{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/17451"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/17451","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Sensitivity of Bulk Leg Tissue Stiffness to Muscle Activation","abstract":"Lower limb tissue stiffness is contingent on various factors, including body composition, loading rates, and the geometry of the indenting object. In comparison to more conventional engineering materials, biological soft tissues possess complicated structures that exhibit unique nonlinear mechanical behaviour. Being able to predict the gross mechanical behaviour of human soft tissue under different loading conditions could enable researchers and engineers to improve the performance of biomedical devices through optimized human-device interfaces. In this study, a custom-built handheld indentation device was used to explore changes in leg tissue stiffness at rest and during isometric contractions. Corresponding force-displacement relationships were modelled using a two-parameter exponential growth function. Averaged across 18 subjects and two indentation locations (thigh/shank), deformation forces during activation increased by a factor of ~1.6x over the same displacement as inactive data. Thus, bulk tissue stiffness varies dramatically with underlying muscle activation; this should be considered in developing novel orthoses.","abstract_html":"Lower limb tissue stiffness is contingent on various factors, including body composition, loading rates, and the geometry of the indenting object. In comparison to more conventional engineering materials, biological soft tissues possess complicated structures that exhibit unique nonlinear mechanical behaviour. Being able to predict the gross mechanical behaviour of human soft tissue under different loading conditions could enable researchers and engineers to improve the performance of biomedical devices through optimized human-device interfaces. In this study, a custom-built handheld indentation device was used to explore changes in leg tissue stiffness at rest and during isometric contractions. Corresponding force-displacement relationships were modelled using a two-parameter exponential growth function. Averaged across 18 subjects and two indentation locations (thigh/shank), deformation forces during activation increased by a factor of ~1.6x over the same displacement as inactive data. Thus, bulk tissue stiffness varies dramatically with underlying muscle activation; this should be considered in developing novel orthoses.","abstract_has_math":false,"creators":["Bosnic, Matija"],"institution":"University of Guelph","degree_name":"Master of Applied Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Brandon, Scott"],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019-09-12","date_published":"2019-09-12","updated_at":"2026-11-19T08:20:51Z","subjects":["Soft Tissue","Activation","Stiffness","Exponential Model","Mechanical Behaviour","Indentation"],"languages":["en"],"rights":["Attribution 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/17451","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/17451","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F17451","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F17451","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Brandon, Scott"]},{"key":"dc:creator","label":"Author","values":["Bosnic, Matija"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-09-12T15:08:30Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2019-09-12T15:08:30Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2019-09"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2019-09-10"]},{"key":"dc:date.issued","label":"Date","values":["2019-09-12"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Soft Tissue","Activation","Stiffness","Exponential Model","Mechanical Behaviour","Indentation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution 4.0 International"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://creativecommons.org/licenses/by/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10214/17451"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Lower limb tissue stiffness is contingent on various factors, including body composition, loading rates, and the geometry of the indenting object. In comparison to more conventional engineering materials, biological soft tissues possess complicated structures that exhibit unique nonlinear mechanical behaviour. Being able to predict the gross mechanical behaviour of human soft tissue under different loading conditions could enable researchers and engineers to improve the performance of biomedical devices through optimized human-device interfaces. In this study, a custom-built handheld indentation device was used to explore changes in leg tissue stiffness at rest and during isometric contractions. Corresponding force-displacement relationships were modelled using a two-parameter exponential growth function. Averaged across 18 subjects and two indentation locations (thigh/shank), deformation forces during activation increased by a factor of ~1.6x over the same displacement as inactive data. Thus, bulk tissue stiffness varies dramatically with underlying muscle activation; this should be considered in developing novel orthoses."]},{"key":"dc:title","label":"Title","values":["Sensitivity of Bulk Leg Tissue Stiffness to Muscle Activation"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Brandon, Scott"],"dc:creator":["Bosnic, Matija"],"dc:date.accessioned":["2019-09-12T15:08:30Z"],"dc:date.available":["2019-09-12T15:08:30Z"],"dc:date.copyright":["2019-09"],"dc:date.created":["2019-09-10"],"dc:date.issued":["2019-09-12"],"dc:description.abstract":["Lower limb tissue stiffness is contingent on various factors, including body composition, loading rates, and the geometry of the indenting object. In comparison to more conventional engineering materials, biological soft tissues possess complicated structures that exhibit unique nonlinear mechanical behaviour. Being able to predict the gross mechanical behaviour of human soft tissue under different loading conditions could enable researchers and engineers to improve the performance of biomedical devices through optimized human-device interfaces. In this study, a custom-built handheld indentation device was used to explore changes in leg tissue stiffness at rest and during isometric contractions. Corresponding force-displacement relationships were modelled using a two-parameter exponential growth function. Averaged across 18 subjects and two indentation locations (thigh/shank), deformation forces during activation increased by a factor of ~1.6x over the same displacement as inactive data. Thus, bulk tissue stiffness varies dramatically with underlying muscle activation; this should be considered in developing novel orthoses."],"dc:identifier.uri":["http://hdl.handle.net/10214/17451"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights":["Attribution 4.0 International"],"dc:rights.uri":["http://creativecommons.org/licenses/by/4.0/"],"dc:subject":["Soft Tissue","Activation","Stiffness","Exponential Model","Mechanical Behaviour","Indentation"],"dc:title":["Sensitivity of Bulk Leg Tissue Stiffness to Muscle Activation"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Applied Science"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:20:51Z"}