{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/26921"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/26921","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Dynamic Force Osteoarthritis Knee Brace","abstract":"Osteoarthritis affects approximately 3.9 million Canadians, and costs of total knee arthroplasties in 2010 was $4.7 million. Surgery is not feasible for all patients therefore many patients use knee braces. However, most patients stop use due to discomfort, preventing the brace from slowing the progression of OA. The design of a more comfortable knee brace that provides biomechanical advantages of current braces is necessary to improve patient compliance. Design and validation of a knee brace with two modes: dynamic, where corrective forces are only applied during stance phase, and passive mode, where forces are always applied. The brace generated an applied abduction moment 9.57Nm during static trials. Two walking trials were completed with the brace on 10 healthy participants comparing both modes. Mechanical failure occurred due to unpredicted hyperextension of the Scott Russell Mechanism. Future work should involve further dynamic analysis of the brace and improving strength in component manufacturing.","abstract_html":"Osteoarthritis affects approximately 3.9 million Canadians, and costs of total knee arthroplasties in 2010 was $4.7 million. Surgery is not feasible for all patients therefore many patients use knee braces. However, most patients stop use due to discomfort, preventing the brace from slowing the progression of OA. The design of a more comfortable knee brace that provides biomechanical advantages of current braces is necessary to improve patient compliance. Design and validation of a knee brace with two modes: dynamic, where corrective forces are only applied during stance phase, and passive mode, where forces are always applied. The brace generated an applied abduction moment 9.57Nm during static trials. Two walking trials were completed with the brace on 10 healthy participants comparing both modes. Mechanical failure occurred due to unpredicted hyperextension of the Scott Russell Mechanism. Future work should involve further dynamic analysis of the brace and improving strength in component manufacturing.","abstract_has_math":false,"creators":["Roud, Olivia"],"institution":"University of Guelph","degree_name":"Master of Applied Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Brandon, Scott","Gordon, Karen"],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:21:17Z","subjects":["osteoarthritis","knee brace","dynamic force"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/26921","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/26921","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F26921","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F26921","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Brandon, Scott","Gordon, Karen"]},{"key":"dc:creator","label":"Author","values":["Roud, Olivia"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2022-05-11T18:03:21Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2022-05-11T18:03:21Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2022-05"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2022-05-06"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["osteoarthritis","knee brace","dynamic force"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10214/26921"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Osteoarthritis affects approximately 3.9 million Canadians, and costs of total knee arthroplasties in 2010 was $4.7 million. Surgery is not feasible for all patients therefore many patients use knee braces. However, most patients stop use due to discomfort, preventing the brace from slowing the progression of OA. The design of a more comfortable knee brace that provides biomechanical advantages of current braces is necessary to improve patient compliance. Design and validation of a knee brace with two modes: dynamic, where corrective forces are only applied during stance phase, and passive mode, where forces are always applied. The brace generated an applied abduction moment 9.57Nm during static trials. Two walking trials were completed with the brace on 10 healthy participants comparing both modes. Mechanical failure occurred due to unpredicted hyperextension of the Scott Russell Mechanism. Future work should involve further dynamic analysis of the brace and improving strength in component manufacturing."]},{"key":"dc:title","label":"Title","values":["Dynamic Force Osteoarthritis Knee Brace"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Brandon, Scott","Gordon, Karen"],"dc:creator":["Roud, Olivia"],"dc:date.accessioned":["2022-05-11T18:03:21Z"],"dc:date.available":["2022-05-11T18:03:21Z"],"dc:date.copyright":["2022-05"],"dc:date.created":["2022-05-06"],"dc:description.abstract":["Osteoarthritis affects approximately 3.9 million Canadians, and costs of total knee arthroplasties in 2010 was $4.7 million. Surgery is not feasible for all patients therefore many patients use knee braces. However, most patients stop use due to discomfort, preventing the brace from slowing the progression of OA. The design of a more comfortable knee brace that provides biomechanical advantages of current braces is necessary to improve patient compliance. Design and validation of a knee brace with two modes: dynamic, where corrective forces are only applied during stance phase, and passive mode, where forces are always applied. The brace generated an applied abduction moment 9.57Nm during static trials. Two walking trials were completed with the brace on 10 healthy participants comparing both modes. Mechanical failure occurred due to unpredicted hyperextension of the Scott Russell Mechanism. Future work should involve further dynamic analysis of the brace and improving strength in component manufacturing."],"dc:identifier.uri":["https://hdl.handle.net/10214/26921"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["osteoarthritis","knee brace","dynamic force"],"dc:title":["Dynamic Force Osteoarthritis Knee Brace"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Applied Science"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:21:17Z"}