{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/25715"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/25715","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Electrolysis Catalyzed Ozonation as an Advanced Oxidation Process for Wastewater Treatment","abstract":"The prohibitive cost of advanced oxidation processes (AOPs) necessitates the development of innovative variations to increase their applicability. This investigation evaluated the combination of ozonation and electrolysis using iron electrodes, as a catalytic ozonation AOP for the mineralization of organic compounds. The operating parameters of initial pH and current density were optimized to maximize TOC removal, using response surface methodology. Under optimal conditions of 12 mA/cm2 and an initial pH of 9, 63% TOC removal was achieved after 60 minutes of treatment. A comparison of chemical and electrochemical catalyst dosage revealed that the electrochemical method was more effective from the perspective of TOC removal. Using an indirect detection method involving tertiary butyl alcohol, the presence of hydroxyl radicals was detected and identified as the primary oxidizing species responsible for TOC removal. Overall, the performance of this treatment method was successfully demonstrated as an AOP for wastewater treatment.","abstract_html":"The prohibitive cost of advanced oxidation processes (AOPs) necessitates the development of innovative variations to increase their applicability. This investigation evaluated the combination of ozonation and electrolysis using iron electrodes, as a catalytic ozonation AOP for the mineralization of organic compounds. The operating parameters of initial pH and current density were optimized to maximize TOC removal, using response surface methodology. Under optimal conditions of 12 mA/cm2 and an initial pH of 9, 63% TOC removal was achieved after 60 minutes of treatment. A comparison of chemical and electrochemical catalyst dosage revealed that the electrochemical method was more effective from the perspective of TOC removal. Using an indirect detection method involving tertiary butyl alcohol, the presence of hydroxyl radicals was detected and identified as the primary oxidizing species responsible for TOC removal. Overall, the performance of this treatment method was successfully demonstrated as an AOP for wastewater treatment.","abstract_has_math":false,"creators":["Heebner, Anthony"],"institution":"University of Guelph","degree_name":"Master of Applied Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Abbassi, Bassim"],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:26:04Z","subjects":["ozonation","advanced oxidation","wastewater treatment","electrolysis","electrocoagulation","catalytic ozonation","organic contaminants","dairy processing wastewater","catalysis","advanced oxidation process","ozone"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/25715","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/25715","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F25715","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F25715","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Abbassi, Bassim"]},{"key":"dc:creator","label":"Author","values":["Heebner, Anthony"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2021-05-12T15:11:20Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2021-05-12T15:11:20Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2021"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2021-04-21"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["ozonation","advanced oxidation","wastewater treatment","electrolysis","electrocoagulation","catalytic ozonation","organic contaminants","dairy processing wastewater","catalysis","advanced oxidation process","ozone"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10214/25715"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The prohibitive cost of advanced oxidation processes (AOPs) necessitates the development of innovative variations to increase their applicability. This investigation evaluated the combination of ozonation and electrolysis using iron electrodes, as a catalytic ozonation AOP for the mineralization of organic compounds. The operating parameters of initial pH and current density were optimized to maximize TOC removal, using response surface methodology. Under optimal conditions of 12 mA/cm2 and an initial pH of 9, 63% TOC removal was achieved after 60 minutes of treatment. A comparison of chemical and electrochemical catalyst dosage revealed that the electrochemical method was more effective from the perspective of TOC removal. Using an indirect detection method involving tertiary butyl alcohol, the presence of hydroxyl radicals was detected and identified as the primary oxidizing species responsible for TOC removal. Overall, the performance of this treatment method was successfully demonstrated as an AOP for wastewater treatment."]},{"key":"dc:title","label":"Title","values":["Electrolysis Catalyzed Ozonation as an Advanced Oxidation Process for Wastewater Treatment"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Abbassi, Bassim"],"dc:creator":["Heebner, Anthony"],"dc:date.accessioned":["2021-05-12T15:11:20Z"],"dc:date.available":["2021-05-12T15:11:20Z"],"dc:date.copyright":["2021"],"dc:date.created":["2021-04-21"],"dc:description.abstract":["The prohibitive cost of advanced oxidation processes (AOPs) necessitates the development of innovative variations to increase their applicability. This investigation evaluated the combination of ozonation and electrolysis using iron electrodes, as a catalytic ozonation AOP for the mineralization of organic compounds. The operating parameters of initial pH and current density were optimized to maximize TOC removal, using response surface methodology. Under optimal conditions of 12 mA/cm2 and an initial pH of 9, 63% TOC removal was achieved after 60 minutes of treatment. A comparison of chemical and electrochemical catalyst dosage revealed that the electrochemical method was more effective from the perspective of TOC removal. Using an indirect detection method involving tertiary butyl alcohol, the presence of hydroxyl radicals was detected and identified as the primary oxidizing species responsible for TOC removal. Overall, the performance of this treatment method was successfully demonstrated as an AOP for wastewater treatment."],"dc:identifier.uri":["https://hdl.handle.net/10214/25715"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["ozonation","advanced oxidation","wastewater treatment","electrolysis","electrocoagulation","catalytic ozonation","organic contaminants","dairy processing wastewater","catalysis","advanced oxidation process","ozone"],"dc:title":["Electrolysis Catalyzed Ozonation as an Advanced Oxidation Process for Wastewater Treatment"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Applied Science"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:26:04Z"}