{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/27394"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/27394","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Topics in PIXE Analysis","abstract":"Proton induced x-ray emission spectroscopy (PIXE) sees widespread use in a variety of materials analysis applications. With the goal of improving the accuracy of PIXE results several projects are undertaken. In this work changes to beam visualization and beam-size calibration are described. An examination of various theoretical cross-section databases is performed, showing that extending the currently used ECPSSR theory through united-atom and intra-shell corrections is unlikely to offer an improvement to PIXE results. It is also shown that the diminishing energy of protons in thick samples is unlikely to be the cause of aberrant results previously seen for certain elements. A detailed examination of pure-element thick and thin samples suggests that cross-section databases for studied elements agree with experimental results. Finally, data from Ito et. al. and Kavcic et. al. are used to successfully improve the shape of the K-$\\beta$ x-ray line of iron, resulting in a more accurate fit.","abstract_html":"Proton induced x-ray emission spectroscopy (PIXE) sees widespread use in a variety of materials analysis applications. With the goal of improving the accuracy of PIXE results several projects are undertaken. In this work changes to beam visualization and beam-size calibration are described. An examination of various theoretical cross-section databases is performed, showing that extending the currently used ECPSSR theory through united-atom and intra-shell corrections is unlikely to offer an improvement to PIXE results. It is also shown that the diminishing energy of protons in thick samples is unlikely to be the cause of aberrant results previously seen for certain elements. A detailed examination of pure-element thick and thin samples suggests that cross-section databases for studied elements agree with experimental results. Finally, data from Ito et. al. and Kavcic et. al. are used to successfully improve the shape of the K-<span class=\"etd-inline-math\">&beta;</span> x-ray line of iron, resulting in a more accurate fit.","abstract_has_math":true,"creators":["Martin, Peter"],"institution":"University of Guelph","degree_name":"Master of Science","degree_level":null,"degree_discipline":null,"degree_department":"Department of Physics","school":null,"contributors":[],"advisors":["Campbell, John L. (Iain)","O'Meara, Joanne"],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:27:45Z","subjects":["ECPSSR","thick sample analysis","thin sample analysis","united atom correction","intra shell correction","PIXE","proton beam","spectroscopy","k-Beta transition lines"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/27394","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/27394","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F27394","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F27394","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Campbell, John L. (Iain)","O'Meara, Joanne"]},{"key":"dc:creator","label":"Author","values":["Martin, Peter"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2023-01-09T19:04:49Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2023-01-09T19:04:49Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2023-01-09"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2022-09-28"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Department of Physics"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["ECPSSR","thick sample analysis","thin sample analysis","united atom correction","intra shell correction","PIXE","proton beam","spectroscopy","k-Beta transition lines"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10214/27394"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Proton induced x-ray emission spectroscopy (PIXE) sees widespread use in a variety of materials analysis applications. With the goal of improving the accuracy of PIXE results several projects are undertaken. In this work changes to beam visualization and beam-size calibration are described. An examination of various theoretical cross-section databases is performed, showing that extending the currently used ECPSSR theory through united-atom and intra-shell corrections is unlikely to offer an improvement to PIXE results. It is also shown that the diminishing energy of protons in thick samples is unlikely to be the cause of aberrant results previously seen for certain elements. A detailed examination of pure-element thick and thin samples suggests that cross-section databases for studied elements agree with experimental results. Finally, data from Ito et. al. and Kavcic et. al. are used to successfully improve the shape of the K-$\\beta$ x-ray line of iron, resulting in a more accurate fit."]},{"key":"dc:title","label":"Title","values":["Topics in PIXE Analysis"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Campbell, John L. (Iain)","O'Meara, Joanne"],"dc:creator":["Martin, Peter"],"dc:date.accessioned":["2023-01-09T19:04:49Z"],"dc:date.available":["2023-01-09T19:04:49Z"],"dc:date.copyright":["2023-01-09"],"dc:date.created":["2022-09-28"],"dc:description.abstract":["Proton induced x-ray emission spectroscopy (PIXE) sees widespread use in a variety of materials analysis applications. With the goal of improving the accuracy of PIXE results several projects are undertaken. In this work changes to beam visualization and beam-size calibration are described. An examination of various theoretical cross-section databases is performed, showing that extending the currently used ECPSSR theory through united-atom and intra-shell corrections is unlikely to offer an improvement to PIXE results. It is also shown that the diminishing energy of protons in thick samples is unlikely to be the cause of aberrant results previously seen for certain elements. A detailed examination of pure-element thick and thin samples suggests that cross-section databases for studied elements agree with experimental results. Finally, data from Ito et. al. and Kavcic et. al. are used to successfully improve the shape of the K-$\\beta$ x-ray line of iron, resulting in a more accurate fit."],"dc:identifier.uri":["https://hdl.handle.net/10214/27394"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["ECPSSR","thick sample analysis","thin sample analysis","united atom correction","intra shell correction","PIXE","proton beam","spectroscopy","k-Beta transition lines"],"dc:title":["Topics in PIXE Analysis"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["Department of Physics"],"thesis:degree_name":["Master of Science"],"thesis:degree_program":["Physics"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:27:45Z"}