{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/27291"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/27291","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Experimental Validation of Filtered Interaction Vertex Imaging for Intra-Fraction Relative Range Verification in Heavy-Ion Therapy","abstract":"The growing societal burden of cancer necessitates improvements in the safety and efficacy of treatment. Scanned heavy-ion therapy provides precise and highly conformal radiation treatment of tumours, but it is difficult to ensure accurate dose delivery due to uncertainty surrounding ion beam range in tissue. Relative range verification via filtered interaction vertex imaging could monitor the spacing of each treatment beam endpoint, ensuring full and consistent tumour coverage. To validate this method, twelve \\(^{16}O\\) beams of differing energy irradiated a 40 mm poly-(methyl methacrylate) phantom. Secondary particles were monitored using position-sensitive silicon detectors, and used to reconstruct the depth distribution of beam-phantom nuclear reactions. Comparison of logistic fits to the distal edges of these distributions computed the range shift between two energies to sub-millimeter precision with a standard deviation of the mean of 220(10) μm, validating filtered interaction vertex imaging as a candidate for clinical high-performance range verification.","abstract_html":"The growing societal burden of cancer necessitates improvements in the safety and efficacy of treatment. Scanned heavy-ion therapy provides precise and highly conformal radiation treatment of tumours, but it is difficult to ensure accurate dose delivery due to uncertainty surrounding ion beam range in tissue. Relative range verification via filtered interaction vertex imaging could monitor the spacing of each treatment beam endpoint, ensuring full and consistent tumour coverage. To validate this method, twelve <span class=\"etd-inline-math\"><sup>16</sup>O</span> beams of differing energy irradiated a 40 mm poly-(methyl methacrylate) phantom. Secondary particles were monitored using position-sensitive silicon detectors, and used to reconstruct the depth distribution of beam-phantom nuclear reactions. Comparison of logistic fits to the distal edges of these distributions computed the range shift between two energies to sub-millimeter precision with a standard deviation of the mean of 220(10) μm, validating filtered interaction vertex imaging as a candidate for clinical high-performance range verification.","abstract_has_math":true,"creators":["Hymers, Devin"],"institution":"University of Guelph","degree_name":"Master of Science","degree_level":null,"degree_discipline":null,"degree_department":"Department of Physics","school":null,"contributors":[],"advisors":["Svensson, Carl"],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:22:35Z","subjects":["interaction vertex imaging","heavy-ion therapy","silicon detectors","range monitoring"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Hymers D, Kasanda E, Bildstein V, Easter J, Richard A, Spyrou A, Höhr C and Möcher D 2021 Intra- and inter-fraction relative range verification in heavy-ion therapy using filtered interaction vertex imaging Phys Med Biol 66 245022 https://doi.org/10.1088/1361-6560/ac3b33"],"render_values":[{"text":"Hymers D, Kasanda E, Bildstein V, Easter J, Richard A, Spyrou A, Höhr C and Möcher D 2021 Intra- and inter-fraction relative range verification in heavy-ion therapy using filtered interaction vertex imaging Phys Med Biol 66 245022 https://doi.org/10.1088/1361-6560/ac3b33","href":"https://doi.org/10.1088/1361-6560/ac3b33","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/27291","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/27291","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":"embargoed","embargo_until":"2023-01-01","access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F27291","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F27291","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Svensson, Carl"]},{"key":"dc:creator","label":"Author","values":["Hymers, Devin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2022-10-18T16:55:27Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2022-10"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2022-10-14"]},{"key":"dc:date.embargo","label":"Dc Date Embargo","values":["2023-01-01"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Department of Physics"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["interaction vertex imaging","heavy-ion therapy","silicon detectors","range monitoring"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Hymers D, Kasanda E, Bildstein V, Easter J, Richard A, Spyrou A, Höhr C and Möcher D 2021 Intra- and inter-fraction relative range verification in heavy-ion therapy using filtered interaction vertex imaging Phys Med Biol 66 245022 https://doi.org/10.1088/1361-6560/ac3b33"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10214/27291"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The growing societal burden of cancer necessitates improvements in the safety and efficacy of treatment. Scanned heavy-ion therapy provides precise and highly conformal radiation treatment of tumours, but it is difficult to ensure accurate dose delivery due to uncertainty surrounding ion beam range in tissue. Relative range verification via filtered interaction vertex imaging could monitor the spacing of each treatment beam endpoint, ensuring full and consistent tumour coverage. To validate this method, twelve \\(^{16}O\\) beams of differing energy irradiated a 40 mm poly-(methyl methacrylate) phantom. Secondary particles were monitored using position-sensitive silicon detectors, and used to reconstruct the depth distribution of beam-phantom nuclear reactions. Comparison of logistic fits to the distal edges of these distributions computed the range shift between two energies to sub-millimeter precision with a standard deviation of the mean of 220(10) μm, validating filtered interaction vertex imaging as a candidate for clinical high-performance range verification."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["Canadian Institutes of Health Research","Natural Sciences and Engineering Research Council of Canada","Social Sciences and Humanities Research Council of Canada","Ontario Graduate Scholarship","Shared Hierarchical Academic Research Computing Network","Compute Canada","National Science Foundation"]},{"key":"dc:title","label":"Title","values":["Experimental Validation of Filtered Interaction Vertex Imaging for Intra-Fraction Relative Range Verification in Heavy-Ion Therapy"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Svensson, Carl"],"dc:creator":["Hymers, Devin"],"dc:date.accessioned":["2022-10-18T16:55:27Z"],"dc:date.copyright":["2022-10"],"dc:date.created":["2022-10-14"],"dc:date.embargo":["2023-01-01"],"dc:description.abstract":["The growing societal burden of cancer necessitates improvements in the safety and efficacy of treatment. Scanned heavy-ion therapy provides precise and highly conformal radiation treatment of tumours, but it is difficult to ensure accurate dose delivery due to uncertainty surrounding ion beam range in tissue. Relative range verification via filtered interaction vertex imaging could monitor the spacing of each treatment beam endpoint, ensuring full and consistent tumour coverage. To validate this method, twelve \\(^{16}O\\) beams of differing energy irradiated a 40 mm poly-(methyl methacrylate) phantom. Secondary particles were monitored using position-sensitive silicon detectors, and used to reconstruct the depth distribution of beam-phantom nuclear reactions. Comparison of logistic fits to the distal edges of these distributions computed the range shift between two energies to sub-millimeter precision with a standard deviation of the mean of 220(10) μm, validating filtered interaction vertex imaging as a candidate for clinical high-performance range verification."],"dc:description.sponsorship":["Canadian Institutes of Health Research","Natural Sciences and Engineering Research Council of Canada","Social Sciences and Humanities Research Council of Canada","Ontario Graduate Scholarship","Shared Hierarchical Academic Research Computing Network","Compute Canada","National Science Foundation"],"dc:identifier.citation":["Hymers D, Kasanda E, Bildstein V, Easter J, Richard A, Spyrou A, Höhr C and Möcher D 2021 Intra- and inter-fraction relative range verification in heavy-ion therapy using filtered interaction vertex imaging Phys Med Biol 66 245022 https://doi.org/10.1088/1361-6560/ac3b33"],"dc:identifier.uri":["https://hdl.handle.net/10214/27291"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["interaction vertex imaging","heavy-ion therapy","silicon detectors","range monitoring"],"dc:title":["Experimental Validation of Filtered Interaction Vertex Imaging for Intra-Fraction Relative Range Verification in Heavy-Ion Therapy"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["Department of Physics"],"thesis:degree_name":["Master of Science"],"thesis:degree_program":["Physics"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:22:35Z"}