{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/17802"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/17802","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Efficiency of Ozone-Based Advanced Oxidation Processes in Treating Recirculating Irrigation Water","abstract":"The efficacy of using ozone, ultraviolet, and an ozone/UV-based advanced oxidation process (AOP) for the remediation of recycled greenhouse irrigation water was examined. Begonia x heimalis and Gerbera jamesonii were grown for a full crop cycle – no differences were found between the treatments. Lemna minor was used as a bioassay surrogate for vascular plants and cultured in Hoagland’s solution containing various concentrations of glyphosate and paclobutrazol to determine an EC50. Lemna were then cultured in solution drawn from the treatment system reservoirs spiked with the EC50 dose of glyphosate during an irrigation cycle. Recovery of some metrics was observed in O3 and AOP treatments. A dose of 0.78mL L-1 glyphosate was applied to the irrigation reservoirs at the start of a plant growth cycle of Salvia splendens. The systems were not able to protect from the challenge at the rates of herbicide applied.","abstract_html":"The efficacy of using ozone, ultraviolet, and an ozone/UV-based advanced oxidation process (AOP) for the remediation of recycled greenhouse irrigation water was examined. Begonia x heimalis and Gerbera jamesonii were grown for a full crop cycle – no differences were found between the treatments. Lemna minor was used as a bioassay surrogate for vascular plants and cultured in Hoagland’s solution containing various concentrations of glyphosate and paclobutrazol to determine an EC50. Lemna were then cultured in solution drawn from the treatment system reservoirs spiked with the EC50 dose of glyphosate during an irrigation cycle. Recovery of some metrics was observed in O3 and AOP treatments. A dose of 0.78mL L-1 glyphosate was applied to the irrigation reservoirs at the start of a plant growth cycle of Salvia splendens. The systems were not able to protect from the challenge at the rates of herbicide applied.","abstract_has_math":false,"creators":["Bertrand, Brenden"],"institution":"University of Guelph","degree_name":"Master of Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Environmental Sciences","school":null,"contributors":[],"advisors":["Dixon, Mike"],"committee_chairs":[],"committee_members":[],"year":2020,"date_issued":"2020-01-30","date_published":"2020-01-30","updated_at":"2026-11-19T08:26:17Z","subjects":["advanced oxidation process","hydroponics","greenhouse"],"languages":["en"],"rights":["Attribution 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/17802","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/17802","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F17802","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Dixon, Mike"]},{"key":"dc:creator","label":"Author","values":["Bertrand, Brenden"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2020-01-30T18:50:59Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2020-01-30T18:50:59Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2020-01-01"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2019-12-13"]},{"key":"dc:date.issued","label":"Date","values":["2020-01-30"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Environmental Sciences"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Environmental Sciences"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["advanced oxidation process","hydroponics","greenhouse"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution 4.0 International"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://creativecommons.org/licenses/by/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10214/17802"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The efficacy of using ozone, ultraviolet, and an ozone/UV-based advanced oxidation process (AOP) for the remediation of recycled greenhouse irrigation water was examined. Begonia x heimalis and Gerbera jamesonii were grown for a full crop cycle – no differences were found between the treatments. Lemna minor was used as a bioassay surrogate for vascular plants and cultured in Hoagland’s solution containing various concentrations of glyphosate and paclobutrazol to determine an EC50. Lemna were then cultured in solution drawn from the treatment system reservoirs spiked with the EC50 dose of glyphosate during an irrigation cycle. Recovery of some metrics was observed in O3 and AOP treatments. A dose of 0.78mL L-1 glyphosate was applied to the irrigation reservoirs at the start of a plant growth cycle of Salvia splendens. The systems were not able to protect from the challenge at the rates of herbicide applied."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["Greenway Water Treatment","Tersano Inc."]},{"key":"dc:title","label":"Title","values":["Efficiency of Ozone-Based Advanced Oxidation Processes in Treating Recirculating Irrigation Water"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Dixon, Mike"],"dc:creator":["Bertrand, Brenden"],"dc:date.accessioned":["2020-01-30T18:50:59Z"],"dc:date.available":["2020-01-30T18:50:59Z"],"dc:date.copyright":["2020-01-01"],"dc:date.created":["2019-12-13"],"dc:date.issued":["2020-01-30"],"dc:description.abstract":["The efficacy of using ozone, ultraviolet, and an ozone/UV-based advanced oxidation process (AOP) for the remediation of recycled greenhouse irrigation water was examined. Begonia x heimalis and Gerbera jamesonii were grown for a full crop cycle – no differences were found between the treatments. Lemna minor was used as a bioassay surrogate for vascular plants and cultured in Hoagland’s solution containing various concentrations of glyphosate and paclobutrazol to determine an EC50. Lemna were then cultured in solution drawn from the treatment system reservoirs spiked with the EC50 dose of glyphosate during an irrigation cycle. Recovery of some metrics was observed in O3 and AOP treatments. A dose of 0.78mL L-1 glyphosate was applied to the irrigation reservoirs at the start of a plant growth cycle of Salvia splendens. The systems were not able to protect from the challenge at the rates of herbicide applied."],"dc:description.sponsorship":["Greenway Water Treatment","Tersano Inc."],"dc:identifier.uri":["http://hdl.handle.net/10214/17802"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights":["Attribution 4.0 International"],"dc:rights.uri":["http://creativecommons.org/licenses/by/4.0/"],"dc:subject":["advanced oxidation process","hydroponics","greenhouse"],"dc:title":["Efficiency of Ozone-Based Advanced Oxidation Processes in Treating Recirculating Irrigation Water"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Environmental Sciences"],"thesis:degree_name":["Master of Science"],"thesis:degree_program":["Environmental Sciences"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:26:17Z"}