{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/17667"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/17667","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Estimation of evapotranspiration from a bioretention facility using a lysimeter and six predictive equations","abstract":"Low impact development practices such as bioretention are being used more frequently in stormwater management. The commonly considered aspects of bioretention are its ability for filtration and infiltration, but evapotranspiration is not frequently considered despite its potential to be a significant component of the water balance. A lysimeter study was conducted in Guelph, Ontario to estimate the ET rate from bioretention facilities. The lysimeter was designed to mimic standard bioretention design parameters. The average annual ET rate was 1.30 mm/d, with monthly averages ranging from -0.009-2.90 mm/d. The lysimeter-derived ET was then compared to ET predicted by the Hamon, Hargreaves-Samani, Jensen-Haise, Penman-Monteith, Priestley-Taylor, and Thorthwaite equations to determine their applicability to use in urban bioretention systems. The Jensen-Haise equation was found to perform the best once a coefficient of 0.5 was applied to consider the protected environment of the lysimeter.","abstract_html":"Low impact development practices such as bioretention are being used more frequently in stormwater management. The commonly considered aspects of bioretention are its ability for filtration and infiltration, but evapotranspiration is not frequently considered despite its potential to be a significant component of the water balance. A lysimeter study was conducted in Guelph, Ontario to estimate the ET rate from bioretention facilities. The lysimeter was designed to mimic standard bioretention design parameters. The average annual ET rate was 1.30 mm/d, with monthly averages ranging from -0.009-2.90 mm/d. The lysimeter-derived ET was then compared to ET predicted by the Hamon, Hargreaves-Samani, Jensen-Haise, Penman-Monteith, Priestley-Taylor, and Thorthwaite equations to determine their applicability to use in urban bioretention systems. The Jensen-Haise equation was found to perform the best once a coefficient of 0.5 was applied to consider the protected environment of the lysimeter.","abstract_has_math":false,"creators":["Gingrich Regehr, Alison"],"institution":"University of Guelph","degree_name":"Master of Applied Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Bradford, Andrea"],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019-12-18","date_published":"2019-12-18","updated_at":"2026-11-19T08:25:00Z","subjects":["bioretention","evapotranspiration"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/17667","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/17667","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F17667","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F17667","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Bradford, Andrea"]},{"key":"dc:creator","label":"Author","values":["Gingrich Regehr, Alison"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-12-18T20:49:11Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2019-12-18T20:49:11Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2019-12"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2019-12-03"]},{"key":"dc:date.issued","label":"Date","values":["2019-12-18"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["bioretention","evapotranspiration"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10214/17667"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Low impact development practices such as bioretention are being used more frequently in stormwater management. The commonly considered aspects of bioretention are its ability for filtration and infiltration, but evapotranspiration is not frequently considered despite its potential to be a significant component of the water balance. A lysimeter study was conducted in Guelph, Ontario to estimate the ET rate from bioretention facilities. The lysimeter was designed to mimic standard bioretention design parameters. The average annual ET rate was 1.30 mm/d, with monthly averages ranging from -0.009-2.90 mm/d. The lysimeter-derived ET was then compared to ET predicted by the Hamon, Hargreaves-Samani, Jensen-Haise, Penman-Monteith, Priestley-Taylor, and Thorthwaite equations to determine their applicability to use in urban bioretention systems. The Jensen-Haise equation was found to perform the best once a coefficient of 0.5 was applied to consider the protected environment of the lysimeter."]},{"key":"dc:title","label":"Title","values":["Estimation of evapotranspiration from a bioretention facility using a lysimeter and six predictive equations"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Bradford, Andrea"],"dc:creator":["Gingrich Regehr, Alison"],"dc:date.accessioned":["2019-12-18T20:49:11Z"],"dc:date.available":["2019-12-18T20:49:11Z"],"dc:date.copyright":["2019-12"],"dc:date.created":["2019-12-03"],"dc:date.issued":["2019-12-18"],"dc:description.abstract":["Low impact development practices such as bioretention are being used more frequently in stormwater management. The commonly considered aspects of bioretention are its ability for filtration and infiltration, but evapotranspiration is not frequently considered despite its potential to be a significant component of the water balance. A lysimeter study was conducted in Guelph, Ontario to estimate the ET rate from bioretention facilities. The lysimeter was designed to mimic standard bioretention design parameters. The average annual ET rate was 1.30 mm/d, with monthly averages ranging from -0.009-2.90 mm/d. The lysimeter-derived ET was then compared to ET predicted by the Hamon, Hargreaves-Samani, Jensen-Haise, Penman-Monteith, Priestley-Taylor, and Thorthwaite equations to determine their applicability to use in urban bioretention systems. The Jensen-Haise equation was found to perform the best once a coefficient of 0.5 was applied to consider the protected environment of the lysimeter."],"dc:identifier.uri":["http://hdl.handle.net/10214/17667"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["bioretention","evapotranspiration"],"dc:title":["Estimation of evapotranspiration from a bioretention facility using a lysimeter and six predictive equations"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Applied Science"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:25:00Z"}