{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/27682"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/27682","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Minimally Invasive Laparoscopic Liver Biopsy and Near-Infrared Fluorescence Cholangiography in the Diagnosis and Imaging of Canine Liver Disease","abstract":"Minimally invasive hepatobiliary diagnostic instruments and imaging were investigated in two separate studies. In the first study, comparison between paired laparoscopic liver biopsy (LLB) samples using 3 and 5 mm cup biopsy forceps (CBF) was performed in 10 dogs with hepatobiliary disease. Samples were compared for portal triad and lobule counts, collection artifacts, copper quantification, bacterial culture results as well as agreement of histopathologic diagnosis. All dogs successfully underwent liver biopsy using both CBF which resulted in minimal hemorrhage. An average of 12.13 (CL: 9.41-14.84) and 17.84 (CL: 15.12-20.55) portal triads were obtained using the 3 mm and the 5 mm CBF, respectively (P = 0.0003). Portal triad count was ≥11 in 73.33% of the 3 mm and 93.33% of the 5 mm samples. Histopathologic diagnosis agreement was measured using Gwets AC1 coefficient and shown to be excellent (0.814) (P < 0.0001). Although the 3 mm CBF provides smaller samples and portal triad count, these are adequate for histopathologic interpretation, copper quantification and bacterial culture which makes it suitable for LLB in small dogs. In the second study, the optimal dose and timing of administration of indocyanine green (ICG) for near-infrared fluorescence (NIRF) cholangiography in dogs was investigated. Eight healthy beagle dogs were randomized to receive 2 of 4 intravenous ICG dose (low (L): 0.05 mg/kg or high (H): 0.25 mg/kg IV)/time (0 and 3h prior to NIRF imaging) combinations. Dogs were instrumented for laparoscopy and NIRF images were collected every 10 minutes for 120 minutes. Fluorescence intensity measurements were performed to calculate target (cystic duct)-to-background (liver) ratios for all timepoints and compared. Cholangiography using ICG was safe and successful in all dogs. Contrast ratios above 2 were maintained from 180-300 minutes for L3 and H3 but were overall highest in the L3 group where the cystic duct was nearly four times as bright as the liver (3.98 at 280 minutes). The 0.05 mg/kg ICG dose provided the best contrast ratios from 3-5 h following injection and should be investigated in dogs with biliary disease requiring laparoscopic cholecystectomy.","abstract_html":"Minimally invasive hepatobiliary diagnostic instruments and imaging were investigated in two separate studies. In the first study, comparison between paired laparoscopic liver biopsy (LLB) samples using 3 and 5 mm cup biopsy forceps (CBF) was performed in 10 dogs with hepatobiliary disease. Samples were compared for portal triad and lobule counts, collection artifacts, copper quantification, bacterial culture results as well as agreement of histopathologic diagnosis. All dogs successfully underwent liver biopsy using both CBF which resulted in minimal hemorrhage. An average of 12.13 (CL: 9.41-14.84) and 17.84 (CL: 15.12-20.55) portal triads were obtained using the 3 mm and the 5 mm CBF, respectively (P = 0.0003). Portal triad count was ≥11 in 73.33% of the 3 mm and 93.33% of the 5 mm samples. Histopathologic diagnosis agreement was measured using Gwets AC1 coefficient and shown to be excellent (0.814) (P &lt; 0.0001). Although the 3 mm CBF provides smaller samples and portal triad count, these are adequate for histopathologic interpretation, copper quantification and bacterial culture which makes it suitable for LLB in small dogs. In the second study, the optimal dose and timing of administration of indocyanine green (ICG) for near-infrared fluorescence (NIRF) cholangiography in dogs was investigated. Eight healthy beagle dogs were randomized to receive 2 of 4 intravenous ICG dose (low (L): 0.05 mg/kg or high (H): 0.25 mg/kg IV)/time (0 and 3h prior to NIRF imaging) combinations. Dogs were instrumented for laparoscopy and NIRF images were collected every 10 minutes for 120 minutes. Fluorescence intensity measurements were performed to calculate target (cystic duct)-to-background (liver) ratios for all timepoints and compared. Cholangiography using ICG was safe and successful in all