{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/27780"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/27780","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"A Novel Knee Brace Perturbation Device Tested on Healthy Control Subjects: Quantifying Perturbation Responses During Gait","abstract":"Knee instability has been extensively studied over the last decade as it limits mobility, increases the risk of falls, and leads to longer rehabilitation periods. To better understand the impact of knee instability on knee joint function, innovative research that challenges knee stability, beyond walking surface translations, is needed. This study aimed to validate a novel knee brace perturbation device that directly challenges the knee during gait. Eighteen healthy participants completed one walking trial as the brace delivered six single-perturbations in random order: three during double-limb support (DS), and three during single-limb support (SS). In the step during and the step after the perturbation, elevated neuromuscular responses were observed irrespective of the perturbation timing (DS versus SS). These results suggest that the knee is equally destabilized following a direct perturbation during DS and SS. Future work should extend this novel direct knee perturbation paradigm to participants with unstable knees.","abstract_html":"Knee instability has been extensively studied over the last decade as it limits mobility, increases the risk of falls, and leads to longer rehabilitation periods. To better understand the impact of knee instability on knee joint function, innovative research that challenges knee stability, beyond walking surface translations, is needed. This study aimed to validate a novel knee brace perturbation device that directly challenges the knee during gait. Eighteen healthy participants completed one walking trial as the brace delivered six single-perturbations in random order: three during double-limb support (DS), and three during single-limb support (SS). In the step during and the step after the perturbation, elevated neuromuscular responses were observed irrespective of the perturbation timing (DS versus SS). These results suggest that the knee is equally destabilized following a direct perturbation during DS and SS. Future work should extend this novel direct knee perturbation paradigm to participants with unstable knees.","abstract_has_math":false,"creators":["Bakoc, Marija"],"institution":"University of Guelph","degree_name":"Master of Applied Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Brandon, Scott"],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023-08","date_published":"2023-08","updated_at":"2026-11-19T08:25:34Z","subjects":["biomechanics","knee","gait perturbations","wearable devices","instrumented knee brace"],"languages":["en"],"rights":["Attribution 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/27780","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/27780","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F27780","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F27780","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Brandon, Scott"]},{"key":"dc:creator","label":"Author","values":["Bakoc, Marija"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2023-08-31T13:24:17Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2023-08-31T13:24:17Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2023-08"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2023-07-14"]},{"key":"dc:date.issued","label":"Date","values":["2023-08"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["biomechanics","knee","gait perturbations","wearable devices","instrumented knee brace"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution 4.0 International"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://creativecommons.org/licenses/by/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10214/27780"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Knee instability has been extensively studied over the last decade as it limits mobility, increases the risk of falls, and leads to longer rehabilitation periods. To better understand the impact of knee instability on knee joint function, innovative research that challenges knee stability, beyond walking surface translations, is needed. This study aimed to validate a novel knee brace perturbation device that directly challenges the knee during gait. Eighteen healthy participants completed one walking trial as the brace delivered six single-perturbations in random order: three during double-limb support (DS), and three during single-limb support (SS). In the step during and the step after the perturbation, elevated neuromuscular responses were observed irrespective of the perturbation timing (DS versus SS). These results suggest that the knee is equally destabilized following a direct perturbation during DS and SS. Future work should extend this novel direct knee perturbation paradigm to participants with unstable knees."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["Ontario Graduate Scholarship","University of Guelph","Natural Sciences and Engineering Research Council of Canada"]},{"key":"dc:title","label":"Title","values":["A Novel Knee Brace Perturbation Device Tested on Healthy Control Subjects: Quantifying Perturbation Responses During Gait"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Brandon, Scott"],"dc:creator":["Bakoc, Marija"],"dc:date.accessioned":["2023-08-31T13:24:17Z"],"dc:date.available":["2023-08-31T13:24:17Z"],"dc:date.copyright":["2023-08"],"dc:date.created":["2023-07-14"],"dc:date.issued":["2023-08"],"dc:description.abstract":["Knee instability has been extensively studied over the last decade as it limits mobility, increases the risk of falls, and leads to longer rehabilitation periods. To better understand the impact of knee instability on knee joint function, innovative research that challenges knee stability, beyond walking surface translations, is needed. This study aimed to validate a novel knee brace perturbation device that directly challenges the knee during gait. Eighteen healthy participants completed one walking trial as the brace delivered six single-perturbations in random order: three during double-limb support (DS), and three during single-limb support (SS). In the step during and the step after the perturbation, elevated neuromuscular responses were observed irrespective of the perturbation timing (DS versus SS). These results suggest that the knee is equally destabilized following a direct perturbation during DS and SS. Future work should extend this novel direct knee perturbation paradigm to participants with unstable knees."],"dc:description.sponsorship":["Ontario Graduate Scholarship","University of Guelph","Natural Sciences and Engineering Research Council of Canada"],"dc:identifier.uri":["https://hdl.handle.net/10214/27780"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights":["Attribution 4.0 International"],"dc:rights.uri":["http://creativecommons.org/licenses/by/4.0/"],"dc:subject":["biomechanics","knee","gait perturbations","wearable devices","instrumented knee brace"],"dc:title":["A Novel Knee Brace Perturbation Device Tested on Healthy Control Subjects: Quantifying Perturbation Responses During Gait"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Applied Science"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:25:34Z"}