{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/18005"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/18005","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Experimental Investigation of Streamwise Fluidelastic Instability in Tube Arrays","abstract":"Fluidelastic instability (FEI) is a major concern in steam generators and continues to be one of the leading causes of structural failure. There has been a general consensus that the phenomenon of FEI occurs only in the transverse direction rather than in the streamwise direction. After a refurbishment of the San Onofre Nuclear Generation Station (SONGS), there was a failure in the steam generator due to streamwise FEI. This has never been reported before and had traditionally not been considered as a factor in the design of nuclear steam generators. Therefore, research efforts are made to understand this phenomenon. In this work, experiments were conducted using a closed-loop wind tunnel. A fully flexible tube array subjected to cross-flow was considered in the current investigation with pitch to diameter ratios of 1.25, 1.4, 1.55, and 1.7. The tubes were mounted over a flexible support in the direction of the flow.","abstract_html":"Fluidelastic instability (FEI) is a major concern in steam generators and continues to be one of the leading causes of structural failure. There has been a general consensus that the phenomenon of FEI occurs only in the transverse direction rather than in the streamwise direction. After a refurbishment of the San Onofre Nuclear Generation Station (SONGS), there was a failure in the steam generator due to streamwise FEI. This has never been reported before and had traditionally not been considered as a factor in the design of nuclear steam generators. Therefore, research efforts are made to understand this phenomenon. In this work, experiments were conducted using a closed-loop wind tunnel. A fully flexible tube array subjected to cross-flow was considered in the current investigation with pitch to diameter ratios of 1.25, 1.4, 1.55, and 1.7. The tubes were mounted over a flexible support in the direction of the flow.","abstract_has_math":false,"creators":["Aboushita, Ali"],"institution":"University of Guelph","degree_name":"Master of Engineering","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Hassan, Marwan"],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-22T09:34:28Z","subjects":["fluid elasticinstabilty","streamwise fluid elasticinstabilty","vibration measurements","visual image processing","in-plane fluid elasticinstability"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10214/18005","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10214/18005","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":"embargoed","embargo_until":"2021-05-20","access_note":null},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F18005","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Hassan, Marwan"]},{"key":"dc:creator","label":"Author","values":["Aboushita, Ali"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2020-05-28T19:06:54Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2020-05"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2020-05-20"]},{"key":"dc:date.embargo","label":"Dc Date Embargo","values":["2021-05-20"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Engineering"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["fluid elasticinstabilty","streamwise fluid elasticinstabilty","vibration measurements","visual image processing","in-plane fluid elasticinstability"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10214/18005"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Fluidelastic instability (FEI) is a major concern in steam generators and continues to be one of the leading causes of structural failure. There has been a general consensus that the phenomenon of FEI occurs only in the transverse direction rather than in the streamwise direction. After a refurbishment of the San Onofre Nuclear Generation Station (SONGS), there was a failure in the steam generator due to streamwise FEI. This has never been reported before and had traditionally not been considered as a factor in the design of nuclear steam generators. Therefore, research efforts are made to understand this phenomenon. In this work, experiments were conducted using a closed-loop wind tunnel. A fully flexible tube array subjected to cross-flow was considered in the current investigation with pitch to diameter ratios of 1.25, 1.4, 1.55, and 1.7. The tubes were mounted over a flexible support in the direction of the flow."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["Natural Sciences and Engineering Research Council of Canada","Canadian Nuclear Safety Commission"]},{"key":"dc:title","label":"Title","values":["Experimental Investigation of Streamwise Fluidelastic Instability in Tube Arrays"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Hassan, Marwan"],"dc:creator":["Aboushita, Ali"],"dc:date.accessioned":["2020-05-28T19:06:54Z"],"dc:date.copyright":["2020-05"],"dc:date.created":["2020-05-20"],"dc:date.embargo":["2021-05-20"],"dc:description.abstract":["Fluidelastic instability (FEI) is a major concern in steam generators and continues to be one of the leading causes of structural failure. There has been a general consensus that the phenomenon of FEI occurs only in the transverse direction rather than in the streamwise direction. After a refurbishment of the San Onofre Nuclear Generation Station (SONGS), there was a failure in the steam generator due to streamwise FEI. This has never been reported before and had traditionally not been considered as a factor in the design of nuclear steam generators. Therefore, research efforts are made to understand this phenomenon. In this work, experiments were conducted using a closed-loop wind tunnel. A fully flexible tube array subjected to cross-flow was considered in the current investigation with pitch to diameter ratios of 1.25, 1.4, 1.55, and 1.7. The tubes were mounted over a flexible support in the direction of the flow."],"dc:description.sponsorship":["Natural Sciences and Engineering Research Council of Canada","Canadian Nuclear Safety Commission"],"dc:identifier.uri":["http://hdl.handle.net/10214/18005"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["fluid elasticinstabilty","streamwise fluid elasticinstabilty","vibration measurements","visual image processing","in-plane fluid elasticinstability"],"dc:title":["Experimental Investigation of Streamwise Fluidelastic Instability in Tube Arrays"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Engineering"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-22T09:34:28Z"}