{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/21140"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/21140","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Refinement of the GUPIX Treatment of Multiple Ionization Satellites and Detector Non-linearity","abstract":"Wavelength-dispersive spectroscopy was used to obtain the portion of the K X-ray spectra that contained multiple ionization satellites of chlorine, potassium, calcium, titanium and chromium bombarded by alpha particles of energies 3, 4 and 5 MeV. Intense satellites near the diagram line are observed and potential causes are explained. The results differed from the values in an interim database. This second step of database refinement permits the construction of a new database to improve the accuracy of PIXE analysis using alpha particle beams. An iterative method for correcting the detector non-linearity is presented and potential dependencies of the effect are examined using spectra obtained by the alpha particle X-ray spectrometer onboard the Curiosity rover.","abstract_html":"Wavelength-dispersive spectroscopy was used to obtain the portion of the K X-ray spectra that contained multiple ionization satellites of chlorine, potassium, calcium, titanium and chromium bombarded by alpha particles of energies 3, 4 and 5 MeV. Intense satellites near the diagram line are observed and potential causes are explained. The results differed from the values in an interim database. This second step of database refinement permits the construction of a new database to improve the accuracy of PIXE analysis using alpha particle beams. An iterative method for correcting the detector non-linearity is presented and potential dependencies of the effect are examined using spectra obtained by the alpha particle X-ray spectrometer onboard the Curiosity rover.","abstract_has_math":false,"creators":["Cureatz, Daniel"],"institution":"University of Guelph","degree_name":"Master of Science","degree_level":null,"degree_discipline":null,"degree_department":"Department of Physics","school":null,"contributors":[],"advisors":["Campbell, John L. (Iain)","O'Meara, Joanne"],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-22T09:34:17Z","subjects":["GUPIX","multiple ionization satellites","PIXE","detector non-linearity","x-ray","alpha-pixe"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/21140","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/21140","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F21140","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F21140","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Campbell, John L. (Iain)","O'Meara, Joanne"]},{"key":"dc:creator","label":"Author","values":["Cureatz, Daniel"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2020-08-31T13:55:09Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2020-08-31T13:55:09Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2020-08"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2020-08-26"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Department of Physics"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["GUPIX","multiple ionization satellites","PIXE","detector non-linearity","x-ray","alpha-pixe"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10214/21140"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Wavelength-dispersive spectroscopy was used to obtain the portion of the K X-ray spectra that contained multiple ionization satellites of chlorine, potassium, calcium, titanium and chromium bombarded by alpha particles of energies 3, 4 and 5 MeV. Intense satellites near the diagram line are observed and potential causes are explained. The results differed from the values in an interim database. This second step of database refinement permits the construction of a new database to improve the accuracy of PIXE analysis using alpha particle beams. An iterative method for correcting the detector non-linearity is presented and potential dependencies of the effect are examined using spectra obtained by the alpha particle X-ray spectrometer onboard the Curiosity rover."]},{"key":"dc:title","label":"Title","values":["Refinement of the GUPIX Treatment of Multiple Ionization Satellites and Detector Non-linearity"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Campbell, John L. (Iain)","O'Meara, Joanne"],"dc:creator":["Cureatz, Daniel"],"dc:date.accessioned":["2020-08-31T13:55:09Z"],"dc:date.available":["2020-08-31T13:55:09Z"],"dc:date.copyright":["2020-08"],"dc:date.created":["2020-08-26"],"dc:description.abstract":["Wavelength-dispersive spectroscopy was used to obtain the portion of the K X-ray spectra that contained multiple ionization satellites of chlorine, potassium, calcium, titanium and chromium bombarded by alpha particles of energies 3, 4 and 5 MeV. Intense satellites near the diagram line are observed and potential causes are explained. The results differed from the values in an interim database. This second step of database refinement permits the construction of a new database to improve the accuracy of PIXE analysis using alpha particle beams. An iterative method for correcting the detector non-linearity is presented and potential dependencies of the effect are examined using spectra obtained by the alpha particle X-ray spectrometer onboard the Curiosity rover."],"dc:identifier.uri":["https://hdl.handle.net/10214/21140"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["GUPIX","multiple ionization satellites","PIXE","detector non-linearity","x-ray","alpha-pixe"],"dc:title":["Refinement of the GUPIX Treatment of Multiple Ionization Satellites and Detector Non-linearity"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["Department of Physics"],"thesis:degree_name":["Master of Science"],"thesis:degree_program":["Physics"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-22T09:34:17Z"}