{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/26316"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/26316","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Canine Femoral Deformities Causing Medial Patellar Luxation Characterized And Corrected Using Computed Tomography And Three-Dimensional Printing Technology","abstract":"Our objectives were to validate a protocol for evaluating femoral alignment in dogs with MPL using CT and use it to design and report the accuracy and repeatability of a 3D-printed DFWO guide and plate system. The angles evaluated were aLDFA including FVA, FCT, AA, IA and NAA. Repeatability for all measurements ranged from moderate (ICC = 0.65) to excellent (ICC = 0.96). Reliability ranged from good (ICC = 0.79) to excellent (ICC = 0.99). Seven femurs had varus/valgus (aLDFA) corrected to 95° and torsion (AA) corrected to 30°. The mean difference between the target and achieved was 1.29° (+/-3.58°, p = .085) for aLDFA and 3.43° (+/-5.21°, p = .012) for AA. The intraobserver ICCs for aLDFA and AA were 0.865 and 0.817, respectively. The measurement protocol was repeatable and reliable and the DFWO system provided accurate and repeatable correction of frontal plane deformities but not torsional deformities.","abstract_html":"Our objectives were to validate a protocol for evaluating femoral alignment in dogs with MPL using CT and use it to design and report the accuracy and repeatability of a 3D-printed DFWO guide and plate system. The angles evaluated were aLDFA including FVA, FCT, AA, IA and NAA. Repeatability for all measurements ranged from moderate (ICC = 0.65) to excellent (ICC = 0.96). Reliability ranged from good (ICC = 0.79) to excellent (ICC = 0.99). Seven femurs had varus/valgus (aLDFA) corrected to 95° and torsion (AA) corrected to 30°. The mean difference between the target and achieved was 1.29° (+/-3.58°, p = .085) for aLDFA and 3.43° (+/-5.21°, p = .012) for AA. The intraobserver ICCs for aLDFA and AA were 0.865 and 0.817, respectively. The measurement protocol was repeatable and reliable and the DFWO system provided accurate and repeatable correction of frontal plane deformities but not torsional deformities.","abstract_has_math":false,"creators":["Iannitelli, Bianca"],"institution":"University of Guelph","degree_name":"Master of Science","degree_level":null,"degree_discipline":null,"degree_department":"Department of Clinical Studies","school":null,"contributors":[],"advisors":["Moens, Noel","Oblak, Michelle"],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:23:25Z","subjects":["medial patellar luxation","angular limb deformity","3D-printing","patient-specific guides","computed tomography","patient-specific implants","femoral varus"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/26316","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/26316","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F26316","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Moens, Noel","Oblak, Michelle"]},{"key":"dc:creator","label":"Author","values":["Iannitelli, Bianca"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2021-08-27T20:06:30Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2021-08-27T20:06:30Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2021-08"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2021-06-09"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Department of Clinical Studies"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Clinical Studies"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["medial patellar luxation","angular limb deformity","3D-printing","patient-specific guides","computed tomography","patient-specific implants","femoral varus"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10214/26316"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Our objectives were to validate a protocol for evaluating femoral alignment in dogs with MPL using CT and use it to design and report the accuracy and repeatability of a 3D-printed DFWO guide and plate system. The angles evaluated were aLDFA including FVA, FCT, AA, IA and NAA. Repeatability for all measurements ranged from moderate (ICC = 0.65) to excellent (ICC = 0.96). Reliability ranged from good (ICC = 0.79) to excellent (ICC = 0.99). Seven femurs had varus/valgus (aLDFA) corrected to 95° and torsion (AA) corrected to 30°. The mean difference between the target and achieved was 1.29° (+/-3.58°, p = .085) for aLDFA and 3.43° (+/-5.21°, p = .012) for AA. The intraobserver ICCs for aLDFA and AA were 0.865 and 0.817, respectively. The measurement protocol was repeatable and reliable and the DFWO system provided accurate and repeatable correction of frontal plane deformities but not torsional deformities."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["Ontario Veterinary College Pet Trust"]},{"key":"dc:title","label":"Title","values":["Canine Femoral Deformities Causing Medial Patellar Luxation Characterized And Corrected Using Computed Tomography And Three-Dimensional Printing Technology"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Moens, Noel","Oblak, Michelle"],"dc:creator":["Iannitelli, Bianca"],"dc:date.accessioned":["2021-08-27T20:06:30Z"],"dc:date.available":["2021-08-27T20:06:30Z"],"dc:date.copyright":["2021-08"],"dc:date.created":["2021-06-09"],"dc:description.abstract":["Our objectives were to validate a protocol for evaluating femoral alignment in dogs with MPL using CT and use it to design and report the accuracy and repeatability of a 3D-printed DFWO guide and plate system. The angles evaluated were aLDFA including FVA, FCT, AA, IA and NAA. Repeatability for all measurements ranged from moderate (ICC = 0.65) to excellent (ICC = 0.96). Reliability ranged from good (ICC = 0.79) to excellent (ICC = 0.99). Seven femurs had varus/valgus (aLDFA) corrected to 95° and torsion (AA) corrected to 30°. The mean difference between the target and achieved was 1.29° (+/-3.58°, p = .085) for aLDFA and 3.43° (+/-5.21°, p = .012) for AA. The intraobserver ICCs for aLDFA and AA were 0.865 and 0.817, respectively. The measurement protocol was repeatable and reliable and the DFWO system provided accurate and repeatable correction of frontal plane deformities but not torsional deformities."],"dc:description.sponsorship":["Ontario Veterinary College Pet Trust"],"dc:identifier.uri":["https://hdl.handle.net/10214/26316"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["medial patellar luxation","angular limb deformity","3D-printing","patient-specific guides","computed tomography","patient-specific implants","femoral varus"],"dc:title":["Canine Femoral Deformities Causing Medial Patellar Luxation Characterized And Corrected Using Computed Tomography And Three-Dimensional Printing Technology"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["Department of Clinical Studies"],"thesis:degree_name":["Master of Science"],"thesis:degree_program":["Clinical Studies"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:23:25Z"}