{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/25702"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/25702","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Innovative Application of Electroflotation Technology for Microbrewery Wastewater Treatment","abstract":"Decentralized wastewater generators are experiencing increasing pressure from rising overstrength surcharge fees to identify more economical and sustainable methods of disposing of the wastewater. A continuous lab-scale electroflotation reactor was designed for the treatment of high-strength microbrewery wastewater (MBWW). MBWW has extremely elevated levels of total suspended solids (TSS) (>6000 mg/L), chemical oxygen demand (COD) (10,000 mg/L) and total phosphorous (TP) (300 mg/L). As a result, it is notoriously challenging to treat using conventional onsite treatment methods, particularly due to the dynamic and complex composition of the wastewater matrix. With an applied current density of 8 A/m2 and an electroflotation treatment time of just 20 minutes, the electroflotation reactor was able to effectively remove >95 % of TSS, >85% of TP, and >70% of COD. The results presented in this thesis highlight the potential for the electroflotation reactor to be integrated alongside pre-existing systems or to operate as a standalone advanced treatment unit.","abstract_html":"Decentralized wastewater generators are experiencing increasing pressure from rising overstrength surcharge fees to identify more economical and sustainable methods of disposing of the wastewater. A continuous lab-scale electroflotation reactor was designed for the treatment of high-strength microbrewery wastewater (MBWW). MBWW has extremely elevated levels of total suspended solids (TSS) (&gt;6000 mg/L), chemical oxygen demand (COD) (10,000 mg/L) and total phosphorous (TP) (300 mg/L). As a result, it is notoriously challenging to treat using conventional onsite treatment methods, particularly due to the dynamic and complex composition of the wastewater matrix. With an applied current density of 8 A/m2 and an electroflotation treatment time of just 20 minutes, the electroflotation reactor was able to effectively remove &gt;95 % of TSS, &gt;85% of TP, and &gt;70% of COD. The results presented in this thesis highlight the potential for the electroflotation reactor to be integrated alongside pre-existing systems or to operate as a standalone advanced treatment unit.","abstract_has_math":false,"creators":["Arambarri, James"],"institution":"University of Guelph","degree_name":"Master of Applied Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Abbassi, Bassim"],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:25:24Z","subjects":["electroflotation","wastewater treatment","decentralized","continuous","electric field","electrolysis","electrochemical","flotation","solids separation","microbrewery"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/25702","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/25702","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":"embargoed","embargo_until":"2022-04-13","access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F25702","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F25702","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Abbassi, Bassim"]},{"key":"dc:creator","label":"Author","values":["Arambarri, James"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2021-05-11T18:26:04Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2021-05"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2021-04-13"]},{"key":"dc:date.embargo","label":"Dc Date Embargo","values":["2022-04-13"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["electroflotation","wastewater treatment","decentralized","continuous","electric field","electrolysis","electrochemical","flotation","solids separation","microbrewery"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10214/25702"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Decentralized wastewater generators are experiencing increasing pressure from rising overstrength surcharge fees to identify more economical and sustainable methods of disposing of the wastewater. A continuous lab-scale electroflotation reactor was designed for the treatment of high-strength microbrewery wastewater (MBWW). MBWW has extremely elevated levels of total suspended solids (TSS) (>6000 mg/L), chemical oxygen demand (COD) (10,000 mg/L) and total phosphorous (TP) (300 mg/L). As a result, it is notoriously challenging to treat using conventional onsite treatment methods, particularly due to the dynamic and complex composition of the wastewater matrix. With an applied current density of 8 A/m2 and an electroflotation treatment time of just 20 minutes, the electroflotation reactor was able to effectively remove >95 % of TSS, >85% of TP, and >70% of COD. The results presented in this thesis highlight the potential for the electroflotation reactor to be integrated alongside pre-existing systems or to operate as a standalone advanced treatment unit."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["Ontario Ministry of Agriculture, Food and Rural Affairs"]},{"key":"dc:title","label":"Title","values":["Innovative Application of Electroflotation Technology for Microbrewery Wastewater Treatment"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Abbassi, Bassim"],"dc:creator":["Arambarri, James"],"dc:date.accessioned":["2021-05-11T18:26:04Z"],"dc:date.copyright":["2021-05"],"dc:date.created":["2021-04-13"],"dc:date.embargo":["2022-04-13"],"dc:description.abstract":["Decentralized wastewater generators are experiencing increasing pressure from rising overstrength surcharge fees to identify more economical and sustainable methods of disposing of the wastewater. A continuous lab-scale electroflotation reactor was designed for the treatment of high-strength microbrewery wastewater (MBWW). MBWW has extremely elevated levels of total suspended solids (TSS) (>6000 mg/L), chemical oxygen demand (COD) (10,000 mg/L) and total phosphorous (TP) (300 mg/L). As a result, it is notoriously challenging to treat using conventional onsite treatment methods, particularly due to the dynamic and complex composition of the wastewater matrix. With an applied current density of 8 A/m2 and an electroflotation treatment time of just 20 minutes, the electroflotation reactor was able to effectively remove >95 % of TSS, >85% of TP, and >70% of COD. The results presented in this thesis highlight the potential for the electroflotation reactor to be integrated alongside pre-existing systems or to operate as a standalone advanced treatment unit."],"dc:description.sponsorship":["Ontario Ministry of Agriculture, Food and Rural Affairs"],"dc:identifier.uri":["https://hdl.handle.net/10214/25702"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["electroflotation","wastewater treatment","decentralized","continuous","electric field","electrolysis","electrochemical","flotation","solids separation","microbrewery"],"dc:title":["Innovative Application of Electroflotation Technology for Microbrewery Wastewater Treatment"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Applied Science"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:25:24Z"}