{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/27334"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/27334","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Climate Zone-Based Energy Retrofits in Canada For Current and Future Climate Change Scenarios","abstract":"The research objective was to investigate mitigation measures for reduction of energy use, emissions, and costs, for a residential house in current and future climates in Vancouver and Toronto, representing climate zones 4 and 5, respectively. The mitigation strategies investigated were: increasing vegetation, increasing thermal resistance, decreasing infiltration/exfiltration, adding a cool roof, and adding photovoltaic panels. Energy consumption simulations were conducted using the Vertical City Weather Generator (VCWG) software. Future climate data was obtained form CanRCM4 files under Representative Concentration Pathway (RCP) 4.5 and 8.5 [W m^{-2}] . The largest cost and CO_2e savings in Vancouver and Toronto came from the reduction in infiltration/exfiltration. The economic analysis showed that cost savings for mitigation efforts are dependent on individual costs in each city. Electricity prices in Vancouver were cheap, which made the use of PV systems too expensive. However, in Toronto the high price of electricity made PV systems cost effective.","abstract_html":"The research objective was to investigate mitigation measures for reduction of energy use, emissions, and costs, for a residential house in current and future climates in Vancouver and Toronto, representing climate zones 4 and 5, respectively. The mitigation strategies investigated were: increasing vegetation, increasing thermal resistance, decreasing infiltration/exfiltration, adding a cool roof, and adding photovoltaic panels. Energy consumption simulations were conducted using the Vertical City Weather Generator (VCWG) software. Future climate data was obtained form CanRCM4 files under Representative Concentration Pathway (RCP) 4.5 and 8.5 [W m^{-2}] . The largest cost and CO_2e savings in Vancouver and Toronto came from the reduction in infiltration/exfiltration. The economic analysis showed that cost savings for mitigation efforts are dependent on individual costs in each city. Electricity prices in Vancouver were cheap, which made the use of PV systems too expensive. However, in Toronto the high price of electricity made PV systems cost effective.","abstract_has_math":false,"creators":["McLeod, Rachel M."],"institution":"University of Guelph","degree_name":"Master of Applied Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Aliabadi, Amir A."],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:22:27Z","subjects":["representative concentration pathways","carbon emissions","building retrofits","building energy economic analysis","building energy reduction"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/27334","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/27334","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F27334","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F27334","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Aliabadi, Amir A."]},{"key":"dc:creator","label":"Author","values":["McLeod, Rachel M."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2022-12-20T17:45:52Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2022-12-20T17:45:52Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2022-12"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2022-12-06"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["representative concentration pathways","carbon emissions","building retrofits","building energy economic analysis","building energy reduction"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10214/27334"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The research objective was to investigate mitigation measures for reduction of energy use, emissions, and costs, for a residential house in current and future climates in Vancouver and Toronto, representing climate zones 4 and 5, respectively. The mitigation strategies investigated were: increasing vegetation, increasing thermal resistance, decreasing infiltration/exfiltration, adding a cool roof, and adding photovoltaic panels. Energy consumption simulations were conducted using the Vertical City Weather Generator (VCWG) software. Future climate data was obtained form CanRCM4 files under Representative Concentration Pathway (RCP) 4.5 and 8.5 [W m^{-2}] . The largest cost and CO_2e savings in Vancouver and Toronto came from the reduction in infiltration/exfiltration. The economic analysis showed that cost savings for mitigation efforts are dependent on individual costs in each city. Electricity prices in Vancouver were cheap, which made the use of PV systems too expensive. However, in Toronto the high price of electricity made PV systems cost effective."]},{"key":"dc:title","label":"Title","values":["Climate Zone-Based Energy Retrofits in Canada For Current and Future Climate Change Scenarios"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Aliabadi, Amir A."],"dc:creator":["McLeod, Rachel M."],"dc:date.accessioned":["2022-12-20T17:45:52Z"],"dc:date.available":["2022-12-20T17:45:52Z"],"dc:date.copyright":["2022-12"],"dc:date.created":["2022-12-06"],"dc:description.abstract":["The research objective was to investigate mitigation measures for reduction of energy use, emissions, and costs, for a residential house in current and future climates in Vancouver and Toronto, representing climate zones 4 and 5, respectively. The mitigation strategies investigated were: increasing vegetation, increasing thermal resistance, decreasing infiltration/exfiltration, adding a cool roof, and adding photovoltaic panels. Energy consumption simulations were conducted using the Vertical City Weather Generator (VCWG) software. Future climate data was obtained form CanRCM4 files under Representative Concentration Pathway (RCP) 4.5 and 8.5 [W m^{-2}] . The largest cost and CO_2e savings in Vancouver and Toronto came from the reduction in infiltration/exfiltration. The economic analysis showed that cost savings for mitigation efforts are dependent on individual costs in each city. Electricity prices in Vancouver were cheap, which made the use of PV systems too expensive. However, in Toronto the high price of electricity made PV systems cost effective."],"dc:identifier.uri":["https://hdl.handle.net/10214/27334"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["representative concentration pathways","carbon emissions","building retrofits","building energy economic analysis","building energy reduction"],"dc:title":["Climate Zone-Based Energy Retrofits in Canada For Current and Future Climate Change Scenarios"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Applied Science"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:22:27Z"}