dogs. Contrast ratios above 2 were maintained from 180-300 minutes for L3 and H3 but were overall highest in the L3 group where the cystic duct was nearly four times as bright as the liver (3.98 at 280 minutes). The 0.05 mg/kg ICG dose provided the best contrast ratios from 3-5 h following injection and should be investigated in dogs with biliary disease requiring laparoscopic cholecystectomy.","abstract_has_math":false,"creators":["Chagnon Larose, Philippe"],"institution":"University of Guelph","degree_name":"Doctor of Veterinary Science","degree_level":null,"degree_discipline":null,"degree_department":"Department of Clinical Studies","school":null,"contributors":[],"advisors":["Brisson, Brigitte"],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:25:48Z","subjects":["cholangiography","near-infrared fluorescence imaging","near-infrared fluorescence cholangiography","canine","dog","laparoscopic cholecystectomy","indocyanine green","ICG","laparoscopy","liver biopsy","laparoscopic liver biopsy","dogs","cup biopsy forceps","copper"],"languages":["en"],"rights":["Attribution-NonCommercial-NoDerivatives 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/27682","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/27682","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F27682","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F27682","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Brisson, Brigitte"]},{"key":"dc:creator","label":"Author","values":["Chagnon Larose, Philippe"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2023-07-12T15:43:52Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2023-07-12T15:43:52Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2023-06"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2023-06-19"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Department of Clinical Studies"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Veterinary Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Clinical Studies"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["cholangiography","near-infrared fluorescence imaging","near-infrared fluorescence cholangiography","canine","dog","laparoscopic cholecystectomy","indocyanine green","ICG","laparoscopy","liver biopsy","laparoscopic liver biopsy","dogs","cup biopsy forceps","copper"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution-NonCommercial-NoDerivatives 4.0 International"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://creativecommons.org/licenses/by-nc-nd/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10214/27682"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Minimally invasive hepatobiliary diagnostic instruments and imaging were investigated in two separate studies. In the first study, comparison between paired laparoscopic liver biopsy (LLB) samples using 3 and 5 mm cup biopsy forceps (CBF) was performed in 10 dogs with hepatobiliary disease. Samples were compared for portal triad and lobule counts, collection artifacts, copper quantification, bacterial culture results as well as agreement of histopathologic diagnosis. All dogs successfully underwent liver biopsy using both CBF which resulted in minimal hemorrhage. An average of 12.13 (CL: 9.41-14.84) and 17.84 (CL: 15.12-20.55) portal triads were obtained using the 3 mm and the 5 mm CBF, respectively (P = 0.0003). Portal triad count was ≥11 in 73.33% of the 3 mm and 93.33% of the 5 mm samples. Histopathologic diagnosis agreement was measured using Gwets AC1 coefficient and shown to be excellent (0.814) (P < 0.0001). Although the 3 mm CBF provides smaller samples and portal triad count, these are adequate for histopathologic interpretation, copper quantification and bacterial culture which makes it suitable for LLB in small dogs. In the second study, the optimal dose and timing of administration of indocyanine green (ICG) for near-infrared fluorescence (NIRF) cholangiography in dogs was investigated. Eight healthy beagle dogs were randomized to receive 2 of 4 intravenous ICG dose (low (L): 0.05 mg/kg or high (H): 0.25 mg/kg IV)/time (0 and 3h prior to NIRF imaging) combinations. Dogs were instrumented for laparoscopy and NIRF images were collected every 10 minutes for 120 minutes. Fluorescence intensity measurements were performed to calculate target (cystic duct)-to-background (liver) ratios for all timepoints and compared. Cholangiography using ICG was safe and successful in all dogs. Contrast ratios above 2 were maintained from 180-300 minutes for L3 and H3 but were overall highest in the L3 group where the cystic duct was nearly four times as bright as the liver (3.98 at 280 minutes). The 0.05 mg/kg ICG dose provided the best contrast ratios from 3-5 h following injection and should be investigated in dogs with biliary disease requiring laparoscopic cholecystectomy."