{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/25738"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/25738","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Melting and solidification of PCM and PCM-expanded graphite composite using toroidal tube heat exchanges","abstract":"In the current study, melting and solidification of phase change materials (PCMs) with added expanded graphite (EG) are studied for two novel toroidal tube heat exchanger geometries. COMSOL Multiphysics® is used for numerical simulation, and in total, 118 cases have been investigated. The thermal performance is evaluated in terms of (i) melt/solid fraction, (ii) energy stored/released by PCM/CPCM, (iii) average PCM/CPCM temperature, and (iv) heat flux. The effects of heat exchanger geometric parameters such as tube turn (n), pitch controller (m), tube layers, type of PCMs, and fin configurations on mentioned parameters are studied. Result suggests that using PCM impregnated EG in the single-layer toroidal tube geometry, (i) reduces melting time by 97.42%, (ii) increases the energy storage rate by 1944.25%, and (iii) reduces the thermal equilibrium time by 97.70%. The use of multiple PCM in the toroidal tube heat exchanger can be evaluated in the future.","abstract_html":"In the current study, melting and solidification of phase change materials (PCMs) with added expanded graphite (EG) are studied for two novel toroidal tube heat exchanger geometries. COMSOL Multiphysics® is used for numerical simulation, and in total, 118 cases have been investigated. The thermal performance is evaluated in terms of (i) melt/solid fraction, (ii) energy stored/released by PCM/CPCM, (iii) average PCM/CPCM temperature, and (iv) heat flux. The effects of heat exchanger geometric parameters such as tube turn (n), pitch controller (m), tube layers, type of PCMs, and fin configurations on mentioned parameters are studied. Result suggests that using PCM impregnated EG in the single-layer toroidal tube geometry, (i) reduces melting time by 97.42%, (ii) increases the energy storage rate by 1944.25%, and (iii) reduces the thermal equilibrium time by 97.70%. The use of multiple PCM in the toroidal tube heat exchanger can be evaluated in the future.","abstract_has_math":false,"creators":["Patel, Sunnykumar"],"institution":"University of Guelph","degree_name":"Master of Applied Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Tasnim, Syeda Humaira"],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:27:30Z","subjects":["latent heat thermal energy storage (LHTES)","expanded graphite (EG)","phase change material (PCM)","heat exchanger","toroidal tube","melting and solidification"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/25738","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/25738","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":"embargoed","embargo_until":"2022-05-10","access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F25738","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F25738","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Tasnim, Syeda Humaira"]},{"key":"dc:creator","label":"Author","values":["Patel, Sunnykumar"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2021-05-17T14:36:26Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2021-05-10"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2021-05-10"]},{"key":"dc:date.embargo","label":"Dc Date Embargo","values":["2022-05-10"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["latent heat thermal energy storage (LHTES)","expanded graphite (EG)","phase change material (PCM)","heat exchanger","toroidal tube","melting and solidification"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10214/25738"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In the current study, melting and solidification of phase change materials (PCMs) with added expanded graphite (EG) are studied for two novel toroidal tube heat exchanger geometries. COMSOL Multiphysics® is used for numerical simulation, and in total, 118 cases have been investigated. The thermal performance is evaluated in terms of (i) melt/solid fraction, (ii) energy stored/released by PCM/CPCM, (iii) average PCM/CPCM temperature, and (iv) heat flux. The effects of heat exchanger geometric parameters such as tube turn (n), pitch controller (m), tube layers, type of PCMs, and fin configurations on mentioned parameters are studied. Result suggests that using PCM impregnated EG in the single-layer toroidal tube geometry, (i) reduces melting time by 97.42%, (ii) increases the energy storage rate by 1944.25%, and (iii) reduces the thermal equilibrium time by 97.70%. The use of multiple PCM in the toroidal tube heat exchanger can be evaluated in the future."]},{"key":"dc:title","label":"Title","values":["Melting and solidification of PCM and PCM-expanded graphite composite using toroidal tube heat exchanges"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Tasnim, Syeda Humaira"],"dc:creator":["Patel, Sunnykumar"],"dc:date.accessioned":["2021-05-17T14:36:26Z"],"dc:date.copyright":["2021-05-10"],"dc:date.created":["2021-05-10"],"dc:date.embargo":["2022-05-10"],"dc:description.abstract":["In the current study, melting and solidification of phase change materials (PCMs) with added expanded graphite (EG) are studied for two novel toroidal tube heat exchanger geometries. COMSOL Multiphysics® is used for numerical simulation, and in total, 118 cases have been investigated. The thermal performance is evaluated in terms of (i) melt/solid fraction, (ii) energy stored/released by PCM/CPCM, (iii) average PCM/CPCM temperature, and (iv) heat flux. The effects of heat exchanger geometric parameters such as tube turn (n), pitch controller (m), tube layers, type of PCMs, and fin configurations on mentioned parameters are studied. Result suggests that using PCM impregnated EG in the single-layer toroidal tube geometry, (i) reduces melting time by 97.42%, (ii) increases the energy storage rate by 1944.25%, and (iii) reduces the thermal equilibrium time by 97.70%. The use of multiple PCM in the toroidal tube heat exchanger can be evaluated in the future."],"dc:identifier.uri":["https://hdl.handle.net/10214/25738"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["latent heat thermal energy storage (LHTES)","expanded graphite (EG)","phase change material (PCM)","heat exchanger","toroidal tube","melting and solidification"],"dc:title":["Melting and solidification of PCM and PCM-expanded graphite composite using toroidal tube heat exchanges"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Applied Science"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:27:30Z"}