{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/27446"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/27446","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"The potential risk of firefighting water additives used during forest fires used to aquatic and terrestrial organisms","abstract":"Firefighting water additives improve extinguishing efficiency in both urban and rural settings. The rate and size of forest fires has increased due to anthropogenic factors, making the use of the most efficient fighting tactics extremely relevant. There exists little ecotoxicological data available for many of the products in current use. The aim of this study is to assess the toxicity of firefighting additives currently used in Canada to a variety of aquatic and terrestrial species. Additionally, a deterministic risk assessment was conducted for both aquatic and terrestrial species based off environmentally relevant rates of application. Several of the firefighting water additives tested were found to pose risks to a variety of the species tested, whereas some products appeared to be relatively safe under the worse-case hypothetical scenarios.","abstract_html":"Firefighting water additives improve extinguishing efficiency in both urban and rural settings. The rate and size of forest fires has increased due to anthropogenic factors, making the use of the most efficient fighting tactics extremely relevant. There exists little ecotoxicological data available for many of the products in current use. The aim of this study is to assess the toxicity of firefighting additives currently used in Canada to a variety of aquatic and terrestrial species. Additionally, a deterministic risk assessment was conducted for both aquatic and terrestrial species based off environmentally relevant rates of application. Several of the firefighting water additives tested were found to pose risks to a variety of the species tested, whereas some products appeared to be relatively safe under the worse-case hypothetical scenarios.","abstract_has_math":false,"creators":["Anderson, Jenna"],"institution":"University of Guelph","degree_name":"Master of Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Environmental Sciences","school":null,"contributors":[],"advisors":["Prosser, Ryan"],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:27:45Z","subjects":["firefighting chemcials","firefighting water additives","soil organisms","retardants","fluorine-free foams","risk assessment","terrestrial toxicity","aquatic toxicity"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Anderson, J., Prosser, R.S. 2023. Potential Risk to Aquatic Biota from Aerial Application of Firefighting Water Additives. Environmental Pollution. 316(1) https://doi.org/10.1016/j.envpol.2022.120651."],"render_values":[{"text":"Anderson, J., Prosser, R.S. 2023. Potential Risk to Aquatic Biota from Aerial Application of Firefighting Water Additives. Environmental Pollution. 316(1) https://doi.org/10.1016/j.envpol.2022.120651.","href":"https://doi.org/10.1016/j.envpol.2022.120651.","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/27446","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/27446","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F27446","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F27446","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Prosser, Ryan"]},{"key":"dc:creator","label":"Author","values":["Anderson, Jenna"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2023-01-13T19:24:54Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2023-01-13T19:24:54Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2023-01"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2022-12-19"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Environmental Sciences"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Environmental Sciences"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["firefighting chemcials","firefighting water additives","soil organisms","retardants","fluorine-free foams","risk assessment","terrestrial toxicity","aquatic toxicity"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Anderson, J., Prosser, R.S. 2023. Potential Risk to Aquatic Biota from Aerial Application of Firefighting Water Additives. Environmental Pollution. 316(1) https://doi.org/10.1016/j.envpol.2022.120651."]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10214/27446"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Firefighting water additives improve extinguishing efficiency in both urban and rural settings. The rate and size of forest fires has increased due to anthropogenic factors, making the use of the most efficient fighting tactics extremely relevant. There exists little ecotoxicological data available for many of the products in current use. The aim of this study is to assess the toxicity of firefighting additives currently used in Canada to a variety of aquatic and terrestrial species. Additionally, a deterministic risk assessment was conducted for both aquatic and terrestrial species based off environmentally relevant rates of application. Several of the firefighting water additives tested were found to pose risks to a variety of the species tested, whereas some products appeared to be relatively safe under the worse-case hypothetical scenarios."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["Mitacs","Fire Rein"]},{"key":"dc:title","label":"Title","values":["The potential risk of firefighting water additives used during forest fires used to aquatic and terrestrial organisms"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Prosser, Ryan"],"dc:creator":["Anderson, Jenna"],"dc:date.accessioned":["2023-01-13T19:24:54Z"],"dc:date.available":["2023-01-13T19:24:54Z"],"dc:date.copyright":["2023-01"],"dc:date.created":["2022-12-19"],"dc:description.abstract":["Firefighting water additives improve extinguishing efficiency in both urban and rural settings. The rate and size of forest fires has increased due to anthropogenic factors, making the use of the most efficient fighting tactics extremely relevant. There exists little ecotoxicological data available for many of the products in current use. The aim of this study is to assess the toxicity of firefighting additives currently used in Canada to a variety of aquatic and terrestrial species. Additionally, a deterministic risk assessment was conducted for both aquatic and terrestrial species based off environmentally relevant rates of application. Several of the firefighting water additives tested were found to pose risks to a variety of the species tested, whereas some products appeared to be relatively safe under the worse-case hypothetical scenarios."],"dc:description.sponsorship":["Mitacs","Fire Rein"],"dc:identifier.citation":["Anderson, J., Prosser, R.S. 2023. Potential Risk to Aquatic Biota from Aerial Application of Firefighting Water Additives. Environmental Pollution. 316(1) https://doi.org/10.1016/j.envpol.2022.120651."],"dc:identifier.uri":["https://hdl.handle.net/10214/27446"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["firefighting chemcials","firefighting water additives","soil organisms","retardants","fluorine-free foams","risk assessment","terrestrial toxicity","aquatic toxicity"],"dc:title":["The potential risk of firefighting water additives used during forest fires used to aquatic and terrestrial organisms"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Environmental Sciences"],"thesis:degree_name":["Master of Science"],"thesis:degree_program":["Environmental Sciences"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:27:45Z"}