{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/26679"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/26679","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"FLUTe FACT^TM Laboratory Studies on Uptake and Extraction Method Variability and Implications for Field Performance","abstract":"The FLUTE FACT^TM (FLUTe Activated Carbon Technique) is a borehole technology used for mapping contaminant distribution in the subsurface. Batch experiments were performed to determine the equilibrium partitioning behaviour of VOCs with respect to the FACT, and to assess how effectively VOC mass is desorbed from the FACT for analysis. Multiple extraction techniques were tested for effectiveness at desorbing mass from the FACT. The partitioning behaviour of the VOCs was reasonably well described by the Langmuir isotherm, with Cs max values for different VOCs ranging from 8x103 to 2x104 µmol/kg. The methanol shake flask method was the best performing extraction technique, which displayed average mass percent recovery of 96%±6%. The experiment showed that the FACT and the procedures involved in sampling the FACT display great variability in data output between replicate samples, suggesting, while still useful for delineating contaminant distribution, should not be used in a quantitative manner.","abstract_html":"The FLUTE FACT^TM (FLUTe Activated Carbon Technique) is a borehole technology used for mapping contaminant distribution in the subsurface. Batch experiments were performed to determine the equilibrium partitioning behaviour of VOCs with respect to the FACT, and to assess how effectively VOC mass is desorbed from the FACT for analysis. Multiple extraction techniques were tested for effectiveness at desorbing mass from the FACT. The partitioning behaviour of the VOCs was reasonably well described by the Langmuir isotherm, with Cs max values for different VOCs ranging from 8x103 to 2x104 µmol/kg. The methanol shake flask method was the best performing extraction technique, which displayed average mass percent recovery of 96%±6%. The experiment showed that the FACT and the procedures involved in sampling the FACT display great variability in data output between replicate samples, suggesting, while still useful for delineating contaminant distribution, should not be used in a quantitative manner.","abstract_has_math":false,"creators":["Redmond, Brent"],"institution":"University of Guelph","degree_name":"Master of Applied Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Parker, Beth"],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:24:39Z","subjects":["FLUTe FACT","FLUTe Activated Carbon Technique","borehole technology","mapping","VOC mass","contaminant distribution","subsurface"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/26679","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/26679","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F26679","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F26679","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Parker, Beth"]},{"key":"dc:creator","label":"Author","values":["Redmond, Brent"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2022-01-13T16:55:12Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2022-01-13T16:55:12Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2021-12"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2021-12-20"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["FLUTe FACT","FLUTe Activated Carbon Technique","borehole technology","mapping","VOC mass","contaminant distribution","subsurface"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10214/26679"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The FLUTE FACT^TM (FLUTe Activated Carbon Technique) is a borehole technology used for mapping contaminant distribution in the subsurface. Batch experiments were performed to determine the equilibrium partitioning behaviour of VOCs with respect to the FACT, and to assess how effectively VOC mass is desorbed from the FACT for analysis. Multiple extraction techniques were tested for effectiveness at desorbing mass from the FACT. The partitioning behaviour of the VOCs was reasonably well described by the Langmuir isotherm, with Cs max values for different VOCs ranging from 8x103 to 2x104 µmol/kg. The methanol shake flask method was the best performing extraction technique, which displayed average mass percent recovery of 96%±6%. The experiment showed that the FACT and the procedures involved in sampling the FACT display great variability in data output between replicate samples, suggesting, while still useful for delineating contaminant distribution, should not be used in a quantitative manner."]},{"key":"dc:title","label":"Title","values":["FLUTe FACT^TM Laboratory Studies on Uptake and Extraction Method Variability and Implications for Field Performance"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Parker, Beth"],"dc:creator":["Redmond, Brent"],"dc:date.accessioned":["2022-01-13T16:55:12Z"],"dc:date.available":["2022-01-13T16:55:12Z"],"dc:date.copyright":["2021-12"],"dc:date.created":["2021-12-20"],"dc:description.abstract":["The FLUTE FACT^TM (FLUTe Activated Carbon Technique) is a borehole technology used for mapping contaminant distribution in the subsurface. Batch experiments were performed to determine the equilibrium partitioning behaviour of VOCs with respect to the FACT, and to assess how effectively VOC mass is desorbed from the FACT for analysis. Multiple extraction techniques were tested for effectiveness at desorbing mass from the FACT. The partitioning behaviour of the VOCs was reasonably well described by the Langmuir isotherm, with Cs max values for different VOCs ranging from 8x103 to 2x104 µmol/kg. The methanol shake flask method was the best performing extraction technique, which displayed average mass percent recovery of 96%±6%. The experiment showed that the FACT and the procedures involved in sampling the FACT display great variability in data output between replicate samples, suggesting, while still useful for delineating contaminant distribution, should not be used in a quantitative manner."],"dc:identifier.uri":["https://hdl.handle.net/10214/26679"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["FLUTe FACT","FLUTe Activated Carbon Technique","borehole technology","mapping","VOC mass","contaminant distribution","subsurface"],"dc:title":["FLUTe FACT^TM Laboratory Studies on Uptake and Extraction Method Variability and Implications for Field Performance"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Applied Science"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:24:39Z"}