{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/27567"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/27567","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Investigating the Transient Performance of Drain Water Heat Recovery Systems: A Comparative Study of Conventional and Novel Devices from Thermal and Economical Perspectives","abstract":"A drain water heat recovery (DWHR) device is a heat exchanger that recovers heat from warm grey water in buildings. This thesis examines the transient performance of DWHR devices through experimental and analytical investigations. Thermal performance analyses were conducted, and two transient mathematical models were developed. The first model predicts overall system transient performance based on the DWHR device's operating conditions, while the second model focuses on the DWHR device itself as a counter-flow heat exchanger, taking into account the thermal inertia of the solid material, and hot and cold fluids. A novel DWHR device was designed, manufactured, and tested identical to a conventional device. The novel device exhibited lower thermal resistances compared to the conventional one, leading to improved thermal performance. The experimental data validate both mathematical models. The models and experimental results reveal that a substantial reduction in actual effectiveness occurs during short and frequent hot water usage.","abstract_html":"A drain water heat recovery (DWHR) device is a heat exchanger that recovers heat from warm grey water in buildings. This thesis examines the transient performance of DWHR devices through experimental and analytical investigations. Thermal performance analyses were conducted, and two transient mathematical models were developed. The first model predicts overall system transient performance based on the DWHR device&#x27;s operating conditions, while the second model focuses on the DWHR device itself as a counter-flow heat exchanger, taking into account the thermal inertia of the solid material, and hot and cold fluids. A novel DWHR device was designed, manufactured, and tested identical to a conventional device. The novel device exhibited lower thermal resistances compared to the conventional one, leading to improved thermal performance. The experimental data validate both mathematical models. The models and experimental results reveal that a substantial reduction in actual effectiveness occurs during short and frequent hot water usage.","abstract_has_math":false,"creators":["Ovadia, Ezra"],"institution":"University of Guelph","degree_name":"Master of Applied Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Elsharqawy, Mostafa"],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:25:07Z","subjects":["transient analysis","drain water heat recovery","greywater","heat exchanger","experimental"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/27567","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/27567","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":"embargoed","embargo_until":"2024-05-04","access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F27567","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F27567","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Elsharqawy, Mostafa"]},{"key":"dc:creator","label":"Author","values":["Ovadia, Ezra"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2023-05-12T16:00:01Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2023-05"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2023-05-04"]},{"key":"dc:date.embargo","label":"Dc Date Embargo","values":["2024-05-04"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["transient analysis","drain water heat recovery","greywater","heat exchanger","experimental"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10214/27567"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A drain water heat recovery (DWHR) device is a heat exchanger that recovers heat from warm grey water in buildings. This thesis examines the transient performance of DWHR devices through experimental and analytical investigations. Thermal performance analyses were conducted, and two transient mathematical models were developed. The first model predicts overall system transient performance based on the DWHR device's operating conditions, while the second model focuses on the DWHR device itself as a counter-flow heat exchanger, taking into account the thermal inertia of the solid material, and hot and cold fluids. A novel DWHR device was designed, manufactured, and tested identical to a conventional device. The novel device exhibited lower thermal resistances compared to the conventional one, leading to improved thermal performance. The experimental data validate both mathematical models. The models and experimental results reveal that a substantial reduction in actual effectiveness occurs during short and frequent hot water usage."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["Natural Sciences and Engineering Research Council of Canada"]},{"key":"dc:title","label":"Title","values":["Investigating the Transient Performance of Drain Water Heat Recovery Systems: A Comparative Study of Conventional and Novel Devices from Thermal and Economical Perspectives"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Elsharqawy, Mostafa"],"dc:creator":["Ovadia, Ezra"],"dc:date.accessioned":["2023-05-12T16:00:01Z"],"dc:date.copyright":["2023-05"],"dc:date.created":["2023-05-04"],"dc:date.embargo":["2024-05-04"],"dc:description.abstract":["A drain water heat recovery (DWHR) device is a heat exchanger that recovers heat from warm grey water in buildings. This thesis examines the transient performance of DWHR devices through experimental and analytical investigations. Thermal performance analyses were conducted, and two transient mathematical models were developed. The first model predicts overall system transient performance based on the DWHR device's operating conditions, while the second model focuses on the DWHR device itself as a counter-flow heat exchanger, taking into account the thermal inertia of the solid material, and hot and cold fluids. A novel DWHR device was designed, manufactured, and tested identical to a conventional device. The novel device exhibited lower thermal resistances compared to the conventional one, leading to improved thermal performance. The experimental data validate both mathematical models. The models and experimental results reveal that a substantial reduction in actual effectiveness occurs during short and frequent hot water usage."],"dc:description.sponsorship":["Natural Sciences and Engineering Research Council of Canada"],"dc:identifier.uri":["https://hdl.handle.net/10214/27567"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights.license":["All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated."],"dc:subject":["transient analysis","drain water heat recovery","greywater","heat exchanger","experimental"],"dc:title":["Investigating the Transient Performance of Drain Water Heat Recovery Systems: A Comparative Study of Conventional and Novel Devices from Thermal and Economical Perspectives"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Applied Science"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:25:07Z"}