{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/25758"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/25758","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Improving the Performance of Airlift Pumps Operating at Low Submergence Ratios","abstract":"Airlift pumps are designed to simultaneously move and oxygenate water. In recent years, their sustainable operation allowed them to gain popularity in the aquaculture and food industries. Improving the performance of airlift pumps at low submergence ratios could broaden their applications to industries like vertical farming. This thesis presents a comprehensive experimental investigation of a dual-injector airlift pump to improve performance and aeration capabilities for low submergence ratios. Oxygenation experiments found that the radial injector provided improved aeration at low airflow rates, while the axial injector had better aeration at high airflow rates. Further analysis suggested that pulsating injection methods could substantially improve performance. Experiments conducted at various injection modes and frequencies found that pulsation improved the efficiency of the pump, particularly at lower submergence ratios. This research is a step towards improving the design guidelines of airlift pumps, expanding their operational capabilities for the benefits of vertical farming applications.","abstract_html":"Airlift pumps are designed to simultaneously move and oxygenate water. In recent years, their sustainable operation allowed them to gain popularity in the aquaculture and food industries. Improving the performance of airlift pumps at low submergence ratios could broaden their applications to industries like vertical farming. This thesis presents a comprehensive experimental investigation of a dual-injector airlift pump to improve performance and aeration capabilities for low submergence ratios. Oxygenation experiments found that the radial injector provided improved aeration at low airflow rates, while the axial injector had better aeration at high airflow rates. Further analysis suggested that pulsating injection methods could substantially improve performance. Experiments conducted at various injection modes and frequencies found that pulsation improved the efficiency of the pump, particularly at lower submergence ratios. This research is a step towards improving the design guidelines of airlift pumps, expanding their operational capabilities for the benefits of vertical farming applications.","abstract_has_math":false,"creators":["Abed, Rashal"],"institution":"University of Guelph","degree_name":"Master of Applied Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Ahmed, Wael"],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:27:51Z","subjects":["airlift pump","multiphase flow","two-phase flow","submergence ratio","oxygenation","dual-injection","pulsation","non-developing flow","void fraction"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/25758","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/25758","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":"embargoed","embargo_until":"2022-05-04","access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F25758","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F25758","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ahmed, Wael"]},{"key":"dc:creator","label":"Author","values":["Abed, Rashal"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2021-05-19T14:26:29Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2021-03"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2021-05-04"]},{"key":"dc:date.embargo","label":"Dc Date Embargo","values":["2022-05-04"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["airlift pump","multiphase flow","two-phase flow","submergence ratio","oxygenation","dual-injection","pulsation","non-developing flow","void fraction"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10214/25758"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Airlift pumps are designed to simultaneously move and oxygenate water. In recent years, their sustainable operation allowed them to gain popularity in the aquaculture and food industries. Improving the performance of airlift pumps at low submergence ratios could broaden their applications to industries like vertical farming. This thesis presents a comprehensive experimental investigation of a dual-injector airlift pump to improve performance and aeration capabilities for low submergence ratios. Oxygenation experiments found that the radial injector provided improved aeration at low airflow rates, while the axial injector had better aeration at high airflow rates. Further analysis suggested that pulsating injection methods could substantially improve performance. Experiments conducted at various injection modes and frequencies found that pulsation improved the efficiency of the pump, particularly at lower submergence ratios. This research is a step towards improving the design guidelines of airlift pumps, expanding their operational capabilities for the benefits of vertical farming applications."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["Ontario Ministry of Agriculture, Food and Rural Affairs"]},{"key":"dc:title","label":"Title","values":["Improving the Performance of Airlift Pumps Operating at Low Submergence Ratios"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Ahmed, Wael"],"dc:creator":["Abed, Rashal"],"dc:date.accessioned":["2021-05-19T14:26:29Z"],"dc:date.copyright":["2021-03"],"dc:date.created":["2021-05-04"],"dc:date.embargo":["2022-05-04"],"dc:description.abstract":["Airlift pumps are designed to simultaneously move and oxygenate water. In recent years, their sustainable operation allowed them to gain popularity in the aquaculture and food industries. Improving the performance of airlift pumps at low submergence ratios could broaden their applications to industries like vertical farming. This thesis presents a comprehensive experimental investigation of a dual-injector airlift pump to improve performance and aeration capabilities for low submergence ratios. Oxygenation experiments found that the radial injector provided improved aeration at low airflow rates, while the axial injector had better aeration at high airflow rates. Further analysis suggested that pulsating injection methods could substantially improve performance. Experiments conducted at various injection modes and frequencies found that pulsation improved the efficiency of the pump, particularly at lower submergence ratios. This research is a step towards improving the design guidelines of airlift pumps, expanding their operational capabilities for the benefits of vertical farming applications."],"dc:description.sponsorship":["Ontario Ministry of Agriculture, Food and Rural Affairs"],"dc:identifier.uri":["https://hdl.handle.net/10214/25758"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["airlift pump","multiphase flow","two-phase flow","submergence ratio","oxygenation","dual-injection","pulsation","non-developing flow","void fraction"],"dc:title":["Improving the Performance of Airlift Pumps Operating at Low Submergence Ratios"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Applied Science"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:27:51Z"}