{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/25701"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/25701","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Streamwise Fluidelastic Instability in Parallel Triangular Tube Arrays","abstract":"Fluidelastic instability is a major contributor to the failures of nuclear steam generators. This work aims to enhance the current understanding of the excitation mechanism with special attention paid to the streamwise fluidelastic instability. A two-phase flow loop was designed and built to facilitate the study of flow-induced vibrations within tube bundles in support of the nuclear industry. This thesis reports on the commissioning of the flow loop, as well as preliminary single-phase results important to validating results from the loop. A study of fluidelastic instability was conducted within a parallel triangular tube array with a pitch-to-diameter ratio of 1.48 subjected to single-phase liquid cross flow. The critical velocity of fluidelastic instability, as well as the stabilizing effect of AVBs on both the transverse and streamwise tube motion, were in good agreement with other data in the literature.","abstract_html":"Fluidelastic instability is a major contributor to the failures of nuclear steam generators. This work aims to enhance the current understanding of the excitation mechanism with special attention paid to the streamwise fluidelastic instability. A two-phase flow loop was designed and built to facilitate the study of flow-induced vibrations within tube bundles in support of the nuclear industry. This thesis reports on the commissioning of the flow loop, as well as preliminary single-phase results important to validating results from the loop. A study of fluidelastic instability was conducted within a parallel triangular tube array with a pitch-to-diameter ratio of 1.48 subjected to single-phase liquid cross flow. The critical velocity of fluidelastic instability, as well as the stabilizing effect of AVBs on both the transverse and streamwise tube motion, were in good agreement with other data in the literature.","abstract_has_math":false,"creators":["Pitfield, Graham"],"institution":"University of Guelph","degree_name":"Master of Applied Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Hassan, Marwan"],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:26:09Z","subjects":["fluidelastic instability","flow induced vibrations","streamwise","tube array","vibrations"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/25701","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/25701","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F25701","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Hassan, Marwan"]},{"key":"dc:creator","label":"Author","values":["Pitfield, Graham"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2021-05-11T17:45:53Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2021-05-11T17:45:53Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2021-05"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2021-04-19"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["fluidelastic instability","flow induced vibrations","streamwise","tube array","vibrations"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10214/25701"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Fluidelastic instability is a major contributor to the failures of nuclear steam generators. This work aims to enhance the current understanding of the excitation mechanism with special attention paid to the streamwise fluidelastic instability. A two-phase flow loop was designed and built to facilitate the study of flow-induced vibrations within tube bundles in support of the nuclear industry. This thesis reports on the commissioning of the flow loop, as well as preliminary single-phase results important to validating results from the loop. A study of fluidelastic instability was conducted within a parallel triangular tube array with a pitch-to-diameter ratio of 1.48 subjected to single-phase liquid cross flow. The critical velocity of fluidelastic instability, as well as the stabilizing effect of AVBs on both the transverse and streamwise tube motion, were in good agreement with other data in the literature."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["Canadian Nuclear Safety Commission"]},{"key":"dc:title","label":"Title","values":["Streamwise Fluidelastic Instability in Parallel Triangular Tube Arrays"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Hassan, Marwan"],"dc:creator":["Pitfield, Graham"],"dc:date.accessioned":["2021-05-11T17:45:53Z"],"dc:date.available":["2021-05-11T17:45:53Z"],"dc:date.copyright":["2021-05"],"dc:date.created":["2021-04-19"],"dc:description.abstract":["Fluidelastic instability is a major contributor to the failures of nuclear steam generators. This work aims to enhance the current understanding of the excitation mechanism with special attention paid to the streamwise fluidelastic instability. A two-phase flow loop was designed and built to facilitate the study of flow-induced vibrations within tube bundles in support of the nuclear industry. This thesis reports on the commissioning of the flow loop, as well as preliminary single-phase results important to validating results from the loop. A study of fluidelastic instability was conducted within a parallel triangular tube array with a pitch-to-diameter ratio of 1.48 subjected to single-phase liquid cross flow. The critical velocity of fluidelastic instability, as well as the stabilizing effect of AVBs on both the transverse and streamwise tube motion, were in good agreement with other data in the literature."],"dc:description.sponsorship":["Canadian Nuclear Safety Commission"],"dc:identifier.uri":["https://hdl.handle.net/10214/25701"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["fluidelastic instability","flow induced vibrations","streamwise","tube array","vibrations"],"dc:title":["Streamwise Fluidelastic Instability in Parallel Triangular Tube Arrays"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Applied Science"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:26:09Z"}