{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/17710"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/17710","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Performance Degradation of Centrifugal Pump under Single and Variable Speed Operation","abstract":"Centrifugal pumps are widely used in a variety of applications, accounting for approximately 20% of worldwide energy use. Although highly reliable machines, they are not immune to performance degradation over time, experiencing efficiency losses up to 25% by the end of service life. As the pump degrades, operation deviates from the best efficiency point as volumetric, hydraulic and mechanical efficiency decrease. A state-of-the-art experimental setup including a 7.5 kW centrifugal pump rated for a flow rate of 17 L/s and 23 m of head was used. To enable variable speed operation the motor is paired with a variable frequency drive. This thesis investigates and compares the effect of the wear-ring clearance on various operational (head, flow and power) parameters and performance (efficiency and specific speed) parameters under single speed and variable speed operation. The results from this work demonstrates the pump operational reliability under degraded conditions under different control methods.","abstract_html":"Centrifugal pumps are widely used in a variety of applications, accounting for approximately 20% of worldwide energy use. Although highly reliable machines, they are not immune to performance degradation over time, experiencing efficiency losses up to 25% by the end of service life. As the pump degrades, operation deviates from the best efficiency point as volumetric, hydraulic and mechanical efficiency decrease. A state-of-the-art experimental setup including a 7.5 kW centrifugal pump rated for a flow rate of 17 L/s and 23 m of head was used. To enable variable speed operation the motor is paired with a variable frequency drive. This thesis investigates and compares the effect of the wear-ring clearance on various operational (head, flow and power) parameters and performance (efficiency and specific speed) parameters under single speed and variable speed operation. The results from this work demonstrates the pump operational reliability under degraded conditions under different control methods.","abstract_has_math":false,"creators":["D'Alessandro, Fil"],"institution":"University of Guelph","degree_name":"Master of Applied Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Ahmed, Wael","Hassan, Marwan"],"committee_chairs":[],"committee_members":[],"year":2020,"date_issued":"2020-01-03","date_published":"2020-01-03","updated_at":"2026-11-19T08:25:04Z","subjects":["pump","centrifugal Pump","vfd","variable speed drive","variable speed operation","single speed operation","leakage","efficiency","loss","ADT"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/17710","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/17710","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":"embargoed","embargo_until":"2020-12-05","access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F17710","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F17710","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ahmed, Wael","Hassan, Marwan"]},{"key":"dc:creator","label":"Author","values":["D'Alessandro, Fil"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2020-01-03T21:19:01Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2019-12"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2019-12-05"]},{"key":"dc:date.embargo","label":"Dc Date Embargo","values":["2020-12-05"]},{"key":"dc:date.issued","label":"Date","values":["2020-01-03"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["pump","centrifugal Pump","vfd","variable speed drive","variable speed operation","single speed operation","leakage","efficiency","loss","ADT"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10214/17710"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Centrifugal pumps are widely used in a variety of applications, accounting for approximately 20% of worldwide energy use. Although highly reliable machines, they are not immune to performance degradation over time, experiencing efficiency losses up to 25% by the end of service life. As the pump degrades, operation deviates from the best efficiency point as volumetric, hydraulic and mechanical efficiency decrease. A state-of-the-art experimental setup including a 7.5 kW centrifugal pump rated for a flow rate of 17 L/s and 23 m of head was used. To enable variable speed operation the motor is paired with a variable frequency drive. This thesis investigates and compares the effect of the wear-ring clearance on various operational (head, flow and power) parameters and performance (efficiency and specific speed) parameters under single speed and variable speed operation. The results from this work demonstrates the pump operational reliability under degraded conditions under different control methods."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["Natural Sciences and Engineering Research Council of Canada","Xylem Inc."]},{"key":"dc:title","label":"Title","values":["Performance Degradation of Centrifugal Pump under Single and Variable Speed Operation"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Ahmed, Wael","Hassan, Marwan"],"dc:creator":["D'Alessandro, Fil"],"dc:date.accessioned":["2020-01-03T21:19:01Z"],"dc:date.copyright":["2019-12"],"dc:date.created":["2019-12-05"],"dc:date.embargo":["2020-12-05"],"dc:date.issued":["2020-01-03"],"dc:description.abstract":["Centrifugal pumps are widely used in a variety of applications, accounting for approximately 20% of worldwide energy use. Although highly reliable machines, they are not immune to performance degradation over time, experiencing efficiency losses up to 25% by the end of service life. As the pump degrades, operation deviates from the best efficiency point as volumetric, hydraulic and mechanical efficiency decrease. A state-of-the-art experimental setup including a 7.5 kW centrifugal pump rated for a flow rate of 17 L/s and 23 m of head was used. To enable variable speed operation the motor is paired with a variable frequency drive. This thesis investigates and compares the effect of the wear-ring clearance on various operational (head, flow and power) parameters and performance (efficiency and specific speed) parameters under single speed and variable speed operation. The results from this work demonstrates the pump operational reliability under degraded conditions under different control methods."],"dc:description.sponsorship":["Natural Sciences and Engineering Research Council of Canada","Xylem Inc."],"dc:identifier.uri":["http://hdl.handle.net/10214/17710"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["pump","centrifugal Pump","vfd","variable speed drive","variable speed operation","single speed operation","leakage","efficiency","loss","ADT"],"dc:title":["Performance Degradation of Centrifugal Pump under Single and Variable Speed Operation"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Applied Science"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:25:04Z"}