{"id":{"repo_id":"guelph","oai_identifier":"oai:atrium.lib.uoguelph.ca:10214/27879"},"canonical_url":"https://search.ndltd.org/etd/guelph/oai:atrium.lib.uoguelph.ca:10214/27879","repository":{"repo_id":"guelph","name":"University of Guelph","base_url":"https://atrium.lib.uoguelph.ca/server/oai/request"},"display":{"title":"Using Active Distributed Temperature Sensing to Evaluate Monitoring Interval and Seal Placement and Integrity of Backfilled Multilevel Systems","abstract":"The use of backfilled multilevel systems in fractured bedrock aquifers has proven useful for monitoring hydraulic head and groundwater quality at multiple depths within a single borehole. Placement of backfill material at the intended depths is important for achieving the desired monitoring interval position, yet perfect placement and seal integrity of these intervals can be challenging. It is important therefore to assess the final placement and condition of bentonite seals to provide accurate monitoring data. A new approach using fibre optic Active Distributed Temperature Sensing (A-DTS) with a composite fibre optic cable deployed in the annular space is presented as an effective tool for quantifying the position of monitoring intervals and identifying issues associated with backfilling. A-DTS data, analyzed in three bedrock boreholes with backfilled multilevel systems in the Guelph, ON area, demonstrates clear boundaries between backfill materials allowing assessment of their positioning and the continuity of the bentonite seals.","abstract_html":"The use of backfilled multilevel systems in fractured bedrock aquifers has proven useful for monitoring hydraulic head and groundwater quality at multiple depths within a single borehole. Placement of backfill material at the intended depths is important for achieving the desired monitoring interval position, yet perfect placement and seal integrity of these intervals can be challenging. It is important therefore to assess the final placement and condition of bentonite seals to provide accurate monitoring data. A new approach using fibre optic Active Distributed Temperature Sensing (A-DTS) with a composite fibre optic cable deployed in the annular space is presented as an effective tool for quantifying the position of monitoring intervals and identifying issues associated with backfilling. A-DTS data, analyzed in three bedrock boreholes with backfilled multilevel systems in the Guelph, ON area, demonstrates clear boundaries between backfill materials allowing assessment of their positioning and the continuity of the bentonite seals.","abstract_has_math":false,"creators":["Brown, Mitchell"],"institution":"University of Guelph","degree_name":"Master of Applied Science","degree_level":null,"degree_discipline":null,"degree_department":"School of Engineering","school":null,"contributors":[],"advisors":["Parker, Beth"],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:24:43Z","subjects":["active distributed temperature sensing","multilevel systems","backfill","high resolution"],"languages":["en"],"rights":["Attribution-NonCommercial 4.0 International"],"rights_urls":["https://creativecommons.org/licenses/by-nc/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10214/27879","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10214/27879","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aguelph%3Aoai%3Aatrium.lib.uoguelph.ca%3A10214%2F27879","prefix":"oai_dc"},"source_record":{"url":"https://atrium.lib.uoguelph.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aatrium.lib.uoguelph.ca%3A10214%2F27879","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Parker, Beth"]},{"key":"dc:creator","label":"Author","values":["Brown, Mitchell"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2023-09-11T15:48:03Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2023-09-11T15:48:03Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2023-09"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2023-07-19"]},{"key":"dc:publisher","label":"Institution","values":["University of Guelph"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["School of Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Guelph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["active distributed temperature sensing","multilevel systems","backfill","high resolution"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution-NonCommercial 4.0 International"]},{"key":"dc:rights.uri","label":"Rights URI","values":["https://creativecommons.org/licenses/by-nc/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10214/27879"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The use of backfilled multilevel systems in fractured bedrock aquifers has proven useful for monitoring hydraulic head and groundwater quality at multiple depths within a single borehole. Placement of backfill material at the intended depths is important for achieving the desired monitoring interval position, yet perfect placement and seal integrity of these intervals can be challenging. It is important therefore to assess the final placement and condition of bentonite seals to provide accurate monitoring data. A new approach using fibre optic Active Distributed Temperature Sensing (A-DTS) with a composite fibre optic cable deployed in the annular space is presented as an effective tool for quantifying the position of monitoring intervals and identifying issues associated with backfilling. A-DTS data, analyzed in three bedrock boreholes with backfilled multilevel systems in the Guelph, ON area, demonstrates clear boundaries between backfill materials allowing assessment of their positioning and the continuity of the bentonite seals."]},{"key":"dc:title","label":"Title","values":["Using Active Distributed Temperature Sensing to Evaluate Monitoring Interval and Seal Placement and Integrity of Backfilled Multilevel Systems"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Parker, Beth"],"dc:creator":["Brown, Mitchell"],"dc:date.accessioned":["2023-09-11T15:48:03Z"],"dc:date.available":["2023-09-11T15:48:03Z"],"dc:date.copyright":["2023-09"],"dc:date.created":["2023-07-19"],"dc:description.abstract":["The use of backfilled multilevel systems in fractured bedrock aquifers has proven useful for monitoring hydraulic head and groundwater quality at multiple depths within a single borehole. Placement of backfill material at the intended depths is important for achieving the desired monitoring interval position, yet perfect placement and seal integrity of these intervals can be challenging. It is important therefore to assess the final placement and condition of bentonite seals to provide accurate monitoring data. A new approach using fibre optic Active Distributed Temperature Sensing (A-DTS) with a composite fibre optic cable deployed in the annular space is presented as an effective tool for quantifying the position of monitoring intervals and identifying issues associated with backfilling. A-DTS data, analyzed in three bedrock boreholes with backfilled multilevel systems in the Guelph, ON area, demonstrates clear boundaries between backfill materials allowing assessment of their positioning and the continuity of the bentonite seals."],"dc:identifier.uri":["https://hdl.handle.net/10214/27879"],"dc:language.iso":["en"],"dc:publisher":["University of Guelph"],"dc:rights":["Attribution-NonCommercial 4.0 International"],"dc:rights.uri":["https://creativecommons.org/licenses/by-nc/4.0/"],"dc:subject":["active distributed temperature sensing","multilevel systems","backfill","high resolution"],"dc:title":["Using Active Distributed Temperature Sensing to Evaluate Monitoring Interval and Seal Placement and Integrity of Backfilled Multilevel Systems"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["School of Engineering"],"thesis:degree_name":["Master of Applied Science"],"thesis:degree_program":["Engineering"],"thesis:institution_name":["University of Guelph"]},"updated_at":"2026-11-19T08:24:43Z"}