has_math":false,"creators":["Eaton, Andrew"],"institution":"University of Guelph","degree_name":"Master of Applied Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Ahmed, Wael","Hassan, Marwan"],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019-09-04","date_published":"2019-09-04","updated_at":"2026-11-19T08:25:14Z","subjects":["Centrifugal Pumps","Impeller unbalance","Vibration","Performance Degradation"],"languages":["en"],"rights":["Attribution-NoDerivatives 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by-nd/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/17372","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/17372","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F17372","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F17372","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ahmed, Wael","Hassan, Marwan"]},{"key":"dc:creator","label":"Author","values":["Eaton, Andrew"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-09-04T19:52:12Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2020-07-02T05:00:42Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2019-07"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2019-07-02"]},{"key":"dc:date.issued","label":"Date","values":["2019-09-04"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Centrifugal Pumps","Impeller unbalance","Vibration","Performance Degradation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution-NoDerivatives 4.0 International"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://creativecommons.org/licenses/by-nd/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10214/17372"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Centrifugal pumps are used in a variety of engineering applications such as power production, heating, cooling, and water distribution systems. Although centrifugal pumps are considered to be highly reliable hydraulic machines, they are susceptible to a wide range of damages due to several degradation mechanisms, operating away from the best efficiency point and improper installation. The most common forms of condition monitoring for rotating machines performance monitoring coupled with vibration analysis. The goal of this thesis is to document the performance degradation and vibration characteristics for an industrial scale centrifugal pump subjected to specific forms of damage, in particular impeller unbalance. In this work a 7.5 kW centrifugal pump rated for a flow rate of 17 L/s and 23 m of pressure head is tested in a state-of-the-art pump experimental setup, equipped with a wide range of sensors and control devices. Extensive performance and vibration measurements were collected to evaluate the effects of various levels of impeller unbalance using the time and frequency domain techniques coupled with principal component analysis. The results from this work can be used to evaluate and monitor the pump performance under prescribed degradation in order to enhance the preventative maintenance program."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["Natural Sciences and Engineering Research Council of Canada","Xylem Inc."]},{"key":"dc:title","label":"Title","values":["Investigating the Performance Degradation of Centrifugal Pumps"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Ahmed, Wael","Hassan, Marwan"],"dc:creator":["Eaton, Andrew"],"dc:date.accessioned":["2019-09-04T19:52:12Z"],"dc:date.available":["2020-07-02T05:00:42Z"],"dc:date.copyright":["2019-07"],"dc:date.created":["2019-07-02"],"dc:date.issued":["2019-09-04"],"dc:description.abstract":["Centrifugal pumps are used in a variety of engineering applications such as power production, heating, cooling, and water distribution systems. Although centrifugal pumps are considered to be highly reliable hydraulic machines, they are susceptible to a wide range of damages due to several degradation mechanisms, operating away from the best efficiency point and improper installation. The most common forms of condition monitoring for rotating machines performance monitoring coupled with vibration analysis. The goal of this thesis is to document the performance degradation and vibration characteristics for an industrial scale centrifugal pump subjected to specific forms of damage, in particular impeller unbalance. In this work a 7.5 kW centrifugal pump rated for a flow rate of 17 L/s and 23 m of pressure head is tested in a state-of-the-art pump experimental setup, equipped with a wide range of sensors and control devices. Extensive performance and vibration measurements were collected to evaluate the effects of various levels of impeller unbalance using the time and frequency domain techniques coupled with principal component analysis. The results from this work can be used to evaluate and monitor the pump performance under prescribed degradation in order to enhance the preventative maintenance program."],"dc:description.sponsorship":["Natural Sciences and Engineering Research Council of Canada","Xylem Inc."],"dc:identifier.uri":["http://hdl.handle.net/10214/17372"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights":["Attribution-NoDerivatives 4.0 International"],"dc:rights.uri":["http://creativecommons.org/licenses/by-nd/4.0/"],"dc:subject":["Centrifugal Pumps","Impeller unbalance","Vibration","Performance Degradation"],"dc:title":["Investigating the Performance Degradation of Centrifugal Pumps"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Applied Science"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:25:14Z"}