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["American College of Veterinary Surgeons Foundation","Ontario Veterinary College Pet Trust"]},{"key":"dc:title","label":"Title","values":["Minimally Invasive Laparoscopic Liver Biopsy and Near-Infrared Fluorescence Cholangiography in the Diagnosis and Imaging of Canine Liver Disease"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Brisson, Brigitte"],"dc:creator":["Chagnon Larose, Philippe"],"dc:date.accessioned":["2023-07-12T15:43:52Z"],"dc:date.available":["2023-07-12T15:43:52Z"],"dc:date.copyright":["2023-06"],"dc:date.created":["2023-06-19"],"dc:description.abstract":["Minimally invasive hepatobiliary diagnostic instruments and imaging were investigated in two separate studies. In the first study, comparison between paired laparoscopic liver biopsy (LLB) samples using 3 and 5 mm cup biopsy forceps (CBF) was performed in 10 dogs with hepatobiliary disease. Samples were compared for portal triad and lobule counts, collection artifacts, copper quantification, bacterial culture results as well as agreement of histopathologic diagnosis. All dogs successfully underwent liver biopsy using both CBF which resulted in minimal hemorrhage. An average of 12.13 (CL: 9.41-14.84) and 17.84 (CL: 15.12-20.55) portal triads were obtained using the 3 mm and the 5 mm CBF, respectively (P = 0.0003). Portal triad count was ≥11 in 73.33% of the 3 mm and 93.33% of the 5 mm samples. Histopathologic diagnosis agreement was measured using Gwets AC1 coefficient and shown to be excellent (0.814) (P < 0.0001). Although the 3 mm CBF provides smaller samples and portal triad count, these are adequate for histopathologic interpretation, copper quantification and bacterial culture which makes it suitable for LLB in small dogs. In the second study, the optimal dose and timing of administration of indocyanine green (ICG) for near-infrared fluorescence (NIRF) cholangiography in dogs was investigated. Eight healthy beagle dogs were randomized to receive 2 of 4 intravenous ICG dose (low (L): 0.05 mg/kg or high (H): 0.25 mg/kg IV)/time (0 and 3h prior to NIRF imaging) combinations. Dogs were instrumented for laparoscopy and NIRF images were collected every 10 minutes for 120 minutes. Fluorescence intensity measurements were performed to calculate target (cystic duct)-to-background (liver) ratios for all timepoints and compared. Cholangiography using ICG was safe and successful in all dogs. Contrast ratios above 2 were maintained from 180-300 minutes for L3 and H3 but were overall highest in the L3 group where the cystic duct was nearly four times as bright as the liver (3.98 at 280 minutes). The 0.05 mg/kg ICG dose provided the best contrast ratios from 3-5 h following injection and should be investigated in dogs with biliary disease requiring laparoscopic cholecystectomy."],"dc:description.sponsorship":["American College of Veterinary Surgeons Foundation","Ontario Veterinary College Pet Trust"],"dc:identifier.uri":["https://hdl.handle.net/10214/27682"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights":["Attribution-NonCommercial-NoDerivatives 4.0 International"],"dc:rights.uri":["http://creativecommons.org/licenses/by-nc-nd/4.0/"],"dc:subject":["cholangiography","near-infrared fluorescence imaging","near-infrared fluorescence cholangiography","canine","dog","laparoscopic cholecystectomy","indocyanine green","ICG","laparoscopy","liver biopsy","laparoscopic liver biopsy","dogs","cup biopsy forceps","copper"],"dc:title":["Minimally Invasive Laparoscopic Liver Biopsy and Near-Infrared Fluorescence Cholangiography in the Diagnosis and Imaging of Canine Liver Disease"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["Department of Clinical Studies"],"thesis:degree_name":["Doctor of Veterinary Science"],"thesis:degree_program":["Clinical Studies"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:25:48Z"}