{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/17660"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/17660","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Quantification of Light Elements by the Mars Science Laboratory's Alpha Particle X-ray Spectrometer using Absolute Rayleigh Scatter Peak Analysis","abstract":"The Mars Science Laboratory’s Alpha Particle X-ray Spectrometer (APXS) performs bulk-chemistry analyses on the surface of Mars. It is capable of quantifying elements Z>10 through its primary mechanisms of X-Ray Fluorescence and Particle Induced X-ray Emission. The APXS is indirectly able to quantify \"invisible\" light elements with atomic number Z<11, such as water or carbonates which cannot be detected. Traditional means for quantifying invisible elements make use of APXS scatter peaks by analyzing relative intensities of measured Compton and Rayleigh X-ray peaks. The work presented in this thesis approaches the quantification of invisibles by making analytical predictions of scatter peaks on an absolute scale, rather than relative. This allows one to use Rayleigh absolute scatter peaks as a measure of distance, while simultaneously determining invisibles. The method has also extended previous work by incorporating invisibles into the compositional matrix to iteratively determine concentrations in the presence of invisibles.","abstract_html":"The Mars Science Laboratory’s Alpha Particle X-ray Spectrometer (APXS) performs bulk-chemistry analyses on the surface of Mars. It is capable of quantifying elements Z&gt;10 through its primary mechanisms of X-Ray Fluorescence and Particle Induced X-ray Emission. The APXS is indirectly able to quantify &quot;invisible&quot; light elements with atomic number Z&lt;11, such as water or carbonates which cannot be detected. Traditional means for quantifying invisible elements make use of APXS scatter peaks by analyzing relative intensities of measured Compton and Rayleigh X-ray peaks. The work presented in this thesis approaches the quantification of invisibles by making analytical predictions of scatter peaks on an absolute scale, rather than relative. This allows one to use Rayleigh absolute scatter peaks as a measure of distance, while simultaneously determining invisibles. The method has also extended previous work by incorporating invisibles into the compositional matrix to iteratively determine concentrations in the presence of invisibles.","abstract_has_math":false,"creators":["Hanania, Jordan"],"institution":"University of Guelph","degree_name":"Master of Science","degree_level":null,"degree_discipline":null,"degree_department":"Department of Physics","school":null,"contributors":[],"advisors":["Gellert, Ralf"],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019-12-17","date_published":"2019-12-17","updated_at":"2026-11-19T08:21:13Z","subjects":["X-ray Spectrometry","Alpha Particle X-ray Spectrometer","Mars","Space Science","Instrumentation","Curiosity Rover","Rayleigh scattering","X-ray physics"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/17660","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/17660","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F17660","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F17660","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Gellert, Ralf"]},{"key":"dc:creator","label":"Author","values":["Hanania, Jordan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-12-17T20:50:03Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2019-12-17T20:50:03Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2019-12"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2019-12-11"]},{"key":"dc:date.issued","label":"Date","values":["2019-12-17"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Department of Physics"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["X-ray Spectrometry","Alpha Particle X-ray Spectrometer","Mars","Space Science","Instrumentation","Curiosity Rover","Rayleigh scattering","X-ray physics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10214/17660"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The Mars Science Laboratory’s Alpha Particle X-ray Spectrometer (APXS) performs bulk-chemistry analyses on the surface of Mars. It is capable of quantifying elements Z>10 through its primary mechanisms of X-Ray Fluorescence and Particle Induced X-ray Emission. The APXS is indirectly able to quantify \"invisible\" light elements with atomic number Z<11, such as water or carbonates which cannot be detected. Traditional means for quantifying invisible elements make use of APXS scatter peaks by analyzing relative intensities of measured Compton and Rayleigh X-ray peaks. The work presented in this thesis approaches the quantification of invisibles by making analytical predictions of scatter peaks on an absolute scale, rather than relative. This allows one to use Rayleigh absolute scatter peaks as a measure of distance, while simultaneously determining invisibles. The method has also extended previous work by incorporating invisibles into the compositional matrix to iteratively determine concentrations in the presence of invisibles."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["Canadian Space Agency"]},{"key":"dc:title","label":"Title","values":["Quantification of Light Elements by the Mars Science Laboratory's Alpha Particle X-ray Spectrometer using Absolute Rayleigh Scatter Peak Analysis"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Gellert, Ralf"],"dc:creator":["Hanania, Jordan"],"dc:date.accessioned":["2019-12-17T20:50:03Z"],"dc:date.available":["2019-12-17T20:50:03Z"],"dc:date.copyright":["2019-12"],"dc:date.created":["2019-12-11"],"dc:date.issued":["2019-12-17"],"dc:description.abstract":["The Mars Science Laboratory’s Alpha Particle X-ray Spectrometer (APXS) performs bulk-chemistry analyses on the surface of Mars. It is capable of quantifying elements Z>10 through its primary mechanisms of X-Ray Fluorescence and Particle Induced X-ray Emission. The APXS is indirectly able to quantify \"invisible\" light elements with atomic number Z<11, such as water or carbonates which cannot be detected. Traditional means for quantifying invisible elements make use of APXS scatter peaks by analyzing relative intensities of measured Compton and Rayleigh X-ray peaks. The work presented in this thesis approaches the quantification of invisibles by making analytical predictions of scatter peaks on an absolute scale, rather than relative. This allows one to use Rayleigh absolute scatter peaks as a measure of distance, while simultaneously determining invisibles. The method has also extended previous work by incorporating invisibles into the compositional matrix to iteratively determine concentrations in the presence of invisibles."],"dc:description.sponsorship":["Canadian Space Agency"],"dc:identifier.uri":["http://hdl.handle.net/10214/17660"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["X-ray Spectrometry","Alpha Particle X-ray Spectrometer","Mars","Space Science","Instrumentation","Curiosity Rover","Rayleigh scattering","X-ray physics"],"dc:title":["Quantification of Light Elements by the Mars Science Laboratory's Alpha Particle X-ray Spectrometer using Absolute Rayleigh Scatter Peak Analysis"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["Department of Physics"],"thesis:degree_name":["Master of Science"],"thesis:degree_program":["Physics"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:21:13Z"}