{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/23713"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/23713","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Designing and Commissioning of a Prototype High Energy Resolution Fluorescence Detection System at the Canadian Light Source","abstract":"This thesis can be viewed as a feasibility study into running a High Energy Resolution Fluorescence Detection system for x-ray absorption spectroscopy at the Hard X-ray MicroAnalysis beamline at the Canadian Light Source. This study was carried out through the construction of an x-ray photon energy analyzer system based around a single Johann crystal on a Rowland circle with a half meter diameter. Using this system high resolution scans of cinnabar (HgS-α) and metacinnabar (HgS-β) were collected and compared to conventional fluorescence results. A dramatic increase in spectral sharpness was observed showing the validity and capability of this technique. The results attained are comparable to results acquired at other synchrotron facilities using a variety of x-ray sources and beamline optics. Further testing and refinement at HXMA is expected to progress this technique to a user operable state. Ideally this is work is just the first steps in making High Energy Resolution Fluorescence detection available in Canada.","abstract_html":"This thesis can be viewed as a feasibility study into running a High Energy Resolution Fluorescence Detection system for x-ray absorption spectroscopy at the Hard X-ray MicroAnalysis beamline at the Canadian Light Source. This study was carried out through the construction of an x-ray photon energy analyzer system based around a single Johann crystal on a Rowland circle with a half meter diameter. Using this system high resolution scans of cinnabar (HgS-α) and metacinnabar (HgS-β) were collected and compared to conventional fluorescence results. A dramatic increase in spectral sharpness was observed showing the validity and capability of this technique. The results attained are comparable to results acquired at other synchrotron facilities using a variety of x-ray sources and beamline optics. Further testing and refinement at HXMA is expected to progress this technique to a user operable state. Ideally this is work is just the first steps in making High Energy Resolution Fluorescence detection available in Canada.","abstract_has_math":false,"creators":["Thomas, Evan"],"institution":"University of Guelph","degree_name":"Master of Science","degree_level":null,"degree_discipline":null,"degree_department":"Department of Physics","school":null,"contributors":[],"advisors":["Jiang, De-Tong"],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:22:07Z","subjects":["XAFS","HERFD"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/23713","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/23713","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F23713","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F23713","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Jiang, De-Tong"]},{"key":"dc:creator","label":"Author","values":["Thomas, Evan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2021-01-08T19:37:23Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2021-01-08T19:37:23Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2021-12"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2020-12-15"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Department of Physics"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["XAFS","HERFD"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10214/23713"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis can be viewed as a feasibility study into running a High Energy Resolution Fluorescence Detection system for x-ray absorption spectroscopy at the Hard X-ray MicroAnalysis beamline at the Canadian Light Source. This study was carried out through the construction of an x-ray photon energy analyzer system based around a single Johann crystal on a Rowland circle with a half meter diameter. Using this system high resolution scans of cinnabar (HgS-α) and metacinnabar (HgS-β) were collected and compared to conventional fluorescence results. A dramatic increase in spectral sharpness was observed showing the validity and capability of this technique. The results attained are comparable to results acquired at other synchrotron facilities using a variety of x-ray sources and beamline optics. Further testing and refinement at HXMA is expected to progress this technique to a user operable state. Ideally this is work is just the first steps in making High Energy Resolution Fluorescence detection available in Canada."]},{"key":"dc:title","label":"Title","values":["Designing and Commissioning of a Prototype High Energy Resolution Fluorescence Detection System at the Canadian Light Source"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Jiang, De-Tong"],"dc:creator":["Thomas, Evan"],"dc:date.accessioned":["2021-01-08T19:37:23Z"],"dc:date.available":["2021-01-08T19:37:23Z"],"dc:date.copyright":["2021-12"],"dc:date.created":["2020-12-15"],"dc:description.abstract":["This thesis can be viewed as a feasibility study into running a High Energy Resolution Fluorescence Detection system for x-ray absorption spectroscopy at the Hard X-ray MicroAnalysis beamline at the Canadian Light Source. This study was carried out through the construction of an x-ray photon energy analyzer system based around a single Johann crystal on a Rowland circle with a half meter diameter. Using this system high resolution scans of cinnabar (HgS-α) and metacinnabar (HgS-β) were collected and compared to conventional fluorescence results. A dramatic increase in spectral sharpness was observed showing the validity and capability of this technique. The results attained are comparable to results acquired at other synchrotron facilities using a variety of x-ray sources and beamline optics. Further testing and refinement at HXMA is expected to progress this technique to a user operable state. Ideally this is work is just the first steps in making High Energy Resolution Fluorescence detection available in Canada."],"dc:identifier.uri":["https://hdl.handle.net/10214/23713"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["XAFS","HERFD"],"dc:title":["Designing and Commissioning of a Prototype High Energy Resolution Fluorescence Detection System at the Canadian Light Source"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["Department of Physics"],"thesis:degree_name":["Master of Science"],"thesis:degree_program":["Physics"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:22:07Z"}